Vet Rec ; 165(1): 22-5, 2009 Jul 04.
Article in English | MEDLINE | ID: mdl-19578191

ABSTRACT

Measurements of minute ventilation (VE) and expired oxygen and carbon dioxide fractions (FeO2 and FeCO2) were measured at rest and during exercise in seven warmblood horses performing two consecutive standardised incremental treadmill exercise tests at submaximal speed, using the portable K4b2 telemetric unit and the laboratory Quark metabolic cart in random order. Oxygen consumption (VO2) and carbon dioxide production (VCO2) were estimated using the Haldane equation. There were no significant differences between the measurements made with the two devices. However, VE was overestimated when the horses were cantering at 10 m/s in comparison with values available in the literature.


Subject(s)
Blood Gas Analysis/veterinary , Carbon Dioxide/analysis , Horses/metabolism , Physical Conditioning, Animal/physiology , Respiratory Function Tests/veterinary , Animals , Blood Gas Analysis/instrumentation , Blood Gas Analysis/methods , Breath Tests/instrumentation , Breath Tests/methods , Cross-Over Studies , Exercise Test , Oxygen/analysis , Oxygen Consumption/physiology , Pulmonary Gas Exchange , Pulmonary Ventilation , Random Allocation , Reproducibility of Results , Respiratory Function Tests/instrumentation , Respiratory Function Tests/standards , Sensitivity and Specificity , Telemetry/instrumentation , Telemetry/methods , Telemetry/veterinary