Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Language
Publication year range
1.
Rev. cuba. med ; 49(3): 288-295, jul.-sep. 2010.
Article in Spanish | LILACS | ID: lil-584791

ABSTRACT

A pesar de las mejoras desarrolladas en el diseño de las prótesis valvulares mecánicas, la trombosis valvular protésica continúa siendo una causa frecuente de morbilidad, generalmente por una anticoagulación incorrecta. Se presentó una paciente con trombosis protésica mitral al año de su implantación, que recibió un diagnóstico imaginológico mediante ecocardiografía transtorácica, transesofágica y tomografía computarizada de 64 cortes. La terapia trombolítica fue exitosa y permitió la evolución satisfactoria de la paciente.


Despite the progress achieved in the design of mechanical prosthetic valves, prosthetic valve thrombosis remains a frequent cause of morbidity, usually due to incorrect anticoagulation. A patient was presented with mitral prosthetic thrombosis one year after implantation, who had been diagnosed by transthoracic transesophageal echocardiography imaging and 64-slice computed tomography. Thrombolytic therapy was successful and led to the satisfactory evolution of the patient.

2.
in Spanish | CUMED | ID: cum-4952749527

ABSTRACT

A pesar de las mejoras desarrolladas en el diseño de las prótesis valvulares mecánicas, la trombosis valvular protésica continúa siendo una causa frecuente de morbilidad, generalmente por una anticoagulación incorrecta. Se presentó una paciente con trombosis protésica mitral al año de su implantación, que recibió un diagnóstico imaginológico mediante ecocardiografía transtorácica, transesofágica y tomografía computarizada de 64 cortes. La terapia trombolítica fue exitosa y permitió la evolución satisfactoria de la paciente(AU)


A pesar de las mejoras desarrolladas en el diseño de las prótesis valvulares mecánicas, la trombosis valvular protésica continúa siendo una causa frecuente de morbilidad, generalmente por una anticoagulación incorrecta. Se presentó una paciente con trombosis protésica mitral al año de su implantación, que recibió un diagnóstico imaginológico mediante ecocardiografía transtorácica, transesofágica y tomografía computarizada de 64 cortes. La terapia trombolítica fue exitosa y permitió la evolución satisfactoria de la paciente(AU)


Despite the progress achieved in the design of mechanical prosthetic valves, prosthetic valve thrombosis remains a frequent cause of morbidity, usually due to incorrect anticoagulation. A patient was presented with mitral prosthetic thrombosis one year after implantation, who had been diagnosed by transthoracic transesophageal echocardiography imaging and 64-slice computed tomography. Thrombolytic therapy was successful and led to the satisfactory evolution of the patient(AU)


Despite the progress achieved in the design of mechanical prosthetic valves, prosthetic valve thrombosis remains a frequent cause of morbidity, usually due to incorrect anticoagulation. A patient was presented with mitral prosthetic thrombosis one year after implantation, who had been diagnosed by transthoracic transesophageal echocardiography imaging and 64-slice computed tomography. Thrombolytic therapy was successful and led to the satisfactory evolution of the patient(AU)


Subject(s)
Female , Middle Aged , Female , Middle Aged , Heart Valve Prosthesis Implantation/adverse effects , Mitral Valve/physiopathology , Heart Valve Prosthesis Implantation/adverse effects , Mitral Valve/physiopathology , Thrombolytic Therapy , Echocardiography, Transesophageal , Echocardiography , Thrombolytic Therapy , Echocardiography, Transesophageal , Echocardiography
3.
CorSalud ; 2(1)mar. 2010. ilus
Article in Spanish | CUMED | ID: cum-44346

ABSTRACT

Los resultados de la reanimación cardiopulmonar en el paro cardíaco extrahospitalario son poco satisfactorios en los mejores centros asistenciales del mundo, con un porcentaje de supervivientes muy bajo. El tema constituye en la actualidad un desafío para los médicos de asistencia; para otros, una asignatura pendiente. En este artículo presentamos el caso de una paciente con muerte súbita, producida por un infarto agudo de miocardio anterior extenso, asistida y recuperada por su médico de familia y por especialistas del Instituto de Cardiología y Cirugía Cardiovascular(AU)


Subject(s)
Humans , Female , Adult , Death, Sudden, Cardiac , Myocardial Infarction , Heart Arrest
SELECTION OF CITATIONS
SEARCH DETAIL
...