JACC Cardiovasc Interv ; 7(6): 688-95, 2014 Jun.
Article in English | MEDLINE | ID: mdl-24835327

ABSTRACT

OBJECTIVES: Using intravascular ultrasound (IVUS) and histomorphometry, this study sought to evaluate the potential of nonatherosclerotic porcine coronary arteries to undergo progressive lumen gain and a return of pulsatility after implantation with an everolimus-eluting bioresorbable vascular scaffold (BVS). BACKGROUND: Unique benefits such as lumen gain and restored vasomotion have been demonstrated clinically after treatment with BVS; however, a more rigorous demonstration of these benefits with a randomized clinical trial has not yet been conducted. METHODS: Seventy nonatherosclerotic swine received 109 everolimus-eluting BVS and 70 everolimus-eluting metal stents randomized among the main coronary arteries. Arteries were evaluated in vivo by angiography and IVUS and post-mortem by histomorphometry at time points from 1 to 42 months. RESULTS: From 1 to 6 months, both BVS- and everolimus-eluting metal stent-implanted arteries demonstrated stable lumen areas (LAs). From 12 months to 42 months, there was a progressive increase in the LA of arteries implanted with a BVS as assessed by histomorphometry and IVUS. This lumen gain in the implanted segment corresponded to an increase in the reference vessel LA. Normalization in the in-segment LA (LA:reference vessel LA) was observed qualitatively by angiography and quantitatively by IVUS. Additionally, BVS-implanted arteries demonstrated restored in-segment pulsatility on the basis of IVUS assessment of the differences in the mid-scaffold area between end-diastole to end-systole. CONCLUSIONS: Starting at 12 months, BVS-implanted porcine coronary arteries underwent progressive lumen gain and showed restored pulsatility. These benefits demonstrated preclinically may translate into improvements in long-term clinical outcomes for patients treated with BVS compared with conventional drug-eluting stents.


Subject(s)
Absorbable Implants , Coronary Artery Disease/surgery , Coronary Circulation/physiology , Coronary Vessels/surgery , Pulsatile Flow , Tissue Scaffolds , Animals , Coronary Angiography , Coronary Artery Disease/diagnosis , Coronary Artery Disease/physiopathology , Coronary Vessels/diagnostic imaging , Coronary Vessels/physiopathology , Disease Models, Animal , Drug-Eluting Stents , Prosthesis Design , Swine , Ultrasonography, Interventional/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...