Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
J AOAC Int ; 105(2): 521-548, 2022 Mar 15.
Article in English | MEDLINE | ID: mdl-34613392

ABSTRACT

BACKGROUND: The Thermo Scientific SureTect™ Escherichia coli O157:H7 and STEC Screening PCR Assay and SureTect Escherichia coli STEC Identification PCR Assay are real-time PCR kits for the rapid detection of E. coli O157:H7 and non-E. coli O157 Shiga toxin-producing E. coli (STEC) serotypes (O26, O45, O103, O111, O121, O145) from fresh raw spinach, fresh baby leaves, fresh cut tomatoes, frozen raw beef, raw beef trim, and beef carcass sponges. OBJECTIVE: Both assays were evaluated for AOAC®Performance Tested MethodsSM certification. METHODS: Detection and confirmation inclusivity/exclusivity, matrix, product consistency and stability, and robustness studies were conducted. In the matrix studies, the candidate method was validated against United States and international reference methods for STEC serotypes. RESULTS: Matrix studies showed no statistically significant differences between the candidate and reference method results when analyzed by probability of detection. For each inclusivity/exclusivity study, all inclusivity strains and no exclusivity strains were detected by either kit. Robustness testing demonstrated that the identification assay performed reliably despite method deviations; however, although not statistically significant, the screening assay performance was impacted. Product consistency and stability testing demonstrated no statistically significant differences between kit lots and storage time points. CONCLUSION: The data presented show that both assays constitute a rapid and reliable workflow for the detection and confirmation of E. coli O157:H7 and stipulated non-E. coli O157:H7 STEC serotypes from the tested matrixes. HIGHLIGHTS: Results are obtained in 80 min post-enrichment with both assays run simultaneously, allowing for the detection and confirmation of STEC within a single workflow.


Subject(s)
Escherichia coli O157 , Shiga-Toxigenic Escherichia coli , Solanum lycopersicum , Animals , Cattle , Escherichia coli O157/genetics , Food Microbiology , Plant Leaves , Real-Time Polymerase Chain Reaction , Serogroup , Shiga-Toxigenic Escherichia coli/genetics , Spinacia oleracea , United States
2.
J AOAC Int ; 105(2): 506-520, 2022 Mar 15.
Article in English | MEDLINE | ID: mdl-34613414

ABSTRACT

BACKGROUND: The Thermo Scientific SureTect™ Campylobacter jejuni, C. coli, and C. lari PCR Kit is a real-time PCR assay for the detection and differentiation of C. jejuni, C. coli, and C. lari from raw poultry, ready-to-cook poultry products, and environmental samples. OBJECTIVE: The Thermo Scientific SureTect Campylobacter jejuni, C. coli, and C. lari PCR Kit was evaluated for AOAC®Performance Tested MethodsSM certification. METHODS: Inclusivity/exclusivity, matrix studies, product consistency and stability, and robustness testing were conducted to assess the method's performance. In the matrix studies, the method was validated against United States and international reference methods for Campylobacter detection. RESULTS: There were no statistically significant differences found in the matrix studies between the candidate and reference methods when analyzed by probability of detection. All 52 inclusivity strains and none of the 51 exclusivity strains tested were detected by the assay. Robustness testing demonstrated that the assay gave reliable performance with specific method deviations outside of the recommended parameters, and the real-time stability testing demonstrated that there were no statistically significant differences between kit lots, validating the stated shelf life of the kit. CONCLUSION: The data presented support the product claims that the Thermo Scientific SureTect Campylobacter jejuni, C. coli, and C. lari PCR assay is suitable for the detection and differentiation of C. jejuni, C. coli, and C. lari from raw poultry, ready-to-cook poultry products, and environmental samples. HIGHLIGHTS: Presumptive results can be obtained in as little as 23 h. Microaerophilic incubators are not required for enrichment.


Subject(s)
Campylobacter coli , Campylobacter jejuni , Campylobacter , Animals , Campylobacter/genetics , Campylobacter coli/genetics , Campylobacter jejuni/genetics , Poultry , Poultry Products , Real-Time Polymerase Chain Reaction/methods
3.
J AOAC Int ; 99(3): 676-85, 2016 May.
Article in English | MEDLINE | ID: mdl-27297838

ABSTRACT

In 2013, the Thermo Scientific™ SureTect™ Listeria monocytogenes Real-Time PCR Assay was certified by the AOAC Research Institute (RI) Performance Tested Methods(SM) program as a rapid method for the detection of L. monocytogenes from a wide range of food matrixes and surface samples. This report details the method modification studies undertaken to extend the analysis of this PCR assay to the Applied Biosystems™ 7500 Fast PCR Instrument and Applied Biosystems RapidFinder™ Express 2.0 software allowing the use of the SureTect assay on a 96 well format PCR cycler in addition to the current workflow, which uses the 24 well Thermo Scientific PikoReal™ PCR Instrument and Thermo Scientific SureTect software. Because this study was deemed by AOAC-RI to be a level 2 method modification study, a representative range of food matrixes covering raw ground turkey, 2% fat pasteurized milk, and bagged lettuce as well as stainless steel surface samples were analyzed with the Applied Biosystems 7500 Fast PCR Instrument and RapidFinder Express 2.0 software. All testing was conducted in comparison to the reference method detailed in International Organization for Standardization (ISO) 6579:2002. No significant difference by probability of detection statistical analysis was found between the SureTect Listeria monocytogenes PCR Assay or the ISO reference method methods for any of the matrixes analyzed during the study.


Subject(s)
Bacteriological Techniques/instrumentation , Listeria monocytogenes/genetics , Listeria monocytogenes/isolation & purification , Real-Time Polymerase Chain Reaction
4.
J AOAC Int ; 99(2): 407-16, 2016.
Article in English | MEDLINE | ID: mdl-26923177

ABSTRACT

The Thermo Scientific™ SureTect™ Listeria species Real-Time PCR Assay was certified during 2013 by the AOAC Research Institute (RI) Performance Tested Methods(SM) program as a rapid method for the detection of Listeria species from a wide range of food matrixes and surface samples. A method modification study was conducted in 2015 to extend the matrix claims of the product to a wider range of food matrixes. This report details the method modification study undertaken to extend the use of this PCR kit to the Applied Biosystems™ 7500 Fast PCR Instrument and Applied Biosystems RapidFinder™ Express 2.0 software allowing use of the assay on a 96-well format PCR cycler in addition to the current workflow, using the 24-well Thermo Scientific PikoReal™ PCR Instrument and Thermo Scientific SureTect software. The method modification study presented in this report was assessed by the AOAC-RI as being a level 2 method modification study, necessitating a method developer study on a representative range of food matrixes covering raw ground turkey, 2% fat pasteurized milk, and bagged lettuce as well as stainless steel surface samples. All testing was conducted in comparison to the reference method detailed in International Organization for Standardization (ISO) 6579:2002. No significant difference by probability of detection statistical analysis was found between the SureTect Listeria species PCR Assay or the ISO reference method methods for any of the three food matrixes and the surface samples analyzed during the study.


Subject(s)
Food Analysis , Food Microbiology , Listeria/genetics , Listeria/isolation & purification , Real-Time Polymerase Chain Reaction , Humans , Listeria/classification , Real-Time Polymerase Chain Reaction/standards , Reference Standards
SELECTION OF CITATIONS
SEARCH DETAIL
...