Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
Add more filters










Publication year range
1.
Sci Justice ; 62(4): 433-447, 2022 07.
Article in English | MEDLINE | ID: mdl-35931449

ABSTRACT

The forensic scenario, on which the round robin study was based, simulated a suspected intentional manipulation of a real estate rental agreement consisting of a total of three pages. The aims of this study were to (i) establish the amount and reliability of information extractable from a single type of evidence and to (ii) provide suggestions on the most suitable combination of compatible techniques for a multi-modal imaging approach to forgery detection. To address these aims, seventeen laboratories from sixteen countries were invited to answer the following tasks questions: (i) which printing technique was used? (ii) were the three pages printed with the same printer? (iii) were the three pages made from the same paper? (iv) were the three pages originally stapled? (v) were the headings and signatures written with the same ink? and (vi) were headings and signatures of the same age on all pages? The methods used were classified into the following categories: Optical spectroscopy, including multispectral imaging, smartphone mapping, UV-luminescence and LIBS; Infrared spectroscopy, including Raman and FTIR (micro-)spectroscopy; X-ray spectroscopy, including SEM-EDX, PIXE and XPS; Mass spectrometry, including ICPMS, SIMS, MALDI and LDIMS; Electrostatic imaging, as well as non-imaging methods, such as non-multimodal visual inspection, (micro-)spectroscopy, physical testing and thin layer chromatography. The performance of the techniques was evaluated as the proportion of discriminated sample pairs to all possible sample pairs. For the undiscriminated sample pairs, a distinction was made between undecidability and false positive claims. It was found that none of the methods used were able to solve all tasks completely and/or correctly and that certain methods were a priori judged unsuitable by the laboratories for some tasks. Correct results were generally achieved for the discrimination of printer toners, whereas incorrect results in the discrimination of inks. For the discrimination of paper, solid state analytical methods proved to be superior to mass spectrometric methods. None of the participating laboratories deemed addressing ink age feasible. It was concluded that correct forensic statements can only be achieved by the complementary application of different methods and that the classical approach of round robin studies to send standardised subsamples to the participants is not feasible for a true multimodal approach if the techniques are not available at one location.


Subject(s)
Forensic Medicine , Ink , Forensic Medicine/methods , Humans , Laboratories , Mass Spectrometry , Reproducibility of Results
2.
Micromachines (Basel) ; 12(2)2021 Jan 20.
Article in English | MEDLINE | ID: mdl-33498471

ABSTRACT

In this work, the results on the detection and identification of Bacillus thuringiensis (Bt) cells by using surface-enhanced Raman spectroscopy (SERS) are presented. Bt has been chosen as a harmless surrogate of the pathogen Bacillus anthracis (Ba) responsible for the deadly Anthrax disease, because of their genetic similarities. Drops of 200 µL of Bt suspensions, with concentrations 102 CFU/mL, 104 CFU/mL, 106 CFU/mL, were deposited on a SERS chip and sampled after water evaporation. To minimize the contribution to the SERS data given by naturally occurring interferents present in a real scenario, the SERS chip was functionalized with specific phage receptors BtCS33, that bind Bt (or Ba) cells to the SERS surface and allow to rinse the chip removing unwanted contaminants. Different chemometric approaches were applied to the SERS data to classify spectra from Bt-contaminated and uncontaminated areas of the chip: Principal Component Regression (PCR), Partial Least Squares Regression (PLSR) and Data Driven Soft Independent Modeling of Class Analogy (DD-SIMCA). The first two was tested and trained by using data from both contaminated and un-contaminated chips, the last was trained by using data from un-contaminated chips only and tested with all the available data. All of them were able to correctly classify the SERS spectra with great accuracy, the last being suitable for an automated recognition procedure.

3.
Sensors (Basel) ; 20(13)2020 Jul 04.
Article in English | MEDLINE | ID: mdl-32635434

ABSTRACT

Laser-induced breakdown spectroscopy (LIBS) was tested for all of the relevant issues in forensic examinations of commercial inks, including classification of pen inks on one paper type and on different paper types, determination of the deposition order of layered inks, and analysis of signatures and toners on one questioned document. The scope of this work was to determine the potential of a single LIBS setup that is compatible with portable instruments for different types of ink analysis, rather than building a very large database for inks and papers. We identified up to seven metals characteristic for the examined inks, which allowed to fully discriminate all eight black inks on one type of printing paper. When the inks were tested on ten different papers, the correct classification rates for some of them were reduced for reasons thoroughly studied and explained. The replicated tests on three crossing points, each one involving a pair of blue or black inks, were successful in five cases out of six. In the test simulating documents of forensic interest (questioned documents), LIBS was able to correctly identify the differences in three inks used for signatures on one of the three pages and the use of different printing inks on each page of the document.

4.
Sensors (Basel) ; 20(2)2020 Jan 11.
Article in English | MEDLINE | ID: mdl-31940781

ABSTRACT

An innovative hyperspectral LIDAR instrument has been developed for applications in marine environment monitoring research activities, remotely detecting the fluorescence spectra produced in the spectral interval between 400 nm and 720 nm. The detection system is composed by a custom made photomultiplier charge integrating and measuring (CIM) unit, which makes automatic background signal subtraction, and a liquid crystal tunable filter (LCTF). The new instrument therefore has hyperspectral resolution and allows automatic background subtraction; it is compact and automated by custom software that permit to adapt the instrument properties depending on the environmental conditions. Laboratory tests to characterize the instrument performance have been carried out, concluding that this sensor can be employed in remote sites for Chl-a detection.

5.
Sensors (Basel) ; 19(19)2019 Oct 01.
Article in English | MEDLINE | ID: mdl-31581543

ABSTRACT

Here, we describe an innovative Integrated Laser Sensor (ILS) that combines four spectroscopic techniques and two vision systems into a unique, transportable device. The instrument performs Raman and Laser-Induced Fluorescence (LIF) spectroscopy excited at 355 nm and Laser-Induced Breakdown Spectroscopy (LIBS) excited at 1064 nm, and it also detects Laser Scattering (LS) from the target under illumination at 650 nm. The combination of these techniques supplies information about: material change from one scanning point to another, the presence of surface contaminants, and the molecular and elemental composition of top target layers. Switching between the spectroscopic techniques and the laser wavelengths is fully automatic. The instrument is equipped with an autofocus, and it performs scanning with a chosen grid density over an interactively-selected target area. Alternative to the spectroscopic measurements, it is possible to switch the instrument to a high magnification target viewing. The working distances tested until now are between 8.5 and 30 m. The instrument is self-powered and remotely controlled via wireless communication. The ILS has been fully developed at ENEA for security applications, and it was successfully tested in two outdoor campaigns where an automatic recognition of areas containing explosives in traces had been implemented. The strategies for the identification of nitro-compounds placed on various substrates as fingerprints and the results obtained at a working distance of 10 m are discussed in the following.

6.
Appl Spectrosc ; 71(4): 670-677, 2017 Apr.
Article in English | MEDLINE | ID: mdl-28106472

ABSTRACT

We studied changes in laser-induced breakdown spectroscopy (LIBS) signal intensity with the thickness of a liquid layer placed on a solid substrate, where an easily evaporating methanol sample was used. For a certain optimal liquid film thickness we obtained a manifold increase of the LIBS signal from methanol. Progressive liquid film thinning leads to a reduction and a successive disappearance of laser-induced splashes; the latter condition drastically reduces the sample consumption and allows measurements to be repeated many times on a single liquid droplet. In following, we developed two methods for actively controlled deformation, i.e., thinning of a liquid droplet (volume ∼10 µl) prior to its sampling by LIBS. Control of the droplet's height was achieved on a Si-SiO2 wafer substrate by electro-wetting in the case of water solutions or by target rotation in the case of viscous liquids. The chosen substrate also has the advantages of low cost, easy manipulation, and very high purity, thus minimizing interference with analytes. Through the droplet deformation, in a single-pulse excitation at moderate laser energy (70 mJ), we clearly detected Fe and Mn in peanut oil, which represent trace elements in edible oils (∼ 1 part per billion), according to results published in the literature.

7.
Sensors (Basel) ; 16(1)2015 Dec 22.
Article in English | MEDLINE | ID: mdl-26703613

ABSTRACT

A new Raman-based apparatus for proximal detection of energetic materials on people, was developed and tested for the first time. All the optical and optoelectronics components of the apparatus, as well as their optical matching, were carefully chosen and designed to respect international eye-safety regulations. In this way, the apparatus is suitable for civil applications on people in public areas such as airports and metro or railway stations. The acquisition software performs the data analysis in real-time to provide a fast response to the operator. Moreover, it allows for deployment of the apparatus either as a stand alone device or as part of a more sophisticated warning system architecture made up of several sensors. Using polyamide as substrate, the apparatus was able to detect surface densities of ammonium nitrate (AN), 2-methyl-1,3,5-trinitrobenzene (TNT), 3-nitrooxy-2,2-bis(nitrooxymethyl)propyl] nitrate (PETN) and urea nitrate (UN) in the range of 100-1000 µg/cm² at a distance of 6.4 m using each time a single laser pulse of 3 mJ/cm². The limit of detection calculated for AN is 289 µg/cm². AN and UN provided the highest percentages of true positives (>82% for surface densities of 100-400 µg/cm² and fingerprints) followed by TNT and PETN (17%-70% for surface densities of 400-1000 µg/cm² and fingerprints).


Subject(s)
Environmental Monitoring/methods , Explosive Agents/analysis , Lasers , Spectrum Analysis, Raman/methods , Civil Defense , Environmental Monitoring/instrumentation , Humans , Terrorism/prevention & control
8.
Talanta ; 144: 420-6, 2015 Nov 01.
Article in English | MEDLINE | ID: mdl-26452842

ABSTRACT

We report the results of proximal Raman investigations at a distance of 7 m, to detect traces of explosives (from 0.1 to 0.8 mg/cm(2)) on common clothes with a new eye-safe apparatus. The instrument excites the target with a single laser shot of few ns (10(-9)s) in the UV range (laser wavelength 266 nm) detecting energetic materials like Pentaerythritol tetranitrate (PETN), Trinitrotoluene (TNT), Urea Nitrate (UN) and Ammonium Nitrate (AN). Samples were prepared using a piezoelectric-controlled plotter device to realize well-calibrated amounts of explosives on several cm(2). Common fabrics and tissues such as polyester, polyamide and leather were used as substrates, representative of base-materials used in the production of jackets or coats. Other samples were prepared by touching the substrate with a silicon finger contaminated with explosives, to simulate a spot left by contaminated hands on a jacket or bag during the preparation of an improvised explosive device (IED) by a terrorist. The observed Raman signals showed some peculiar molecular bands of the analyzed compounds, allowing us to identify and discriminate them with high sensitivity and selectivity, also in presence of the interfering signal from the underlying fabric. A dedicated algorithm was developed to remove noise and fluorescence background from the single laser shot spectra and an automatic spectral recognition procedure was also implemented, evaluating the intensity of the characteristic Raman bands of each explosive and allowing their automatic classification. Principal component analysis (PCA) was used to show the discrimination potentialities of the apparatus on different sets of explosives and to highlight possible criticalities in the detection. Receiver operating characteristic (ROC) curves were used to discuss and quantify the sensitivity and the selectivity of the proposed recognition procedure. To our knowledge the developed device is at the highest sensitivity nowadays achievable in the field of eye-safe, Raman devices for proximal detection.


Subject(s)
Explosive Agents/analysis , Eye , Principal Component Analysis , ROC Curve , Safety , Spectrum Analysis, Raman/instrumentation , Ultraviolet Rays , Limit of Detection
9.
Opt Lett ; 34(6): 800-2, 2009 Mar 15.
Article in English | MEDLINE | ID: mdl-19282937

ABSTRACT

The CO2 laser-based agile tuner lidar for atmospheric sensing has been used to profile the volcanic plume of Mount Etna during its most recent eruption. Owing to the transmitted wavelength, this system is practically insensitive to air molecules while it detects aerosol loads, and thus the path attenuation of the laser beam is strongly affected by volcanic particulate. Vertical profiles of extinction coefficient were retrieved up to an altitude above ground level of 5000 m. The observed extinction coefficient ranges from 10(-5) to 5x10(-4) m(-1). The lidar was able to accurately track the spatiotemporal evolution of the volcanic plume thanks to a spatial resolution of 15 m and a temporal resolution of 1 min.

10.
Appl Opt ; 47(24): 4405-12, 2008 Aug 20.
Article in English | MEDLINE | ID: mdl-18716647

ABSTRACT

A laser flow cytometer based on scanning flow cytometry has been assembled. The unpolarized and linearly polarized light-scattering profiles, as well as the side emitted light in different spectral bands, were measured, allowing the simultaneous and real-time determination of the effective size and the effective refractive index of each spherelike particle. Additionally, each particle could be identified from depolarization and fluorescence measured simultaneously. The tests with aqueous samples of polystyrene spheres, fluorescent or nonfluorescent, and phytoplankton cells demonstrate that the system is able to retrieve size and refractive index with an accuracy of 1% and that the depolarization and fluorescence measurements allow the classification of particles otherwise indistinguishable.

SELECTION OF CITATIONS
SEARCH DETAIL
...