Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 28
Filter
6.
JACC Case Rep ; 4(15): 990-995, 2022 Aug 03.
Article in English | MEDLINE | ID: mdl-35935156

ABSTRACT

A woman with recurrent presyncope caused by a functional atrioventricular (AV) block after meals, with limiting symptoms, underwent cardioneuroablation and AV node vagal denervation without pacemaker implantation. Normal AV conduction was recovered with complete abolishment of symptoms. (Level of Difficulty: Advanced.).

7.
JACC. Case reports ; 4(15): 990-995, Aug. 2022. ilus
Article in English | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1381615

ABSTRACT

ABSTRACT: A woman with recurrent presyncope caused by a functional atrioventricular (AV) block after meals, with limiting symptoms, underwent cardioneuroablation and AV node vagal denervation without pacemaker implantation. Normal AV conduction was recovered with complete abolishment of symptoms.


Subject(s)
Humans , Female , Atrioventricular Node , Denervation , Atrioventricular Block , Syncope
10.
Circ Arrhythm Electrophysiol ; 13(12): 1-32, Dec. 2020. tab, ilus, graf
Article in English | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1150474

ABSTRACT

ABSTRACT: Several disorders present reflex or persistent increase in vagal tone that may cause refractory symptoms even in a normal heart patient. Cardioneuroablation (CNA), the vagal denervation by RF ablation of the neuromyocardial interface, was developed to treat these conditions without pacemaker implantation. A theoretical limitation could be the reinnervation, that naturally grows in the first year, that could recover the vagal hyperactivity. This study aims to verify the vagal denervation degree in the chronic phase after CNA. Additionally, it intends to investigate the arrhythmias behavior after CNA. METHODS - prospective longitudinal study with intra-patient comparison of 83 very symptomatic cases without significant cardiopathy, submitted to CNA, 49(59%) male, 47.3±17 years-old, having vagal paroxysmal atrial fibrillation 58(70%) or neurocardiogenic syncope 25(30%), NYHA Class < II and absence of significant comorbidities. CNA was performed in both atria by interatrial septum puncture, with irrigated conventional catheter and electroanatomic reconstruction. Ablation targeted the neuromiocardial interface by fragmentation mapping (AFNests) using the Velocity Fractionation software, conventional recording and anatomical localization of the ganglionated plexi. There were compared the time and frequency domain of the heart rate variability (HRV) and arrhythmias in 24h Holter pre-, 1-year-post- and 2-year-postCNA. Clinical outpatient follow-up and serial Holter showed 80% asymptomatic cases at 40 months. RESULTS - Time and frequency domain HRV demonstrated significant decrease in all autonomic parameters, showing an important parasympathetic and sympathetic activity reduction at 2 yearspost-CNA (p0.05) suggesting that the reinnervation has halted. There was also an important reduction in all brady- and tachyarrhythmias pre- vs. post-CNA, (p<0.01). CONCLUSIONS ­ There is an important and significant vagal and sympathetic denervation after 2 years of CAN with a significant reduction in brady and tachyarrhythmia in the whole group. There were no complications.


Subject(s)
Sympathectomy , Electrocardiography, Ambulatory , Syncope, Vasovagal
11.
Circ Arrhythm Electrophysiol ; 13(12): e008703, 2020 12.
Article in English | MEDLINE | ID: mdl-33198486

ABSTRACT

BACKGROUND: Several disorders present reflex or persistent increase in vagal tone that may cause refractory symptoms even in a normal heart patient. Cardioneuroablation, the vagal denervation by radiofrequency ablation of the neuromyocardial interface, was developed to treat these conditions without pacemaker implantation. A theoretical limitation could be the reinnervation, that naturally grows in the first year, that could recover the vagal hyperactivity. This study aims to verify the vagal denervation degree in the chronic phase after cardioneuroablation. Additionally, it intends to investigate the arrhythmias behavior after cardioneuroablation. METHODS: Prospective longitudinal study with intrapatient comparison of 83 very symptomatic cases without significant cardiopathy, submitted to cardioneuroablation, 49 (59%) male, 47.3±17 years old, having vagal paroxysmal atrial fibrillation 58 (70%) or neurocardiogenic syncope 25 (30%), New York Heart Association class0.05) suggesting that the reinnervation has halted. There was also an important reduction in all bradyarrhythmias and tachyarrhythmias pre-cardioneuroablation versus post-cardioneuroablation (P<0.01). CONCLUSIONS: There is an important and significant vagal and sympathetic denervation after 2 years of cardioneuroablation with a significant reduction in bradyarrhythmia and tachyarrhythmia in the whole group. There were no complications.


Subject(s)
Atrial Fibrillation/surgery , Catheter Ablation , Electrocardiography, Ambulatory , Heart Rate , Heart/innervation , Syncope, Vasovagal/surgery , Vagotomy , Vagus Nerve/surgery , Adolescent , Adult , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Catheter Ablation/adverse effects , Female , Humans , Longitudinal Studies , Male , Middle Aged , Predictive Value of Tests , Prospective Studies , Recurrence , Risk Factors , Sympathetic Nervous System/physiopathology , Syncope, Vasovagal/diagnosis , Syncope, Vasovagal/physiopathology , Time Factors , Treatment Outcome , Vagotomy/adverse effects , Vagus Nerve/physiopathology , Young Adult
13.
Arq. bras. cardiol ; 113(2 supl.1): 18-18, set., 2019.
Article in Portuguese | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1021296

ABSTRACT

Confirmar se a condução ventrículoatrial [CVA] ocorre por via normal ou anômala [VA] é fundamental no diagnóstico e ablação [ABL] de taquicardias supraventriculares [TSV]. Neste estudo propomos uma alternativa de confirmar a presença de VAs ocultas, através da estimulação vagal extracardíaca [EVEC] considerando que esta bloqueia a condução pelo nó AV. MÉTODOS: 26 pcts, 27,9±15anos, 15(57,7%) sexo feminino, portadores de TSV: reentrada nodal [RN] 5(19%) e reentrada AV [RAV] 21(81%) com ou sem pré-excitação, submetidos à ABL por RF. A partir da punção femoral e veias jugulares internas D ou E, um cateter foi avançado até o nível do maxilar superior para EVEC(30Hz/50µs/0,5 a 1V/kg até 70V) sem contato com o vago. A CVA foi testada com e sem EVEC durante estimulação ventricular[EV], pré e pós-ABL. RESULTADOS: Em todos os casos, foi possível obter intensa ação vagal com supressão reversível do nó sinusal e nó AV. Antes da ABL, a CVA estava presente em todos os casos e foi bloqueada pela EVEC apenas nos casos sem VAs. Após a ABL, a CVA foi completamente bloqueada pela EVEC em todos os casos, mas reapareceu em um pct de RN. Em todos pct de RAV, a CVA não foi bloqueada pela EVEC pré-ABL, mas desapareceu ou foi bloqueada pela EVEC pós-ABL (tabela). CONCLUSÃO: O bloqueio da CVA por EVEC sugere ausência ou eliminação com sucesso de vias anômalas. O ressurgimento da CVA resistente à EVEC pós-ABL em uma RN pode ser explicado pela denervação nodal AV pela ABL do 3º gânglio cardíaco durante ABL da via lenta. Estes dados sugerem que a EVEC pode ser muito útil para revelar VAs anômalas septais difíceis que se confundem com a CVA por vias normais. (AU)


Subject(s)
Humans , Tachycardia, Supraventricular , Catheter Ablation
14.
J Atr Fibrillation ; 10(2): 1583, 2017.
Article in English | MEDLINE | ID: mdl-29250230

ABSTRACT

BACKGROUND: Catheter ablation of long-standing persistent AF (LSAF) remains challenging. Since AF-Nest (AFN) description, we have observed that a stable, protected, fast source firing, namely "Background Tachycardia"(BT), could be hidden beneath the chaotic AF. Following pulmonary vein isolation (PVI)+AFN ablation one or more BT may arise or be induced in 30-40% of patients, which could be the culprit forAF maintenance and ablation recurrences. METHODS AND RESULTS: We studied 114 patients, from 322 sequential LSAF regular ablations, having spontaneous or induced residual BT after EGM-guided PVI+AFN ablation of LSAF; 55.6±11y/o, 97males (85.1%), EF=65.5±8%, LA=42.8±6.7mm. Macroreentrant tachycardias were excluded. Pre-ablationAF 12-leads ECG Digital processing(DP) and spectral analysis(SA) was performed searching for BT before AF ablation and its correlation with BT during ablation.After PVI, 38.1±9 AFN sites/patient and 135 sustained BTs (1-3, 1.2±0.5/patient) were ablated. BT cycle length(CL) was 246.3±37.3ms. In 79 patients presenting suitable DP for SA, the BT-CL was 241.6±34.3ms with intra procedure BT-CL correlation r=0.83/p<0.01. Following BT ablation, AF could not be induced. During FU of 13→60 months(22.8±12m), AF freedom for BT RF(+) vs. BT RF(-) groups were 77.9% vs. 56.4% (p=0.009), respectively. There was no significant complication. CONCLUSION: BT ablation following PVI and AFN ablation improved long-term outcomes ofLSAF ablation. BT is likely due to sustained microreentry, protected during AF by entry block. BT can be suspected by spectral analysis of the pre-ablation ECG and is likely one important AF perpetuator by causing electrical resonance of the AFN. This ablation strategy warrants randomized, multicenter investigation.

15.
RELAMPA, Rev. Lat.-Am. Marcapasso Arritm ; 30(4): f:157-l:161, out.-dez. 2017. ilus
Article in Portuguese | LILACS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-879944

ABSTRACT

A fibrilação atrial é a arritmia sustentada mais frequente na prática clínica. Uma significativa parcela de pacientes portadores dessa afecção evolui com períodos de bradiarritmias, necessitando implante de marcapasso. Dessa forma, nos portadores de dispositivos cardíacos implantáveis, pode ser necessária a indicação de ablações complexas, como a da fibrilação atrial, com acesso transeptal e manipulação de cateteres próximo aos cabos-eletrodos definitivos. Relatamos o caso de um paciente portador de marcapasso bicameral com síndrome bradi-taquicardia e fibrilação atrial de alta frequência ventricular, refratária à medicação, no qual foi possível realizar a ablação da fibrilação atrial com sucesso a longo prazo, demonstrado pela telemetria do marcapasso, permitindo suspender a anticoagulação e sem necessidade de indicar bloqueio atrioventricular


Atrial fibrillation is the most frequent sustained cardiac arrhythmia in the clinical practice. A significant number of patients with this pathology may present periods of bradyarrhythmia requiring pacemaker implantation. Thus, in patients with implantable cardiac devices, complex ablations may be required, such as in atrial fibrillation, requiring transeptal access and handling of catheters near the definitive leads. We report the case of a patient with a dual-chamber pacemaker with brady-tachy syndrome and atrial fibrillation with high ventricular rate, refractory to medication, in whom it was possible to perform ablation of atrial fibrillation with long-term success demonstrated by pacemaker telemetry, allowing anticoagulation to be discontinued, avoiding atrioventricular block


Subject(s)
Humans , Male , Middle Aged , Pacemaker, Artificial , Radio Waves , Atrial Fibrillation , Bradycardia , Catheter Ablation , Arrhythmias, Cardiac/diagnosis , Pulmonary Veins , Body Mass Index , Risk Factors , Treatment Outcome , Echocardiography, Transesophageal/methods , Electrodes , Neoplasms/surgery
16.
Rev Bras Cir Cardiovasc ; 30(2): 139-47, 2015.
Article in English | MEDLINE | ID: mdl-26107444

ABSTRACT

INTRODUCTION: Although rare, the atrioesophageal fistula is one of the most feared complications in radiofrequency catheter ablation of atrial fibrillation due to the high risk of mortality. OBJECTIVE: This is a prospective controlled study, performed during regular radiofrequency catheter ablation of atrial fibrillation, to test whether esophageal displacement by handling the transesophageal echocardiography transducer could be used for esophageal protection. METHODS: Seven hundred and four patients (158 F/546M [22.4%/77.6%]; 52.8 ± 14 [17-84] years old), with mean EF of 0.66 ± 0.8 and drug-refractory atrial fibrillation were submitted to hybrid radiofrequency catheter ablation (conventional pulmonary vein isolation plus AF-Nests and background tachycardia ablation) with displacement of the esophagus as far as possible from the radiofrequency target by transesophageal echocardiography transducer handling. The esophageal luminal temperature was monitored without and with displacement in 25 patients. RESULTS: The mean esophageal displacement was 4 to 9.1cm (5.9 ± 0.8 cm). In 680 of the 704 patients (96.6%), it was enough to allow complete and safe radiofrequency delivery (30W/40ºC/irrigated catheter or 50W/60ºC/8 mm catheter) without esophagus overlapping. The mean esophageal luminal temperature changes with versus without esophageal displacement were 0.11 ± 0.13ºC versus 1.1 ± 0.4ºC respectively, P<0.01. The radiofrequency had to be halted in 68% of the patients without esophageal displacement because of esophageal luminal temperature increase. There was no incidence of atrioesophageal fistula suspected or confirmed. Only two superficial bleeding caused by transesophageal echocardiography transducer insertion were observed. CONCLUSION: Mechanical esophageal displacement by transesophageal echocardiography transducer during radiofrequency catheter ablation was able to prevent a rise in esophageal luminal temperature, helping to avoid esophageal thermal lesion. In most cases, the esophageal displacement was sufficient to allow safe radiofrequency application without esophagus overlapping, being a convenient alternative in reducing the risk of atrioesophageal fistula.


Subject(s)
Atrial Fibrillation/surgery , Cardiomyopathies/prevention & control , Catheter Ablation/adverse effects , Catheter Ablation/methods , Esophageal Fistula/prevention & control , Fistula/prevention & control , Adolescent , Adult , Aged , Aged, 80 and over , Atrial Fibrillation/diagnostic imaging , Cardiomyopathies/etiology , Catheter Ablation/instrumentation , Echocardiography, Transesophageal/instrumentation , Esophageal Fistula/etiology , Esophagus/anatomy & histology , Esophagus/diagnostic imaging , Esophagus/injuries , Female , Fistula/etiology , Heart Atria/diagnostic imaging , Heart Atria/surgery , Humans , Male , Middle Aged , Prospective Studies , Reproducibility of Results , Risk Factors , Temperature , Treatment Outcome , Young Adult
17.
Rev. bras. cir. cardiovasc ; 30(2): 139-147, Mar-Apr/2015. tab, graf
Article in English | LILACS, Sec. Est. Saúde SP | ID: lil-748943

ABSTRACT

Abstract Introduction: Although rare, the atrioesophageal fistula is one of the most feared complications in radiofrequency catheter ablation of atrial fibrillation due to the high risk of mortality. Objective: This is a prospective controlled study, performed during regular radiofrequency catheter ablation of atrial fibrillation, to test whether esophageal displacement by handling the transesophageal echocardiography transducer could be used for esophageal protection. Methods: Seven hundred and four patients (158 F/546M [22.4%/77.6%]; 52.8±14 [17-84] years old), with mean EF of 0.66±0.8 and drug-refractory atrial fibrillation were submitted to hybrid radiofrequency catheter ablation (conventional pulmonary vein isolation plus AF-Nests and background tachycardia ablation) with displacement of the esophagus as far as possible from the radiofrequency target by transesophageal echocardiography transducer handling. The esophageal luminal temperature was monitored without and with displacement in 25 patients. Results: The mean esophageal displacement was 4 to 9.1cm (5.9±0.8 cm). In 680 of the 704 patients (96.6%), it was enough to allow complete and safe radiofrequency delivery (30W/40ºC/irrigated catheter or 50W/60ºC/8 mm catheter) without esophagus overlapping. The mean esophageal luminal temperature changes with versus without esophageal displacement were 0.11±0.13ºC versus 1.1±0.4ºC respectively, P<0.01. The radiofrequency had to be halted in 68% of the patients without esophageal displacement because of esophageal luminal temperature increase. There was no incidence of atrioesophageal fistula suspected or confirmed. Only two superficial bleeding caused by transesophageal echocardiography transducer insertion were observed. Conclusion: Mechanical esophageal displacement by transesophageal echocardiography transducer during radiofrequency catheter ablation was able to prevent a rise in esophageal luminal temperature, helping to avoid ...


Resumo Introdução: Apesar de rara, a fístula átrio-esofágica é uma das complicações mais temidas na ablação por radiofrequência da fibrilação atrial pelo alto risco de mortalidade. Objetivo: Este é um estudo prospectivo controlado, realizado durante a ablação por radiofrequência da fibrilação atrial regular, para testar se o deslocamento do esôfago ao manipular o transdutor de ecocardiografia transesofágica poderia ser usado para a proteção de esôfago. Métodos: Setecentos e quatro pacientes (158 mulheres e 546 homens [22,4%/77,6%]; 52,8±14 [17-84] anos), com EF média igual a 0,66±0,8 e com fibrilação atrial refratária ao tratamento medicamentoso, foram submetidos à terapia híbrida com ablação por radiofrequência (isolamento convencional das veias pulmonares e ninhos de fibrilação atrial e ablação de taquicardia de background) com deslocamento do esôfago o mais longe possível do alvo da radiofrequência por manuseio do transdutor de ecocardiografia transesofágica. A temperatura luminal esofágica foi monitorada com e sem deslocamento em 25 pacientes. Resultados: O deslocamento esofágico significativo foi de 4 a 9,1 centímetros (5,9±0,8 cm). Em 680 dos 704 pacientes (96,6%), isso foi o suficiente para permitir a entrega completa e segura de radiofrequência (30W/40ºC/cateter irrigado ou 50W/60ºC/cateter de 8 milímetros) sem sobreposição do esôfago. As alterações médias de temperatura luminal esofágica com e sem deslocamento de esôfago foram de 0,11±0,13ºC versus 1,1±0,4ºC, respectivamente, P<0,01. A radiofrequência teve que ser interrompida em 68% dos pacientes sem deslocamento de esôfago devido ao aumento da temperatura luminal esofágica. Não houve nenhum caso, suspeito ou confirmado, de fístula átrio-esofágica. Foram observados apenas dois sangramentos superficiais causados por inserção do transdutor de ecocardiografia transesofágica. Conclusão: O deslocamento mecânico do esôfago pelo transdutor de ecocardiografia transesofágico durante ...


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Aged , Aged, 80 and over , Young Adult , Atrial Fibrillation/surgery , Cardiomyopathies/prevention & control , Catheter Ablation/adverse effects , Catheter Ablation/methods , Esophageal Fistula/prevention & control , Fistula/prevention & control , Atrial Fibrillation , Cardiomyopathies/etiology , Catheter Ablation/instrumentation , Echocardiography, Transesophageal/instrumentation , Esophageal Fistula/etiology , Esophagus/anatomy & histology , Esophagus/injuries , Esophagus , Fistula/etiology , Heart Atria/surgery , Heart Atria , Prospective Studies , Reproducibility of Results , Risk Factors , Temperature , Treatment Outcome
18.
Arq. bras. cardiol ; 104(1): 45-52, 01/2015. tab, graf
Article in English | LILACS, Sec. Est. Saúde SP | ID: lil-741127

ABSTRACT

Background: Heart failure and atrial fibrillation (AF) often coexist in a deleterious cycle. Objective: To evaluate the clinical and echocardiographic outcomes of patients with ventricular systolic dysfunction and AF treated with radiofrequency (RF) ablation. Methods: Patients with ventricular systolic dysfunction [ejection fraction (EF) <50%] and AF refractory to drug therapy underwent stepwise RF ablation in the same session with pulmonary vein isolation, ablation of AF nests and of residual atrial tachycardia, named "background tachycardia". Clinical (NYHA functional class) and echocardiographic (EF, left atrial diameter) data were compared (McNemar test and t test) before and after ablation. Results: 31 patients (6 women, 25 men), aged 37 to 77 years (mean, 59.8±10.6), underwent RF ablation. The etiology was mainly idiopathic (19 p, 61%). During a mean follow-up of 20.3±17 months, 24 patients (77%) were in sinus rhythm, 11 (35%) being on amiodarone. Eight patients (26%) underwent more than one procedure (6 underwent 2 procedures, and 2 underwent 3 procedures). Significant NYHA functional class improvement was observed (pre-ablation: 2.23±0.56; postablation: 1.13±0.35; p<0.0001). The echocardiographic outcome also showed significant ventricular function improvement (EF pre: 44.68%±6.02%, post: 59%±13.2%, p=0.0005) and a significant left atrial diameter reduction (pre: 46.61±7.3 mm; post: 43.59±6.6 mm; p=0.026). No major complications occurred. Conclusion: Our findings suggest that AF ablation in patients with ventricular systolic dysfunction is a safe and highly effective procedure. Arrhythmia control has a great impact on ventricular function recovery and functional class improvement. .


Fundamento: Insuficiência cardíaca e fibrilação atrial (FA) frequentemente coexistem em um ciclo deletério. Objetivo: Avaliar a evolução clínica e ecocardiográfica de portadores de disfunção ventricular e FA tratados com ablação por radiofrequência (RF). Métodos: Portadores de disfunção sistólica [fração de ejeção (FE) < 50%] e FA rebelde a tratamento clínico foram submetidos à ablação por RF escalonada em três etapas na mesma sessão com isolamento das veias pulmonares, ablação dos ninhos de FA, pesquisa e ablação de taquicardias atriais e "taquicardia de background". Os dados clínicos (classe funcional da NYHA) e ecocardiográficos (FE; diâmetro do átrio esquerdo) pré- e pós-procedimento foram comparados (teste de McNemar e teste t, respectivamente). Resultados: 31 pacientes (6 mulheres, 25 homens) de 37 a 77 anos (média, 59,8 ± 11 anos) foram submetidos à ablação por RF. A cardiopatia foi predominantemente idiopática (19 p; 61%). Na evolução média de 20,3 ± 17 meses, 24 pacientes (77%) estavam em ritmo sinusal, sendo 11 (35%) com amiodarona. Oito pacientes (26%) foram submetidos a mais de um procedimento (6 submetidos a 2 procedimentos e 2 a 3 procedimentos). Observou-se melhora expressiva da classe funcional da NYHA (pré-ablação: 2,23 ± 0,56; pós: 1,13 ± 0,35; p < 0,0001). A avaliação ecocardiográfica evolutiva também mostrou melhora significativa da função ventricular (FE pré: 44,68% ± 6,02%; pós: 59% ± 13,2%; p = 0,0005) e redução significativa no diâmetro do átrio esquerdo (pré: 46,61 ± 7,3 mm; pós: 43,59 ± 6,6 mm; p = 0,026). Não ocorreram complicações maiores. Conclusão: Os resultados deste estudo sugerem que ablação de FA em portadores de disfunção ventricular seja um procedimento seguro e com eficácia elevada a médio prazo. O controle da arritmia tem grande impacto na recuperação da função ventricular e na melhora clínica avaliada pela classe funcional. .


Subject(s)
Adult , Aged , Female , Humans , Male , Middle Aged , Atrial Fibrillation/surgery , Catheter Ablation/methods , Heart Failure, Systolic/surgery , Ventricular Dysfunction/surgery , Atrial Fibrillation/physiopathology , Atrial Fibrillation , Echocardiography, Transesophageal , Electrocardiography , Heart Atria/physiopathology , Heart Atria , Heart Failure, Systolic/physiopathology , Heart Failure, Systolic , Retrospective Studies , Statistics, Nonparametric , Stroke Volume/physiology , Time Factors , Treatment Outcome , Ventricular Dysfunction/physiopathology , Ventricular Dysfunction
19.
Arq Bras Cardiol ; 104(1): 45-52, 2015 Jan.
Article in English, Portuguese | MEDLINE | ID: mdl-25387404

ABSTRACT

BACKGROUND: Heart failure and atrial fibrillation (AF) often coexist in a deleterious cycle. OBJECTIVE: To evaluate the clinical and echocardiographic outcomes of patients with ventricular systolic dysfunction and AF treated with radiofrequency (RF) ablation. METHODS: Patients with ventricular systolic dysfunction [ejection fraction (EF) <50%] and AF refractory to drug therapy underwent stepwise RF ablation in the same session with pulmonary vein isolation, ablation of AF nests and of residual atrial tachycardia, named "background tachycardia". Clinical (NYHA functional class) and echocardiographic (EF, left atrial diameter) data were compared (McNemar test and t test) before and after ablation. RESULTS: 31 patients (6 women, 25 men), aged 37 to 77 years (mean, 59.8 ± 10.6), underwent RF ablation. The etiology was mainly idiopathic (19 p, 61%). During a mean follow-up of 20.3 ± 17 months, 24 patients (77%) were in sinus rhythm, 11 (35%) being on amiodarone. Eight patients (26%) underwent more than one procedure (6 underwent 2 procedures, and 2 underwent 3 procedures). Significant NYHA functional class improvement was observed (pre-ablation: 2.23 ± 0.56; postablation: 1.13 ± 0.35; p < 0.0001). The echocardiographic outcome also showed significant ventricular function improvement (EF pre: 44.68% ± 6.02%, post: 59% ± 13.2%, p = 0.0005) and a significant left atrial diameter reduction (pre: 46.61 ± 7.3 mm; post: 43.59 ± 6.6 mm; p = 0.026). No major complications occurred. CONCLUSION: Our findings suggest that AF ablation in patients with ventricular systolic dysfunction is a safe and highly effective procedure. Arrhythmia control has a great impact on ventricular function recovery and functional class improvement.


Subject(s)
Atrial Fibrillation/surgery , Catheter Ablation/methods , Heart Failure, Systolic/surgery , Ventricular Dysfunction/surgery , Adult , Aged , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/physiopathology , Echocardiography, Transesophageal , Electrocardiography , Female , Heart Atria/diagnostic imaging , Heart Atria/physiopathology , Heart Failure, Systolic/diagnostic imaging , Heart Failure, Systolic/physiopathology , Humans , Male , Middle Aged , Retrospective Studies , Statistics, Nonparametric , Stroke Volume/physiology , Time Factors , Treatment Outcome , Ventricular Dysfunction/diagnostic imaging , Ventricular Dysfunction/physiopathology
20.
In. Timerman, Ari; Sousa, Amanda Guerra de Moraes Rego; Fragata Filho, Abilio Augusto; Armaganijan, Dikran; Bertolami, Marcelo Chiara; Meneghelo, Romeu Sergio. Condutas terapêuticas do Instituto Dante Pazzanese de Cardiologia. São Paulo, Atheneu, 2 ed; 2014. p.993-1006, ilus, tab.
Monography in Portuguese | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1082080
SELECTION OF CITATIONS
SEARCH DETAIL
...