Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Oral Dis ; 2024 Apr 24.
Article in English | MEDLINE | ID: mdl-38654640

ABSTRACT

OBJECTIVE: To carry out a systematic review and meta-analysis of randomized controlled clinical trials (RCTs) and controlled clinical trials (CCTs) comparing scaling and root planing (SRP) or placebo with subgingival application of xanthan-based CHX (chlorhexidine) gel as adjunct to SRP. MATERIALS AND METHODS: The literature search was carried out in PubMed/MEDLINE, EMBASE, and SCOPUS; primary outcomes were probing pocket depth (PPD) reduction and gain in clinical attachment level (CAL). RESULTS: Overall, 15 studies were included. Three studies were judged to be at moderate risk of bias while the remaining 12 were rated at high risk of bias. A significant improvement in PPD reduction (standardized mean difference, SMD, 0.87, 95% CI, 0.41-1.34) and CAL gain (SMD = 0.84, 95% CI, 0.36-1.33) emerged for the SRP + CXH gel compared to the SRP alone group, in the presence of significant high heterogeneity among the studies. CONCLUSIONS: Our systematic review and meta-analysis showed that xanthan-based chlorhexidine gel as adjunct to non-surgical periodontal therapy gives benefit in terms of PPD reduction and CAL gain as compared to non-surgical periodontal therapy only. Since there was high heterogeneity among studies and the quality of the evidence is low, further studies characterized by a better methodology, adequate sample size and longer follow-up are warranted in the next future. REGISTRATION: The protocol of this scoping review was registered in the International Prospective Register of Systematic Reviews (https://www.crd.york.ac.uk/PROSPERO) with ID: CRD42023391589.

2.
J Clin Med ; 12(11)2023 Jun 04.
Article in English | MEDLINE | ID: mdl-37298041

ABSTRACT

Computer-aided design and computer-aided manufacturing customized abutments are increasingly used in everyday clinical practice. Nevertheless, solid scientific evidence is currently lacking regarding their potential advantages in terms of soft tissue stability. The main aim of this systematic review and meta-analysis was to compare the soft tissue outcomes of prefabricated versus customized (CAD/CAM) abutments. The present review was registered with PROSPERO (CRD42020161875) and the protocol was developed according to the PRISMA statement. An electronic search was performed on three databases (PubMed, Embase and Cochrane Central) up to May 2023. Data extraction was followed by qualitative and quantitative analysis of the included studies. Three randomized controlled clinical trials and three controlled clinical trials (number of patients = 230; number of dental implants = 230) with a follow-up of between 12 and 36 months were included. No significant differences were observed between prefabricated versus customized (CAD/CAM) abutments regarding midfacial mucosal recession, interproximal papillae and pink aesthetic score (PES) after 12 months. Conclusion: The potential benefits of CAD/CAM abutments on soft tissues should be better clarified in future investigations. The usage of customized CAD/CAM abutments in everyday clinical practice should be based on a careful case-by-case evaluation (CRD42020161875).

3.
J Clin Med ; 11(21)2022 Oct 23.
Article in English | MEDLINE | ID: mdl-36362471

ABSTRACT

BACKGROUND: The aim of the present retrospective study was to assess peri-implant soft tissue health for implants restored with different prosthetic emergence profile angles. METHODS: Patients were treated with implants supporting fixed dentures and were followed for 3 years. Buccal emergence angle (EA) measured at 3 years of follow-up visits (t1) were calculated for two different groups: Group 1 (153 implants) for restorations with angle between implant axis and prosthetic emergence angle from ≥30°, and Group 2 (67 implants) for those with angle ≤30°, respectively. Image J software was used for the measurements. Moreover, peri-implant soft tissue parameters such as pocket probing depth (PPD), plaque index (PI) and gingival index (GI) were assessed, respectively. RESULTS: A total of 57 patients were included in the analysis and a total of 220 implants were examined. Mean (±SD) EA in Groups 1 and 2 was 46.4 ± 12.2 and 24.5 ± 4.7 degrees, respectively. After 3 years of follow-up, a PPD difference of 0.062 mm (CI95% -0.041 mm; 0.164 mm) was calculated between the two groups and was not statistically significant (p = 0.238). Similar results were found for PI (OR = 0.78, CI95% 0.31; 1.98, p = 0.599). Furthermore, GI scores of 2 and 3 were found for nine implants (5.9%) in Group 1, and for five implants in Group 2 (7.5%). A non-significant difference (p = 0.76) was found. CONCLUSIONS: Peri-implant soft-tissue health does not seem to be influenced by EA itself, when a proper emergence profile is provided for implant-supported reconstructions in anterior areas.

4.
J Clin Med ; 11(7)2022 Apr 04.
Article in English | MEDLINE | ID: mdl-35407622

ABSTRACT

The aim of the present retrospective study was to assess marginal bone changes around implants restored with different prosthetic emergence profile angles. Patients were treated with implants supporting fixed dentures and were followed for 3 years. Marginal bone levels (MBL) measured at the prosthesis installation (t0) and at the 3-year follow-up visit (t1) were considered. The MBL change from t0 to t1 was investigated. Two groups were considered: Group 1 for restorations with an angle between implant axis and prosthetic emergence profile >30°, and Group 2 for those with an angle ≤30°, respectively. Moreover, peri-implant soft tissue parameters, such as the modified bleeding index (MBI) and plaque index (PI) were assessed. Seventy-four patients were included in the analysis and a total of 312 implants were examined. The mean EA in groups 1 and 2 was 45 ± 4 and 22 ± 7 degrees, respectively. The mean marginal bone level change (MBL change) of 0.06 ± 0.09 mm and 0.06 ± 0.10 mm were, respectively, in groups 1 and 2. The difference in the MBL change between the two groups was not statistically significant (p = 0.969). The MBL change does not seem to be influenced by the emergence angle for implants with a stable internal conical connection and platform-switching of the abutment diameter.

5.
Materials (Basel) ; 13(14)2020 Jul 13.
Article in English | MEDLINE | ID: mdl-32668745

ABSTRACT

BACKGROUND: There is limited information on the effect of the connection between subcrestally placed implants and abutments on marginal bone levels. The aim of the present retrospective study was to evaluate marginal bone levels after definitive prosthesis delivery around implants with an internal 5° conical connection placed in a subcrestal position. MATERIALS AND METHODS: Patients treated with fixed prostheses supported by implants placed at a subcrestal level between 2012 and 2018 were recalled for a follow-up examination. All implants had 5° internal conical connection with platform switching. Radiographic marginal bone level (MBL) was measured. MBL change between prosthetic delivery (t0) and follow-up examination (t1) was calculated. A multiple regression model was performed to identify the most significant predictors on MBL change. RESULTS: Ninety-three patients and 410 implants, with a mean follow-up of 2.72 ± 1.31 years, were examined. Mean MBL was -1.09 ± 0.65 mm and -1.00 ± 0.37 mm at t0 and t1, respectively, with a mean bone remodeling of 0.09 ± 0.68 mm. An implant's vertical position in relation to the bone crest, the year of follow up and the presence of type-2 controlled diabetes were demonstrated to be influencing factors for MBL modifications. CONCLUSIONS: Subcrestally placed implants with platform switching and internal conical connection maintained stable bone levels over a mean follow-up of more than 2 years. How a tight internal conical connection between abutment and implant may contribute to this clinical evidence should be more deeply investigated. MBL variations seem to be mostly influenced by an implant's vertical position and presence of type-2 controlled diabetes.

SELECTION OF CITATIONS
SEARCH DETAIL
...