J Arthroplasty ; 36(11): 3703-3708.e2, 2021 11.
Article in English | MEDLINE | ID: mdl-34253441

ABSTRACT

BACKGROUND: In 2016, the CPT stem replaced the Exeter stem as the main cemented stem at our institution. We assessed the prevalence of revision for periprosthetic femoral fracture (PFF) in patients operated on with either CPT or Exeter stem and compared the risk for revision between these stems. METHODS: Primary total hip arthroplasties either performed in 2012-2015 with Exeter stem (n = 1443) or in 2017-2018 with CPT stem (n = 1322) were included. The prevalence of revision for PFF was compared. The Kaplan-Meier estimated survivorships were calculated for the 2 stem designs. The risk for revision was analyzed using the Cox proportional hazard regression model. RESULTS: At 2 years, PFF was the most common reason for revision in the study population (1.3% prevalence, comprising 35% of all revisions). Moreover, 1.6% (95% confidence interval [CI] 1.0-2.4) of the CPT and 1.0% (95% CI 0.6-1.6) of the Exeter stems had been revised due to PFF. The 3-year Kaplan-Meier probability estimates for all-cause revision were 4.8% for the CPT (95% CI 3.6-6.0) and 3.3% for the Exeter stem (95% CI 2.3-4.3). The hazard ratio for revision due to any reason was 1.1 (95% CI 0.3-3.8) during the first 2 weeks, and 1.8 (95% CI 1.2-2.7, P = .006) from 2 weeks onwards for the CPT compared with the Exeter stem. CONCLUSION: The considerable number of PFF revisions with taper-slip stems, especially with CPT stems, is a matter of concern. Alternative cemented stems should be considered in patients at high risk for PFF.


Subject(s)
Arthroplasty, Replacement, Hip , Femoral Fractures , Hip Prosthesis , Periprosthetic Fractures , Arthroplasty, Replacement, Hip/adverse effects , Femoral Fractures/epidemiology , Femoral Fractures/etiology , Femoral Fractures/surgery , Hip Prosthesis/adverse effects , Hospitals, High-Volume , Humans , Periprosthetic Fractures/epidemiology , Periprosthetic Fractures/etiology , Periprosthetic Fractures/surgery , Prosthesis Design , Prosthesis Failure , Reoperation
2.
Acta Orthop ; 91(3): 279-285, 2020 06.
Article in English | MEDLINE | ID: mdl-32233815

ABSTRACT

Background and purpose - The introduction of new total hip replacements (THRs) is known to be associated with an increased risk for complications. On completion of a competitive procurement process, a new uncemented cup system was introduced into general use at our institution in 2016. We launched this study after the introduction to assess (1) the incidence of early dislocations of the old (Pinnacle) and the new (Continuum) cup systems, and (2) whether the cup design would affect the risk for dislocation.Patients and methods - We assessed the incidence of dislocations after 1,381 primary THRs performed at our institution during 2016. Also, the effect of the cup system (Pinnacle, Continuum with neutral liner, Continuum with elevated rim liner) on dislocation rates was analyzed using a multivariable regression model.Results - 47 (3.4%) early dislocations were identified. The incidence of dislocations was 1.3% for the Pinnacle, 5.1% for the Continuum with neutral liner, and 1.2% for the Continuum with elevated rim liner. The Continuum with neutral liner was found to have an increased risk for dislocations compared with the Pinnacle (aOR 5, 95% CI 1.4-17). However, when an elevated rim liner was used with the Continuum, the risk for dislocation between the Continuum and the Pinnacle was similar.Interpretation - Our results emphasize the need for both careful consideration before the introduction of new implants and the systematic monitoring of early outcomes thereafter. The elevated rim liner should be preferred for use with the Continuum cup because of the poor coverage of the neutral liner that may result in dislocations.


Subject(s)
Arthroplasty, Replacement, Hip/adverse effects , Hip Prosthesis/adverse effects , Prosthesis Failure/etiology , Aged , Cohort Studies , Female , Follow-Up Studies , Humans , Male , Middle Aged , Prosthesis Failure/adverse effects , Risk Factors