Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
1.
J Invest Surg ; 35(2): 459-466, 2022 Feb.
Article in English | MEDLINE | ID: mdl-33377805

ABSTRACT

PURPOSE: To investigate the clinical effect of novel patient-specific 3D printing templates based on external fixation for pelvic screw insertion compared with the fluoro-navigation technique. MATERIALS AND METHODS: We retrospectively studied 18 pelvic fracture patients from July 2017 to July 2018. For analysis, patients were divided into two groups: the template group (15 screws in 8 patients) and the fluoro-navigation group (22 screws in 10 patients). The screw insertion time, radiation exposure time, and accuracy of the screw insertion as evaluated by postoperative CT scans were analyzed. RESULTS: In the template group, the average screw insertion time (11.5 ± 2.3 min/screw) was significantly 50.6% less than that in the fluoro-navigation group (23.3 ± 3.1 min/screw; P < 0.05). The average time of X-ray exposure in the template group (11.5 ± 3.9 s/screw) was also significantly 39.8% less than in the fluoro-navigation group (19.1 ± 2.5 s/screw; P < 0.05). In the template group, the mean deviation distance and angle between the actual and planned screw position was 2.6 ± 0.2 mm and 2 ± 0.3°. CONCLUSIONS: The patient-specific template based on external fixation can guide the insertion of the pelvic screw accurately and safely while significantly reducing operation and radiation exposure time.


Subject(s)
External Fixators , Surgery, Computer-Assisted , Bone Screws , Fracture Fixation , Fracture Fixation, Internal , Humans , Printing, Three-Dimensional , Retrospective Studies
2.
J Orthop Surg Res ; 15(1): 558, 2020 Nov 23.
Article in English | MEDLINE | ID: mdl-33228695

ABSTRACT

BACKGROUND: Several methods have been proposed to reduce plate construct stiffness and promote secondary bone healing. In this study, we explored the stiffness and strength of the new carbon fiber-reinforced poly-ether-ether-ketone (CF 50) plate compared with the titanium alloy plate (Ti6Al4V). METHODS: Titanium and CF-PEEK locking plates were tested in a tibial non-osteoporotic diaphyseal comminuted fracture model to determine construct stiffness in axial compression, torsion, and bending. Subsequently, constructs were loaded until construct failure to determine construct strength. RESULTS: Relative to the titanium locking plate, the stiffness of the CF-PEEK locking plate was 6.8% and 30.8% lower in 200 N and 700 N axial compression, respectively (P < 0.05), 64.9% lower in torsion (P < 0.05), and 48.9% lower in bending (P < 0.05). The strength of the CF-PEEK locking plate was only 2.6% lower under axial compression, 7.8% lower in torsion, and 4.8% lower in bending than the titanium locking plate (P > 0.05). CONCLUSIONS: The CF-PEEK locking plate significantly reduced axial, torsion, and bending stiffness compared with the titanium locking plate. Nonetheless, axial, torsional, and bending strength showed only a modest reduction. Considering its other advantages, which include radiolucency and artifact-free imaging, the CF-PEEK locking plate therefore deserves further clinical investigation.


Subject(s)
Bone Plates , Carbon Fiber , Fracture Fixation, Internal/methods , Fractures, Comminuted/surgery , Ketones , Polyethylene Glycols , Tibial Fractures/surgery , Titanium , Benzophenones , Biomechanical Phenomena , Fracture Healing , Fractures, Comminuted/physiopathology , Humans , Polymers , Tibial Fractures/physiopathology , Treatment Outcome
3.
Exp Ther Med ; 19(3): 2252-2258, 2020 Mar.
Article in English | MEDLINE | ID: mdl-32104291

ABSTRACT

As part of the treatment of pelvic fracture, major hemorrhage poses a challenge for trauma surgeons. The aim of the present study was to evaluate the clinical outcomes of blood transfusion in the initial 6 h after pelvic fracture, and to define the blood transfusion volume required for each pelvic fracture type. A retrospective cohort study was performed on patients with pelvic fracture at a single Level I Trauma Centre over a 3-year period. A total of 1,297 patients were transported to our trauma centre within 2 h of injury and blood transfusion was administered in the initial 6 h after pelvic fracture. Review of the patients' medical records provided the initial pelvic radiographs and data from emergency department care. Clinical outcomes, including frequency of blood transfusion, blood transfusion volume, injury severity scores and mortality, were evaluated. All pelvic fractures were defined as closed fractures and patients were categorized according to the Arbeit fuer Osteosynthese (AO) classification system. Statistical methods were used to identify trends to provide guidance for clinical prediction. Complete data were available for 497 patients with pelvic fracture, 104 (20.9%) of which received blood transfusion. The blood transfusion volume in the initial 6 h ranged from 0 to 10,000 ml, with a mean of 1,213.94±1354.11 ml. The total mortality rate was 1.8%. Among the patients with C-type pelvic fractures, the frequency of blood transfusion was 59.0% and the mean volume was 2,191.30±1,740.93 ml. The mortality rate for C-type pelvic fractures was 11.43%. The B3 subtype of pelvic fractures had the highest transfusion frequency (53.6%), while the C3 subtype had the largest blood transfusion volume (5,700.00±4,666.90 ml). Patients with type A-C pelvic fractures had a progressively larger mean transfusion volume, transfusion frequency and mortality in the initial 6 h after pelvic fracture. The AO classification system was demonstrated to be a useful tool for the identification of pelvic fracture risk in the present study.

4.
Arch Orthop Trauma Surg ; 138(8): 1097-1102, 2018 Aug.
Article in English | MEDLINE | ID: mdl-29748878

ABSTRACT

OBJECTIVES: To evaluate the methods and the outcomes of Gustilo type III open distal tibial and tibial shaft fractures with severe anterior and medial soft-tissue injuries, treated with posterolateral minimally invasive plate osteosynthesis (MIPO) technique. METHODS: From May 2015 to May 2016, 10 patients with Gustilo type III open distal tibial and tibial shaft fractures with severe anterior and medial soft-tissue injuries (Gustilo-Anderson classification IIIA, 6; IIIB, 4) were treated with staged protocol using posterolateral minimally invasive plate osteosynthesis (MIPO) technique. The initial wound lavage, debridement, and application of a spanning external fixator were performed within 24 h and the mean interval from injury to definitive surgical treatment was 12.8 (range 4-21) days. An additional bone graft was performed in two patients when definitive internal fixation was performed. All patients were followed to union. Postoperative radiographs, postoperative complications, bone union, ankle joint motion, and limb functional outcome information of AOFAS ankle-hindfoot score were recorded. RESULTS: The mean follow-up period was 17.8 (range 12-26) months. The mean interval to bony union was 25.8 (range 20-40) weeks. Bone union was achieved in all cases. There were no complications, such as incision breakdown, deep infection, or impingement of the flexor hallucis longus tendon. The average AOFAS score was 90 (range 83-96). In ten patients, two patients had a superficial wound infection and another one patient showed a 6° varus deformity. CONCLUSIONS: Staged treatment using MIPO technique through a posterolateral approach is a reasonable and safe treatment option for open distal tibial and tibial shaft fractures, especially Gustilo type III with severe anterior and medial soft-tissue injuries. However, it should have a higher level of research evidence in more patients to confirm the safety of the clinical application of this technique.


Subject(s)
Bone Plates , Fracture Fixation, Internal/methods , Fractures, Open/surgery , Minimally Invasive Surgical Procedures/methods , Tibial Fractures/surgery , Adult , Aged , Female , Follow-Up Studies , Fracture Fixation, Internal/instrumentation , Fractures, Open/diagnostic imaging , Humans , Male , Middle Aged , Minimally Invasive Surgical Procedures/instrumentation , Radiography , Tibial Fractures/diagnostic imaging , Treatment Outcome , Young Adult
5.
Injury ; 49(6): 1108-1112, 2018 Jun.
Article in English | MEDLINE | ID: mdl-29691041

ABSTRACT

OBJECTIVES: Although various implants exist for 3- and 4-part proximal humerus fractures, few implants are appropriate for humerus split type greater tuberosity fractures. The goal of this study was to assess the efficacy of pre-contoured anatomic locking plate for humerus split type greater tuberosity fractures. METHODS: A retrospective review of 68 patients with humerus split type greater tuberosity fractures treated with open reduction and internal fixation using anatomic locking plates between January 2014 and October 2016. Postoperatively, patient radiographs, functional results, and complications were reviewed. RESULTS: All patients got a mean follow-up of 30.5 months (range 14-46 months). Average fracture healing time was 9.4 weeks (range, 8-14 weeks). Overall mean Constant score was 86.8% (range, 70%-96%). The result was rated as excellent in 25 patients (Constant score: 92.1%), good in 38 patients (Constant score: 85.3%) moderate in 5 patients (Constant score: 71.8%) and poor in 0 cases. The excellent-good rate was 92.6%. No recurrence of dislocation occurred in the 30 cases with shoulder dislocation. All fractures healed without the complications of wound infection, subacromial impingement syndrome, nonunion, secondary displacement, and implant loosening. CONCLUSION: Pre-contoured anatomic locking plate is a reliable option in treating humerus split type greater tuberosity fractures as it provides stable fixation with an early return to function. The surgical technique is easy and efficient.


Subject(s)
Bone Plates , Fracture Fixation, Internal/instrumentation , Fracture Healing/physiology , Postoperative Complications/physiopathology , Shoulder Fractures/surgery , Adult , Aged , Female , Follow-Up Studies , Humans , Male , Middle Aged , Postoperative Complications/diagnostic imaging , Prospective Studies , Radiography , Retrospective Studies , Shoulder Fractures/diagnostic imaging , Shoulder Fractures/physiopathology , Treatment Outcome , Young Adult
6.
Medicine (Baltimore) ; 96(41): e8221, 2017 Oct.
Article in English | MEDLINE | ID: mdl-29019890

ABSTRACT

The aim of this study was to evaluate the clinical efficacy of external fixation, delayed open reduction, and internal fixation in treating tibial plateau fracture with dislocation.Clinical data of 34 patients diagnosed with tibial plateau fracture complicated with dislocation between January 2009 and May 2015 were retrospectively analyzed. Fifteen patients in group A underwent early calcaneus traction combined with open reduction and internal fixation and 19 in group B received early external fixation combined with delayed open reduction and internal fixation. Operation time, postoperative complication, bone healing time, knee joint range of motion, initial weight-bearing time, Rasmussen tibial plateau score, and knee function score (HSS) were statistically compared between 2 groups.The mean follow-up time was 18.6 months (range: 5-24 months). The mean operation time in group A was 96 minutes, significantly longer than 71 minutes in group B (P < .05). In group A, 5 cases had postoperative complications and 1 in group B (P < .05). The mean bone healing time in group A was 6.9 months (range: 5-9 months) and 6.0 months (range: 5-8 months) in group B (P > .05). In group A, initial weight-bearing time in group A was (14.0 ±â€Š3.6) weeks, significantly differing from (12.9 ±â€Š2.8) weeks in group B (P < 0.05). In group A, the mean knee joint range of motion was 122° (range: 95°-150°) and 135° (range: 100°-160°) in group B (P > 0.05). Rasmussen tibial plateau score in group A was slightly lower than that in group B (P > .05). The excellent rate of knee joint function in group A was 80% and 84.21% in group B (P > .05).External fixation combined with delayed open reduction and internal fixation is a safer and more efficacious therapy of tibial plateau fracture complicated with dislocation compared with early calcaneus traction and open reduction and internal fixation.


Subject(s)
Fracture Dislocation , Knee Joint , Open Fracture Reduction/methods , Postoperative Complications , Tibial Fractures , Adult , China/epidemiology , Female , Follow-Up Studies , Fracture Dislocation/diagnosis , Fracture Dislocation/physiopathology , Fracture Dislocation/surgery , Fracture Fixation, Internal/methods , Humans , Knee Joint/diagnostic imaging , Knee Joint/physiopathology , Male , Middle Aged , Operative Time , Outcome and Process Assessment, Health Care , Patient Care Management/methods , Postoperative Complications/diagnosis , Postoperative Complications/epidemiology , Range of Motion, Articular , Recovery of Function , Tibial Fractures/diagnosis , Tibial Fractures/epidemiology , Tibial Fractures/physiopathology , Tibial Fractures/surgery , Time Factors , Weight-Bearing
7.
Zhongguo Gu Shang ; 30(3): 208-212, 2017 Mar 25.
Article in Chinese | MEDLINE | ID: mdl-29349956

ABSTRACT

OBJECTIVE: To investigate the feasibility and therapeutic effect of subcutaneous pedicle screw-rod system with modified placement in treatment of Tile B pelvic fractures. METHODS: From June 2014 to August 2015, 14 patients with Tile B pelvic fractures were treated by subcutaneous pedicle screw-rod system with modified placement in the anterior inferior iliac spine and pubic tubercle. There were 8 males and 6 females, aged from 23 to 65 years with an average of 42 years. Operative time, intraoperative blood loss, fracture healing and postoperative complication were observed and clinical effects were evaluated by Matta reduction standard and Majeed score. RESULTS: All patients were followed up from 8 to 15 months with an average of 10.5 months. Operative time was 25 to 45 min with an average of 32 min;intraoperative blood loss was 10 to 35 ml with an average of 18 ml. All fractures got primary healing and healed time was 9 to 14 weeks with an average of 12.5 weeks. No postoperative incision infection, internal fixation failure and ectopic ossification were found, 4 cases occurred unilateral lateral femoral cutaneous nerve injury and 1 case occurred unilateral femoral nerve paralysis, but all restored finally. According to Matta criteria, reduction was excellent in 7 cases, good in 5 cases, fair in 2 case. According to Majeed score system, the functional evaluation at last follow-up was excellent in 5 cases, good in 7 cases, fair in 2 cases with the average score of 81.50±8.05. CONCLUSIONS: Subcutaneous pedicle screw-rod system with modified placement in the anterior inferior iliac spine and pubic tubercle have advantages of strong reduction, less trauma and complications, and is a promising surgical method in the treatment of Tile B pelvic fractures.


Subject(s)
Fracture Fixation, Internal , Fractures, Bone/surgery , Pedicle Screws , Pelvic Bones/injuries , Adult , Aged , Feasibility Studies , Female , Humans , Ilium/surgery , Male , Middle Aged , Pubic Bone/surgery , Treatment Outcome
8.
Indian J Orthop ; 50(3): 250-5, 2016.
Article in English | MEDLINE | ID: mdl-27293284

ABSTRACT

BACKGROUND: The incidence of pelvic fractures in trauma patients is reported to be 3-8.2%, with roughly half of these fractures being caused by high energy injuries with a potential for catastrophic hemorrhage and death. Indications for internal fixation of anterior pelvic ring are controversial. Because of fears of disturbing the pelvic hematoma and causing additional hemorrhage, open reduction and internal fixation of pelvic ring disruption is routinely delayed. In contrast to conventional surgery, percutaneous screw fixation is gaining popularity in the treatment of pelvic and acetabular fractures mainly because of minimal soft tissue damage, less operative blood loss, early surgical intervention and comfortable mobilization of the patient. Fluoro-navigation is a new surgical technique in orthopedic trauma surgery. This study is to investigate clinical results of fluoro-navigation surgery in anterior pelvic ring fractures. MATERIALS AND METHODS: From January 2006 to October 2011, 23 patients with anterior pelvic ring fractures were treated with percutaneous cannulated screw under fluoro-navigation. There were 14 men and 9 women, with a mean age of 40.1 years (range 25-55). According to the AO and Orthopedic Trauma Association classification, there were seven A 2.1, two A 2.2, one A 2.3, six B 1.2, one B 2.1: 1, one B 2.2, one C 1.2, two C 1.3 and two C 2.3 types of fractures. Amongst these patients, 13 had posterior pelvic ring injuries, 8 had other injuries including urethral, lumbar vertebrae fractures and femoral fractures. All patients were operated when their general condition stabilized after emergency management. The mean time from injury to percutaneous screw fixation of the anterior pelvic ring fracture was 12 days (3-15 days). All the anterior ring fractures were fixed with cannulated screws by two senior surgeons. They were familiar with the navigation system and had gained much experience in the computer-assisted percutaneous placement of screws. RESULTS: A total of 32 screws were inserted, including 19 in the pubic ramis and 13 in the anterior acetabular columns. The average surgical time was 23.3 min/screw. The average time of X-ray exposure was 19.1 ± 2.5 s/screw. The virtual images of fluoro-navigation were compared with real-time X-rays during and after the surgery. Compared to the final position of the screw, the average deviated distance was 3.11 mm and the average trajectory difference was 2.81°. Blood loss during the operation was minimal (22.3 ml/screw). One screw (3.1%) deviated out of the fracture site during the operation. No superficial or deep infection occurred. No patient sustained recognized neurologic, vascular, or urologic injury as a result of the percutaneous screw fixation. All fractures united at the last followup. CONCLUSIONS: Fluoro-navigation technique could become a safe, accurate, and fairly quick method for the treatment of anterior pelvic ring fractures. Standardization of the operative procedure and training are mandatory for the success of this procedure.

9.
Exp Ther Med ; 10(1): 295-299, 2015 Jul.
Article in English | MEDLINE | ID: mdl-26170952

ABSTRACT

The transcription factor, CCAAT-enhancer-binding protein homologous protein (CHOP), is induced by endoplasmic reticulum-stress and mediates programmed cell death. In osteoblasts, CHOP overexpression increases the rate of apoptosis, leading to osteoblastic dysfunction. However, the regulatory mechanisms underlying CHOP expression remain unclear. In the present study, western blot analysis was used to demonstrate that the activation of signal transducer and activator of transcription 3 (STAT3) inhibited the levels of the CHOP protein, whereas small interfering RNA-mediated the knockdown of STAT3 upregulated CHOP expression. Furthermore, STAT3 was shown to increase the expression level of microRNA (miR)-205. A luciferase reporter assay revealed that miR-205 was able to directly target the 3'-untranslated region of the CHOP gene to inhibit its protein expression. The miR-205 antisense largely abolished the inhibitory effect of STAT3 activation on the levels of CHOP protein. Therefore, the results demonstrated a previously unknown STAT3/miR-205/CHOP signaling pathway in osteoblasts, which may aid the understanding of the pathogenic mechanisms of associated diseases, including osteoporosis.

SELECTION OF CITATIONS
SEARCH DETAIL
...