1.
J AOAC Int ; 89(3): 772-81, 2006.
Article in English | MEDLINE | ID: mdl-16792075

ABSTRACT

A collaborative study was conducted to validate an analytical method for quantification of the 15 polycyclic aromatic hydrocarbons (PAHs) regarded in 2002 as a health concern by the former Scientific Committee on Food of the European Commission (SCF) in primary smoke condensates. The method is based on gas chromatography/mass spectrometry of a cyclohexane extract with solid-phase cleanup through silica gel. The analytes were detected in the selected-ion monitoring mode and quantified by using 3 isotopically labeled internal standard compounds. Seventeen laboratories participated in the collaborative validation study, of which 12 reported valid results. The data were subjected to Cochran, single Grubbs, and double Grubbs tests for statistical outliers. A maximum of 2 outliers was eliminated before further statistical evaluation of the method performance characteristics. Depending on the analyte, the results showed relative standard deviations for repeatability between 4.2 and 30% and for reproducibility from 9.9 to 60%. The recoveries varied between about 50 and 85%, except those for cyclopenta[cd]pyrene, dibenzo[a,l]pyrene, and dibenzo[a,h]pyrene. Nevertheless, because Commission Directive 2005/10/EC allows for a recovery range of 50-120% for (BaP) benzo[a]pyrene in various foods, it can be concluded that the method performs appropriately within the analytical range between 5 and 25 microg/kg of primary smoke condensate. For BaP the validated analytical range covered 5-20 microg/kg, and for benzo[a]anthracene (BaA) 10-25 microg/kg. The method is suitable for monitoring BaP and BaA at their respective maximum permitted levels of 10 and 20 microg/kg. Three analytes, benzo[b]-, benzo[j]-, and benzo[k]-fluoranthene could not be separated by all of the participants and were therefore treated as the sum. Nevertheless, with this method the pattern of the respective concentrations of these 15 PAHs can be monitored in primary smoke condensate as suggested by the SCF.


Subject(s)
Chemistry Techniques, Analytical/methods , Gas Chromatography-Mass Spectrometry/methods , Polycyclic Aromatic Hydrocarbons/analysis , Cyclohexanes/analysis , Humans , Models, Chemical , Polycyclic Compounds/analysis , Reproducibility of Results , Silicon Dioxide/analysis , Smoke
2.
J Chromatogr A ; 1103(2): 307-13, 2006 Jan 27.
Article in English | MEDLINE | ID: mdl-16343513

ABSTRACT

An existing method was adapted to the purpose and validated in-house according to the IUPAC harmonised guideline for the determination of 15 EU priority polycyclic aromatic hydrocarbons (PAHs) in primary smoke condensates (PSCs) that are used to produce smoke flavourings for human consumption. Limits of detection (LOD) varied between 0.1 and 1.3 microg/kg, limits of quantitation (LOQ) between 0.5 and 4 microg/kg for the various PAHs in PSCs. The coefficient of variance of the repeatability was between 0.7% (benzo[a]pyrene) and 30% (dibenzo[a,h]pyrene) relative standard deviation, depending on the analyte. The recoveries varied between 100 and 102% (dibenzo[a,l]pyrene) and 69-83% (dibenzo[a,h]pyrene) over the analytical range of 5-35 microg/kg.


Subject(s)
Flavoring Agents/chemistry , Gas Chromatography-Mass Spectrometry/methods , Polycyclic Aromatic Hydrocarbons/analysis , Smoke/analysis , Benz(a)Anthracenes/analysis , Benzo(a)pyrene/analysis , Reproducibility of Results
3.
J Sep Sci ; 28(9-10): 871-82, 2005 Jun.
Article in English | MEDLINE | ID: mdl-16013813

ABSTRACT

Smoke flavourings are produced on a large scale and have been applied to a variety of food products for more than 30 years. The use of them has many advantages compared to traditional smoking techniques. Among others, the amount of (known) toxic compounds deriving from combustion processes can be more easily controlled in smoke flavourings. In order to ensure safe products, a new European Regulation requests data on the composition and lays down, in particular, the maximum permitted concentrations for selected polycyclic aromatic hydrocarbons (PAHs). This review compiles results published on the chemical composition of liquid smoke flavouring primary products, partly in relation to production process parameters, and the analytical methods involved. The methods cover chromatographic techniques for analysis of specific compounds including extraction methods and clean-up procedures. Analysis of sensorial and bulk parameters such as acidity and total phenolic compounds are described as well as they are used as standard methods for analysis of liquid smoke flavourings. A special section is devoted to discussing the analysis of PAHs.


Subject(s)
Flavoring Agents/analysis , Smoke , Chromatography, Gas/methods , Food Analysis/legislation & jurisprudence , Polycyclic Compounds/analysis