Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Publication year range
1.
Sci Rep ; 9(1): 16376, 2019 11 08.
Article in English | MEDLINE | ID: mdl-31704964

ABSTRACT

Optical fibers hold promise for accurate dosimetry in small field proton therapy due to their superior spatial resolution and the lack of significant Cerenkov contamination in proton beams. One known drawback for most scintillation detectors is signal quenching in areas of high linear energy transfer, as is the case in the Bragg peak region of a proton beam. In this study, we investigated the potential of innovative optical fiber bulk materials using the sol-gel technique for dosimetry in proton therapy. This type of glass is made of amorphous silica (SiO[Formula: see text]) and is doped with Gd[Formula: see text] ions and possesses very interesting light emission properties with a luminescence band around 314 nm when exposed to protons. The fibers were manufactured at the University of Lille and tested at the TRIUMF Proton Therapy facility with 8.2-62.9 MeV protons and 2-6 nA of extracted beam current. Dose-rate dependence and quenching were measured and compared to other silica-based fibers also made by sol-gel techniques and doped with Ce[Formula: see text] and Cu[Formula: see text]. The three fibers present strong luminescence in the UV (Gd) or visible (Cu,Ce) under irradiation, with the emission intensities related directly to the proton flux. In addition, the 0.5 mm diameter Gd[Formula: see text]-doped fiber shows superior resolution of the Bragg peak, indicating significantly reduced quenching in comparison to the Ce[Formula: see text] and Cu[Formula: see text] fibers with a Birks' constant, k[Formula: see text], of (0.0162 [Formula: see text] 0.0003) cm/MeV in comparison to (0.0333 [Formula: see text] 0.0006) cm/MeV and (0.0352 [Formula: see text] 0.0003) cm/MeV, respectively. To our knowledge, this is the first report of such an interesting k[Formula: see text] for a silica-based optical fiber material, showing clearly that this fiber presents lower quenching than common plastic scintillators. This result demonstrates the high potential of this inorganic fiber material for proton therapy dosimetry.


Subject(s)
Gadolinium , Optical Fibers , Proton Therapy , Radiometry/instrumentation , Humans , Linear Energy Transfer , Luminescence , Phantoms, Imaging , Protons , Radiometry/methods , Silicon Dioxide
2.
Appl Opt ; 58(22): 6165-6172, 2019 Aug 01.
Article in English | MEDLINE | ID: mdl-31503942

ABSTRACT

We studied the impact of ionizing radiation at high dose levels (megagray, MGy) on the photometric budget of a radiation-resistant complementary metal oxide semi-conductor (CMOS)-based camera. This is achieved by measuring the radiation-induced degradation of each subpart, namely its illumination system, its optical system, and its CMOS image sensor. The acquired experimental results allow performing a rather realistic simulation of the radiation effects at the system level. Thanks to appropriate mitigation techniques, limited image darkening and color change are obtained at MGy dose levels. The presented results confirm the feasibility of a CMOS-based camera able to resist to MGy dose level of ionizing radiations with an acceptable degradation of the image quality, opening the way to its implementation in the most challenging harsh environments.

3.
Opt Lett ; 40(20): 4571-4, 2015 Oct 15.
Article in English | MEDLINE | ID: mdl-26469566

ABSTRACT

We investigate the radiation effects on germanosilicate optical fiber acting as the sensing element of optical frequency domain reflectometry devices. Thanks to a new setup permitting to control temperature during irradiation, we evaluate the changes induced by 10 keV x rays on their Rayleigh response up to 1 MGy in a temperature range from -40°C up to 75°C. Irradiation at fixed temperature points out that its measure is reliable during both irradiation and the recovery process. Mixed temperature and radiation measurements show that changing irradiation temperature leads to an error in distributed measurements that depends on the calibration procedure. These results demonstrate that Rayleigh-based optical fiber sensors are very promising for integration in harsh environments.

4.
Opt Lett ; 39(18): 5313-6, 2014 Sep 15.
Article in English | MEDLINE | ID: mdl-26466259

ABSTRACT

We report a method for fabricating fiber Bragg gratings (FBG) resistant to very severe environments mixing high radiation doses (up to 3 MGy) and high temperatures (up to 230°C). Such FBGs have been written in two types of radiation resistant optical fibers (pure-silica and fluorine-doped cores) by exposures to a 800 nm femtosecond IR laser at power exceeding 500 mW and then subjected to a thermal annealing treatment of 15 min at 750°C. Under radiation, our study reveals that the radiation induced Bragg wavelength shift (BWS) at a 3 MGy dose is strongly reduced compared to responses of FBGs written with nonoptimized conditions. The BWS remains lower than 10 pm for temperatures of irradiation ranging from 25°C to 230°C without noticeable decrease of the FBG peak amplitude. For an applicative point of view, this radiation induced BWS corresponds to an additional error on the temperature measurements lower than 1.5°C, opening the way to the development of radiation-tolerant multi-point temperature sensors for nuclear industry.

5.
Opt Express ; 20(18): 20028-42, 2012 Aug 27.
Article in English | MEDLINE | ID: mdl-23037056

ABSTRACT

CMOS image sensors (CIS) are promising candidates as part of optical imagers for the plasma diagnostics devoted to the study of fusion by inertial confinement. However, the harsh radiative environment of Megajoule Class Lasers threatens the performances of these optical sensors. In this paper, the vulnerability of CIS to the transient and mixed pulsed radiation environment associated with such facilities is investigated during an experiment at the OMEGA facility at the Laboratory for Laser Energetics (LLE), Rochester, NY, USA. The transient and permanent effects of the 14 MeV neutron pulse on CIS are presented. The behavior of the tested CIS shows that active pixel sensors (APS) exhibit a better hardness to this harsh environment than a CCD. A first order extrapolation of the reported results to the higher level of radiation expected for Megajoule Class Laser facilities (Laser Megajoule in France or National Ignition Facility in the USA) shows that temporarily saturated pixels due to transient neutron-induced single event effects will be the major issue for the development of radiation-tolerant plasma diagnostic instruments whereas the permanent degradation of the CIS related to displacement damage or total ionizing dose effects could be reduced by applying well known mitigation techniques.


Subject(s)
Image Enhancement/instrumentation , Image Interpretation, Computer-Assisted/instrumentation , Lasers , Semiconductors , Transducers , Equipment Design , Equipment Failure , Equipment Failure Analysis , Reproducibility of Results , Sensitivity and Specificity
6.
Bioorg Med Chem Lett ; 14(17): 4439-43, 2004 Sep 06.
Article in English | MEDLINE | ID: mdl-15357968

ABSTRACT

Synthesis of a new family of quinolylhydrazone derivatives and evaluation of their activity against a chloroquine-resistant strain of Plasmodium falciparum are described. The best compound displayed an activity 6-fold higher than chloroquine. None of the active compounds were found to inhibit beta-hematin formation in vitro in the same range as chloroquine and five among them displayed lower calculated vacuolar accumulation ratios, suggesting the implication of a different mechanism of action.


Subject(s)
Antimalarials/chemical synthesis , Glyoxylates/chemical synthesis , Hydrazones/chemical synthesis , Animals , Antimalarials/pharmacology , Glyoxylates/pharmacology , Hydrazones/pharmacology , Plasmodium falciparum/drug effects , Plasmodium falciparum/growth & development
SELECTION OF CITATIONS
SEARCH DETAIL
...