Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Innovations (Phila) ; 16(3): 273-279, 2021.
Article in English | MEDLINE | ID: mdl-33866845

ABSTRACT

OBJECTIVE: To report early and midterm results registry of patients undergoing repeated aortic valve replacement (RAVR) with sutureless prostheses from an international prospective registry (SURE-AVR). METHODS: Between March 2011 and June 2019, 69 patients underwent RAVR with self-expandable sutureless aortic bioprostheses at 22 international cardiac centers. RESULTS: Overall mortality was 2.9% with a predicted logistic EuroSCORE II of 10.7%. Indications for RAVR were structural valve dysfunction (84.1%) and infective prosthetic endocarditis (15.9%) and were performed in patients with previously implanted bioprostheses (79.7%), mechanical valves (15.9%), and transcatheter valves (4.3%). Minimally invasive approach was performed in 15.9% of patients. Rate of stroke was 1.4% and rate of early valve-related reintervention was 1.4%. Overall survival rate at 1 and 5 years was 97% and 91%, respectively. No major paravalvular leak occurred. Rate of pacemaker implantation was 5.8% and 0.9% per patient-year early and at follow-up, respectively. The mean transvalvular gradient at 1-year and 5-year follow-up was 10.5 mm Hg and 11.5 mm Hg with a median effective orifice area of 1.8 cm2and 1.8 cm2, respectively. CONCLUSIONS: RAVR with sutureless valves is a safe and effective approach and provides excellent clinical and hemodynamic results up to 5 years.


Subject(s)
Aortic Valve Stenosis , Bioprosthesis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Humans , Prosthesis Design , Registries , Treatment Outcome
2.
Eur J Cardiothorac Surg ; 57(3): 496-503, 2020 03 01.
Article in English | MEDLINE | ID: mdl-31651944

ABSTRACT

OBJECTIVES: Both off-pump coronary artery bypass grafting surgery (OPCABG) and mini-extracorporeal circulation (MECC) have been associated with lower morbidity and mortality and less inflammation than conventional cardiopulmonary bypass. However, studies comparing the 2 techniques are scarce and the results are controversial. We compared the clinical outcomes and inflammatory response of low-risk patients undergoing coronary bypass grafting with MECC versus OPCABG. METHODS: We conducted a prospective, randomized study in patients undergoing coronary heart surgery. Two hundred and thirty consecutive low-risk patients were randomly assigned to either receive OPCABG (n = 117) or MECC (n = 113). Clinical outcomes and postoperative biochemical results were analysed in both groups. We also analysed 19 circulating inflammatory markers in a subgroup of 40 patients at 4 perioperative time points. The area under the curve for each marker was calculated to monitor differences in the inflammatory response. RESULTS: No significant differences were found between groups regarding perioperative clinical complications and no deaths occurred during the trial. Plasma levels in 9 of the 19 inflammatory markers were undetectable or showed no temporal variation, 3 were higher in the MECC group [interleukin (IL)-10, macrophage inflammatory protein-1ß and epidermal growth factor] and 7 were higher in the OPCABG group (growth regulator oncogene, IL-6, IL-8, soluble CD40 ligand, monocyte chemoattractant protein-1, monocyte chemoattractant protein-3 and tumour necrosis factor-α). Differences in 2 proinflammatory cytokines, IL-6 and monocyte chemoattractant protein 1, between the 2 surgical procedures were statistically significant. CONCLUSIONS: No clinical differences were observed between in low-risk patients undergoing MECC or OPCABG surgery, but OPCABG was associated with an increased release of proinflammatory cytokines compared with MECC. Studies in larger cohorts and in patients at higher risk are needed to confirm these findings. CLINICAL TRIAL REGISTRATION NUMBER: NCT02118025.


Subject(s)
Coronary Artery Bypass, Off-Pump , Extracorporeal Circulation , Coronary Artery Bypass/adverse effects , Coronary Artery Bypass, Off-Pump/adverse effects , Extracorporeal Circulation/adverse effects , Humans , Inflammation , Prospective Studies
3.
Ann Thorac Surg ; 105(4): 1168-1174, 2018 04.
Article in English | MEDLINE | ID: mdl-29233766

ABSTRACT

BACKGROUND: Surgical treatment of active prosthetic aortic valve endocarditis presents a challenge for cardiac surgeons because of tissue friability and destruction caused by infection. Sutureless prostheses, such as the Perceval S (LivaNova, Saluggia, Italy), have emerged as an option among the different surgical approaches for these complicated cases. METHODS: This study presents data from 9 patients who underwent aortic valve re-replacement with the Perceval S because of active prosthetic aortic valve endocarditis between January 2014 and August 2016. Hemodynamic performance (mean transprosthetic gradient and type of aortic regurgitation) was assessed intraoperatively after weaning from cardiopulmonary bypass, at discharge, and to 6 months postoperatively. RESULTS: After weaning from cardiopulmonary bypass, cases 1 and 3 through 6 had no or trivial aortic regurgitation, cases 7 and 8 presented with trivial to mild regurgitation, case 9 showed mild intraprosthetic regurgitation, and case 2 had mild periprosthetic regurgitation. Cases 4 and 7 died of septic shock and multiorgan failure in the perioperative period. In the remaining patients, severity of aortic regurgitation maintained practically invariable at discharge compared with intraoperative results. These 7 patients did well at 6-month follow-up, with good clinical and hemodynamic performance of the Perceval S prosthesis. The median of mean transprosthetic gradient was 11 mm Hg (interquartile range: 10 to 12 mm Hg). Only patient 2 showed mild periprosthetic regurgitation; patient 9 showed mild intraprosthetic insufficiency, and the remaining patients had no or trivial regurgitation. CONCLUSIONS: The sutureless Perceval S valve is a reasonable alternative for surgical treatment of prosthetic aortic valve endocarditis.


Subject(s)
Aortic Valve Insufficiency/surgery , Endocarditis/etiology , Endocarditis/surgery , Heart Valve Prosthesis , Prosthesis-Related Infections/surgery , Aged , Aged, 80 and over , Aortic Valve Insufficiency/etiology , Female , Humans , Male , Prosthesis Design , Prosthesis-Related Infections/etiology , Reoperation , Retrospective Studies , Sutures , Treatment Outcome
4.
Int J Cardiol ; 150(2): 173-6, 2011 Jul 15.
Article in English | MEDLINE | ID: mdl-20439120

ABSTRACT

OBJECTIVES: Assessment of the long term outcome of mechanical valve prosthesis at pulmonary position in a population of grown-up congenital heart disease patients from a tertiary referral center. METHODS: From 1977 to 2007, 22 consecutive patients underwent a total of 25 pulmonary valve replacements with mechanical prosthesis. The most frequent underlying cardiac condition was tetralogy of Fallot (n=16, 64%) and the mean age at the time of pulmonary valve replacement was 32 ± 11 years (range 14-50 years). RESULTS: The postoperative mortality rate was 4% (n=1) with no late deaths documented after a mean follow-up of 7.6 ± 7.6 years (range 0.29-24 years). No major bleeding episodes occurred. Three patients presented with valve thrombosis in the setting of long term anticoagulation withdrawal and required valve re-replacement. Two of these patients, both with poor right ventricular function and overt clinical signs of right heart failure at the time of valve re-replacement, experienced further episodes of thrombosis despite correct anticoagulation. All episodes resolved with thrombolysis. After addition of antiplatelet treatment in one case and anticoagulation self-control, in the other, no further thrombosis has been documented. CONCLUSIONS: Mechanical valve prosthesis may be an alternative to tissue valve prosthesis in patients with congenital heart disease requiring pulmonary valve replacement. Optimal anticoagulation is crucial and additional antiplatelet treatment should be considered. Our data also suggest that patients with severe right ventricular dysfunction and congestive heart failure might be at particular risk for valve thrombosis.


Subject(s)
Heart Valve Prosthesis Implantation/trends , Heart Valve Prosthesis/trends , Pulmonary Valve/pathology , Pulmonary Valve/surgery , Tetralogy of Fallot/diagnosis , Tetralogy of Fallot/surgery , Adolescent , Adult , Female , Follow-Up Studies , Heart Defects, Congenital/diagnosis , Heart Defects, Congenital/surgery , Heart Valve Prosthesis/adverse effects , Heart Valve Prosthesis Implantation/adverse effects , Humans , Male , Middle Aged , Time Factors , Treatment Outcome , Young Adult
5.
Interact Cardiovasc Thorac Surg ; 9(4): 748-9, 2009 Oct.
Article in English | MEDLINE | ID: mdl-19605468

ABSTRACT

Non-penetrating cardiac traumatisms can cause cardiac rupture, myocardial contusion or, rarely, commotio cordis. In cases of rupture of a cardiac cavity, acute and severe cardiac tamponade almost invariably occurs. This paper presents an exceptionally unusual case of non-penetrating cardiac trauma resulting in right atrium rupture contained by the pericardial cavity. A situation of exceptional hemodynamic balance was established with subacute, progressive cardiac tamponade that evolved during three months, presenting gradual right-heart failure instead of the expected acute and severe cardiac tamponade. The rupture of the atrium was successfully repaired.


Subject(s)
Cardiac Tamponade/etiology , Heart Injuries/complications , Hemodynamics , Pericardial Effusion/etiology , Aged , Cardiac Surgical Procedures , Cardiac Tamponade/diagnosis , Cardiac Tamponade/physiopathology , Cardiac Tamponade/surgery , Chronic Disease , Echocardiography, Transesophageal , Female , Heart Atria/injuries , Heart Atria/physiopathology , Heart Failure/etiology , Heart Failure/physiopathology , Heart Injuries/diagnosis , Heart Injuries/physiopathology , Heart Injuries/surgery , Humans , Pericardial Effusion/diagnosis , Pericardial Effusion/physiopathology , Pericardial Effusion/surgery , Time Factors , Tomography, X-Ray Computed , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...