ACS Nano ; 18(21): 13899-13909, 2024 May 28.
Article in English | MEDLINE | ID: mdl-38757652

ABSTRACT

The ability to precisely identify crystal orientation as well as to nondestructively modulate optical anisotropy in atomically thin rhenium dichalcogenides is critical for the future development of polarization programmable optoelectronic devices, which remains challenging. Here, we report a modified polarized optical imaging (POI) method capable of simultaneously identifying in-plane (Re chain) and out-of-plane (c-axis) crystal orientations of the monolayer to few-layer ReS2, meanwhile, propose a nondestructive approach to modulate the optical anisotropy in ReS2 via twist stacking. The results show that parallel and near-cross POI are effective to independently identify the in-plane and out-of-plane crystal orientations, respectively, while regulating the twist angle allows for giant modulation of in-plane optical anisotropy from highly intrinsic anisotropy to complete optical isotropy in the stacked ReS2 bilayer (with either the same or opposite c-axes), as well modeled by linear electromagnetic theory. Overall, this study not only develops a simple optical method for precise crystal orientation identification but also offers an efficient light polarization control strategy, which is a big step toward the practical application of anisotropic van der Waals materials in the design of nanophotonic and optoelectronic devices.

2.
Small ; : e2308809, 2023 Dec 02.
Article in English | MEDLINE | ID: mdl-38041445

ABSTRACT

The rational design of absorber size is a promising strategy for obtaining excellent electromagnetic wave (EMW) absorption performance. However, achieving controllable tuning of the material size through simple methods is challenging and the associated EMW attenuation mechanisms are still unclear. In this study, the sizes of metal-organic frameworks (MOFs) are successfully tailored by changing the growth time and the molar ratio of iron (Fe)/organic ligands. The lateral and vertical lengths of MOFs vary in the range of 200 nm to 2 µm and 100 nm to 1 µm, respectively. Both experiments and simulations confirm that the decrease of MOF size favors the formation of more conductive networks, which is beneficial for improving the conductivity loss. Meanwhile, the micromagnetic simulation reveals that the magnetic coupling can be effectively enhanced by the decrease of MOF size, which is conducive to the improvement of magnetic loss, especially in low-frequency range. The reflection loss of Fe-based MOFs with optimized size reaches -46.4 dB at 6.2 GHz with an effective absorption bandwidth of 3.1 GHz. This work illustrates the important role of size effect in EMW dissipation and provides an effective strategy for enhancing the low-frequency EMW absorption performance.

3.
RSC Adv ; 13(29): 20248-20254, 2023 Jun 29.
Article in English | MEDLINE | ID: mdl-37425625

ABSTRACT

We have investigated a micro vapor membrane valve (MVMV) for closing the microfluidic channels by laser irradiation on carbon nanocoils (CNCs) attached to the inner wall of the microchannels. The microchannel with MVMVs was found to exhibit a "closed" state without the supply of laser energy, which is explained on the basis of the theory of heat and mass transfer. Multiple MVMVs for sealing the channels can be generated in sequence and exist simultaneously at different irradiation sites, independently. The significant advantages of the MVMV generated by the laser irradiation on CNCs are the elimination of extrinsic energy required to maintain the microfluidic channel "closed" state and the simplification of the structure integrated into the microfluidic channels and fluid control circuitries. The CNC-based MVMV is a powerful tool for the investigations of the functions of microchannel switching and sealing on microfluidic chips in biomedicine, chemical analysis and other fields. The study of MVMVs will have great significance for biochemical and cytological analysis.

4.
Small ; 19(36): e2301992, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37127857

ABSTRACT

High-performance microwave absorption (MA) materials have attracted more and more attention because they can effectively prevent microwave radiation and interference from electronic devices. Herein, a new type of MA composite is constructed by introducing carbon nanotubes (CNTs)-anchored metal-organic framework derivatives (MOFDs) into a conductive carbon nanocoil (CNC) network, denoted as CNC/CNT-MOFD. The CNC/MOFD shows a wide effective absorption band of 6.7 GHz under a filling ratio of only 9% in wax-matrix. This is attributed to the hierarchical and porous structures of MOFD bridged by the uniformly dispersed conductive CNC network and the cross-polarization induced by the 3D spiral CNCs. Besides, the as-grown 1D CNTs improve space utilization, porosity, and polarization loss of the composites, resulting in the increase of imaginary permittivity, which further realizes impedance matching and energy attenuation. The Ni nanoparticles in layers of MOFD and at the tips of CNTs generate magnetic loss, promoting the low-frequency absorption ability. Resultantly, RCS values of the optimized composite in all tested theta (θ) ranges are less than -25 dB m2 at 9.5 GHz, effectively reducing the probability of the target detected by the radar.

5.
Nanomaterials (Basel) ; 12(15)2022 Jul 30.
Article in English | MEDLINE | ID: mdl-35957060

ABSTRACT

A flexible and stretchable electrode based on polydimethylsiloxane (PDMS)-Ag nanosheet composite with low resistance and stable properties has been investigated. Under the synergistic effect of the excellent flexibility and stretchability of PDMS and the excellent electrical conductivity of Ag nanosheets, the electrode possesses a resistivity as low as 4.28 Ωm, a low resistance variation in the 0-50% strain range, a stable electrical conductivity over 1000 cycles, and a rapid recovery ability after failure caused by destructive large stretching. Moreover, the conductive mechanism of the flexible electrode during stretching is explained by combining experimental tests, theoretical models of contact point-tunneling effect, and finite element simulation. This research provides a simple and effective solution for the structure design and material selection of flexible electrodes, and an analytical method for the conductive mechanism of stretchable electrodes, which has potential for applications in flexible electronic devices, smart sensing, wearable devices, and other fields.

6.
Anal Chim Acta ; 1224: 340201, 2022 Sep 01.
Article in English | MEDLINE | ID: mdl-35998986

ABSTRACT

The sensitivity of surface enhanced Raman spectroscopy (SERS) depends on the construction of "hot spots" and the number of analyte molecules adsorbed onto the substrates. Herein, we have constructed a kind of SERS substrate based on gold nanostars (Au NSs) coated with nickel-cobalt layered double hydroxide (LDH) using a zeolitic imidazolate skeleton as sacrificial template via nickel ions etching. LDH was used as the absorption medium for target molecules, and concurrently prevented Au NSs from agglomeration to improve stability and uniformity of the substrate. Meanwhile, encapsulated Au NSs were used as the enhancement medium for Raman detection. The porous LDH shell around the Au NSs promoted the target molecules to approach the Au NSs, which was certified by the experimental results of UV-Vis absorption and simulation analysis using the density functional theory. The detection of Rhodamine 6G solution with a concentration of 10-9 M was realized by the AuNS/LDH, and the relative standard deviation of Raman signals was less than 10%. Therefore, this work provides a new idea and a suitable structure to improve SERS signal intensity by introducing adsorption medium into the SERS substrate.


Subject(s)
Metal Nanoparticles , Spectrum Analysis, Raman , Adsorption , Gold/chemistry , Metal Nanoparticles/chemistry , Nickel , Spectrum Analysis, Raman/methods
7.
J Colloid Interface Sci ; 624: 320-337, 2022 Oct 15.
Article in English | MEDLINE | ID: mdl-35660901

ABSTRACT

Bimetallic nanostructures composited with carbonaceous materials are the potential contenders for quantitative glucose measurement owing to their unique nanostructures, high biomimetic activity, synergistic effects, good conductivity and chemical stability. In the present work, chemical vapors deposition technique has been employed to grow 3D carbon nanocoils (CNCs) with a chiral morphology on hierarchical macroporous nickel foam (NF) to get a CNCs/NF scaffold. Following, bimetallic Cu@Ni core-shell nanoparticles (CSNPs) are effectively coupled with this scaffold through a facile solvothermal route in order to fabricate a binder-free novel Cu@Ni CSNPs/CNCs/NF hybrid nanostructure. The constructed free-standing 3D hierarchical composite electrode guarantees highly efficient glucose redox activity due to core-shell synergistic effects, enhanced electrochemical active surface area, excellent electrochemical stability, improved conductivity with better ion diffusivity and accelerated reaction kinetics. Being a non-enzymatic glucose sensor, this electrode achieves highly swift response time of 0.1 s, ultra-high sensitivity of 6905 µA mM-1 cm-2, low limit of detection of 0.03 µM along with potential selectivity and good storage stability. Moreover, the proposed sensor is also tested successfully for the determination of glucose concentration in human serum samples under good recovery ranging from 96.6 to 102.1 %. The 3D Cu@Ni CSNPs/CNCs/NF composite electrode with unprecedented catalytic performance can be utilized as an ideal biomimetic catalyst in the field of non-enzymatic glucose sensing.


Subject(s)
Nanoparticles , Nickel , Carbon , Electrochemical Techniques/methods , Electrodes , Glucose , Humans , Nickel/chemistry
8.
Nanoscale ; 14(18): 7025-7038, 2022 May 16.
Article in English | MEDLINE | ID: mdl-35471502

ABSTRACT

A flexible humidity sensor based on a tissue-carbon nanocoil (CNC)-carbon nanotube (CNT) composite has been investigated. Taking advantage of the excellent water absorption of tissue and the electrical sensitivity of CNCs/CNTs to humidity, this humidity sensor obtains outstanding humidity sensing performance, including a wide sensing range of 10-90% RH, a maximum response value of 492% (ΔR/R0) at 90% RH, a maximum sensitivity of 6.16%/% RH, a good long-time stability of more than 7 days, a high humidity resolution accuracy of less than 1% RH and a fast response time of 275 ms. Furthermore, the sensor also exhibits robust bending (with a curvature of 0.322 cm-1) and folding (up to 500 times) durability, and after being made into a complex "thousand paper crane" shape it still provides stable humidity sensing performance. As a proof of concept, this humidity sensor demonstrates excellent responsivity to human breath monitoring, non-contact fingertip humidity detection, water boiling detection and air humidity monitoring, indicating great potential in the fields of wearable devices, weather forecasting systems and other intelligent humidity monitoring devices.

9.
ACS Appl Mater Interfaces ; 14(15): 17330-17339, 2022 Apr 20.
Article in English | MEDLINE | ID: mdl-35384670

ABSTRACT

Recently, wearable energy harvesting systems have been attracting great attention. As thermal energy is abundant in nature, developing wearable energy harvesters based on thermal energy conversion processes has been of particular interest. By integration of a high-efficient solar absorber, a pyroelectric film, and thermoelectric yarns, herein, we design a novel wearable solar-energy-driven pyrothermoelectric hybrid generator (PTEG). In contrast to those wearable pyroelectric generators and thermoelectric generators reported in previous works, our PTEG can enable effective energy harvesting from both dynamic temperature fluctuations and static temperature gradients. Under an illumination intensity of 1500 W/m2 (1.5 sun), the PTEG successfully charges two commercial capacitors to a sum voltage of 3.7 V in only 800 s, and the total energy is able to light up 73 LED light bulbs. The volumetric energy density over the two capacitors is calculated to be 67.8 µJ/cm3. The practical energy harvesting performance of the PTEG is further evaluated in the outdoor environment. The PTEG reported in this work not only demonstrates a rational structural design of high-efficient wearable energy harvesters but also paves a new pathway to integrate multiple energy conversion technologies for solar energy collection.

10.
J Colloid Interface Sci ; 608(Pt 2): 1894-1906, 2022 Feb 15.
Article in English | MEDLINE | ID: mdl-34752977

ABSTRACT

Surface modification and composition control for nanomaterials are effective strategies for designing high-performance microwave absorbing materials (MWAMs). Herein, we have successfully fabricated Co-anchored and N-doped carbon layers on the surfaces of helical carbon nanocoils (CNCs) by wet chemical and pyrolysis methods, denoted as Co@N-Carbon/CNCs. It is found that pure CNCs show a very good microwave absorption performance under a filling ratio of only 6%, which is attributed to the uniformly dispersed conductive network and the cross polarization induced by the unique chiral and spiral morphology. The coating of N-doped carbon layers on CNCs further enriches polarization losses and the uniform anchoring of Co nanoparticles in these layers generates magnetic losses, which enhance the absorption ability and improve the low frequency performance. As compared with the pure CNCs-filling samples, the optimized Co@N-Carbon/CNCs-2.4 enhances the absorption capacity in the lower frequency range under the same thickness, and realizes the decreased thickness from 3.2 to 2.8 mm in the same X band, as well as the decreased thickness from 2.2 to 1.9 mm in the Ku band. Resultantly, a specific effective absorption wave value of 22 GHz g-1 mm-1 has been achieved, which enlightens the synthesis of ultrathin and light high-performance MWAMs.

11.
Membranes (Basel) ; 11(10)2021 Oct 16.
Article in English | MEDLINE | ID: mdl-34677554

ABSTRACT

Lightweight energy storage devices with high mechanical flexibility, superior electrochemical properties and good optical transparency are highly desired for next-generation smart wearable electronics. The development of high-performance flexible and transparent electrodes for supercapacitor applications is thus attracting great attention. In this work, we successfully developed flexible, transparent and highly conductive film electrodes based on a conducting polymer, poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS). The PEDOT:PSS film electrodes were prepared via a simple spin-coating approach followed by a post-treatment with a salt solution. After treatment, the film electrodes achieved a high areal specific capacitance (3.92 mF/cm2 at 1 mA/cm2) and long cycling lifetime (capacitance retention >90% after 3000 cycles) with high transmittance (>60% at 550 nm). Owing to their good optoelectronic and electrochemical properties, the as-assembled all-solid-state device for which the PEDOT:PSS film electrodes were utilized as both the active electrode materials and current collectors also exhibited superior energy storage performance over other PEDOT-based flexible and transparent symmetric supercapacitors in the literature. This work provides an effective approach for producing high-performance, flexible and transparent polymer electrodes for supercapacitor applications. The as-obtained polymer film electrodes can also be highly promising for future flexible transparent portable electronics.

12.
Nanoscale ; 13(27): 11943-11952, 2021 Jul 15.
Article in English | MEDLINE | ID: mdl-34198318

ABSTRACT

Well-organized substrate materials are of considerable significance in the development of energy-efficient pseudocapacitor electrodes. Herein, functionalized three-dimensional (3D) carbon nanocoils on nickel foam (CNCs/NF) have been used as the substrate to grow faradaic nickel cobaltite (NiCo2O4) via a solvothermal method. The arrays of NiCo2O4 were assembled by interconnected ultrathin nanosheets with random inter-particle pores. The number of electroactive sites increased specifically because of the porous feature of NiCo2O4 nanosheets and the 3D structure of CNCs/NF. Moreover, the CNCs/NF network aided the electrolyte ions in diffusing deeply within the architecture. The NiCo2O4/CNCs/NF composite exhibited an outstanding specific capacitance of 2821 F g-1 at the current density of 1 A g-1, a remarkable rate capability (82.4%) and long cyclic stability (91.7% after 3000 cycles). Such encouraging electrochemical performance was attributed mainly to the synergistic interactions of NiCo2O4 arrays and CNCs/NF substrate that helped achieve efficient redox reactions, enhanced ion diffusivity and excellent electron conductivity. In summary, this binder-free NiCo2O4/CNCs/NF composite electrode paves a way towards the synthesis of highly efficacious electrodes for supercapacitors.

13.
Nanomicro Lett ; 13(1): 144, 2021 Jun 15.
Article in English | MEDLINE | ID: mdl-34138390

ABSTRACT

Recently, multilevel structural carbon aerogels are deemed as attractive candidates for microwave absorbing materials. Nevertheless, excessive stack and agglomeration for low-dimension carbon nanomaterials inducing impedance mismatch are significant challenges. Herein, the delicate "3D helix-2D sheet-1D fiber-0D dot" hierarchical aerogels have been successfully synthesized, for the first time, by sequential processes of hydrothermal self-assembly and in-situ chemical vapor deposition method. Particularly, the graphene sheets are uniformly intercalated by 3D helical carbon nanocoils, which give a feasible solution to the mentioned problem and endows the as-obtained aerogel with abundant porous structures and better dielectric properties. Moreover, by adjusting the content of 0D core-shell structured particles and the parameters for growth of the 1D carbon nanofibers, tunable electromagnetic properties and excellent impedance matching are achieved, which plays a vital role in the microwave absorption performance. As expected, the optimized aerogels harvest excellent performance, including broad effective bandwidth and strong reflection loss at low filling ratio and thin thickness. This work gives valuable guidance and inspiration for the design of hierarchical materials comprised of dimensional gradient structures, which holds great application potential for electromagnetic wave attenuation.

14.
J Mater Chem B ; 9(13): 3088-3096, 2021 04 07.
Article in English | MEDLINE | ID: mdl-33885670

ABSTRACT

Hydrogels with specially designed structures and adjustable properties have been considered as smart materials with multi-purpose application prospects, especially in the field of flexible sensors. However, most hydrogel-based sensors have low sensitivity, which inevitably affects their promotion in the market. Herein, a strain sensor comprising a poly(vinyl alcohol)/poly(acrylic acid) (PVA/PAA) hybrid hydrogel sandwiched between two graphene layers was successfully constructed in a facile way, and it exhibited many excellent properties including extremely high sensitivity. The incorporation of glycerol ensured the good flexibility and anti-freezing performance of the hydrogel-based sensor even at -15 °C. The dynamic coordination bonds in the hydrogel-based sensor endowed it with excellent self-healing properties. In particular, the sandwich-structured hydrogel sensor showed a very high gauge factor (GF) value of 39 at the strain of 50%, which is much higher than those of most ordinary hydrogel-based strain sensors. A super stable signal value after 5000 strain cycles and a very short response time of 274 ms guaranteed the long-term usability and sensitivity of the hydrogel-based sandwich sensor. More importantly, the hydrogel-based sandwich sensor could detect both large and tiny human motions accurately and instantly in a series of real-time monitoring experiments, showing great potential for intelligent wearable electronic devices.


Subject(s)
Acrylic Resins/chemistry , Freezing , Graphite/chemistry , Hydrogels/chemistry , Polyvinyl Alcohol/chemistry , Wearable Electronic Devices , Humans , Hydrogels/chemical synthesis
15.
Anal Chim Acta ; 1154: 338323, 2021 Apr 15.
Article in English | MEDLINE | ID: mdl-33736799

ABSTRACT

Au Nanostar (NS) monolayer as a surface enhanced Raman scattering (SERS) substrate has been synthesized by self-assembly at a water-oil interface. It is confirmed from the experiment and simulation results that the Au NS monolayer includes lots of "hot spots" at or between the tips of the Au NSs, enhancing the local electromagnetic fields and giving rise to strong SERS signals sequentially. The limit of detection is determined to be down to 4.2 × 10-12 M for rhodamine 6G. Furthermore, the Au NS monolayer can detect multiple molecules, including thiabendazole, methylene blue, 4-mercaptobenzoic acid, and p-amino thiophenol, indicating that the SERS substrate composed of Au NS monolayer has potential applications in analytical chemistry, food safety, and environmental safety.

16.
ACS Sens ; 6(3): 1120-1128, 2021 03 26.
Article in English | MEDLINE | ID: mdl-33724004

ABSTRACT

The wearable and self-powered sensors with multiple functions are urgently needed for energy saving devices, economical convenience, and artificial human skins. It is a meaningful idea to convert excess heat sources into power supplies for wearable sensors. In this report, we have fabricated a series of free-standing self-powered temperature-strain dual sensors based on poly(3,4-ethylenedioxythiophene) polystyrenesulfonate (PEDOT:PSS)/carbon nanocoils (CNCs)-poly(vinyl) alcohol composite films by a simple drop casting method. The Seebeck coefficients of the composite films were measured to be 19 µV/K. The sensor, with the addition of CNCs, showed a superior sensing performance to that without CNCs. PEDOT:PSS is used to provide a thermoelectric power to detect temperature changes and strain deformations. The minimum detect limit for the temperature difference was 0.3 K. Under a constant temperature gradient of 30 K, strains from 1 to 10% were detected without any external power supply. The films can be easily made into an array to detect the temperature of the fingers and motions of the wrist by attaching it to the human wrist directly. For the first time, due to the independent action of the thermoelectric material and strain sensing material, the thermoelectric voltage which is generated by a constant temperature difference is maintained under different strains. This kind of free-standing self-powered multifunctional sensors has great application prospects in the fields of healthcare and artificial intelligence in the future.


Subject(s)
Wearable Electronic Devices , Artificial Intelligence , Bridged Bicyclo Compounds, Heterocyclic , Carbon , Humans , Polymers , Polyvinyl Alcohol , Temperature
17.
Sci Rep ; 11(1): 5044, 2021 03 03.
Article in English | MEDLINE | ID: mdl-33658569

ABSTRACT

Non-enzymatic electrochemical detection of catechol (CC) and hydroquinone (HQ), the xenobiotic pollutants, was carried out at the surface of novel carbon nanocoils/zinc-tetraphenylporphyrin (CNCs/Zn-TPP) nanocomposite supported on glassy carbon electrode. The synergistic effect of chemoresponsive activity of Zn-TPP and a large surface area and electron transfer ability of CNCs lead to efficient detection of CC and HQ. The nanocomposite was characterized by using FT-IR, UV/vis. spectrophotometer, SEM and energy dispersive X-ray spectroscopy (EDS). Cyclic voltammetry, differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy were used for the electrochemical studies. CNCs/Zn-TPP/GCE nanosensor displayed a limit of detection (LOD), limit of quantification (LOQ) and sensitivity for catechol as 0.9 µM, 3.1 µM and 0.48 µA µM-1 cm-2, respectively in a concentration range of 25-1500 µM. Similarly, a linear trend in the concentration of hydroquinone detection was observed between 25 and 1500 µM with an LOD, LOQ and sensitivity of 1.5 µM, 5.1 µM and 0.35 µA µM-1 cm-2, respectively. DPV of binary mixture pictured well resolved peaks with anodic peak potential difference, ∆Epa(CC-HQ), of 110 mV showing efficient sensing of CC and HQ. The developed nanosensor exhibits stability for up to 30 days, better selectivity and good repeatability for eight measurements (4.5% for CC and 5.4% for HQ).

18.
Nanomaterials (Basel) ; 10(11)2020 Oct 27.
Article in English | MEDLINE | ID: mdl-33121162

ABSTRACT

Amorphous structures may play important roles in achieving highly efficient microwave absorption performance due to the polarization losses induced by the disorders, vacancies and other functional groups existed in them. Herein, a kind of amorphous TiO2/rGO composite (a-TiO2/rGO) was successfully fabricated via a facile one-step solvothermal method. The complex permittivity of the composites can be regulated by adjusting the addition of precursor solution. The minimum reflection loss of a-TiO2/rGO composites reached -42.8 dB at 8.72 GHz with a thickness of 3.25 mm, and the widest efficient absorption bandwidth (EAB) was up to 6.2 GHz (11.8 to 18 GHz) with a thickness of only 2.15 mm, which achieved the full absorption in Ku band (12 to 18 GHz). Furthermore, the EAB was achieved ranging from 3.97 to 18 GHz by adjusting the thickness of the absorber, covering 87.7% of the whole radar frequency band. It is considered that the well-matched impedance, various polarization processes, capacitor-like structure and conductive networks all contributed to the excellent microwave absorption of a-TiO2/rGO. This study provides reference on constructing amorphous structures for future microwave absorber researches and the as-prepared a-TiO2/rGO composites also have great potential owing to its facile synthesis and highly efficient microwave absorption.

19.
ACS Appl Mater Interfaces ; 12(17): 19874-19881, 2020 Apr 29.
Article in English | MEDLINE | ID: mdl-32253911

ABSTRACT

Recently, wearable strain sensors have increasingly attracted much attention due to their potential applications in human motion detection and personal health monitoring. To date, it is still a challenge to fabricate a flexible strain sensor with both comfort and high performance. In this study, we dip the commercially available spandex/polyamide fabric into carbonic pen ink to prepare a textile strain sensor with good skin affinity. The textile strain sensor exhibits a high gauge factor (∼62.9) and an excellent linearity (R2 ∼ 0.99) in the strain range of 0-30%. Both before and after washing, the sensor exhibits high stability in more than 5000 cycles. Owing to the facile integration of the ink-decorated fabric on clothes, the sensor can be conveniently attached to the human body to monitor human motions, thus showing great potential in practical applications.


Subject(s)
Carbon/chemistry , Ink , Monitoring, Physiologic/instrumentation , Movement , Stress, Mechanical , Wearable Electronic Devices , Humans , Polyurethanes/chemistry , Textiles
20.
Sci Rep ; 10(1): 2315, 2020 Feb 11.
Article in English | MEDLINE | ID: mdl-32047199

ABSTRACT

A novel carbon nanotubes (CNTs) and reduced holey graphene oxide film (RHGOF) sandwich structure has been fabricated to enhance its electrochemical properties. CNTs are grown by a catalyst assisted chemical vapor deposition technique, interpenetrated between the RHGOF layers. A RHGOF/CNTs hybrid film is used as a binder-free supercapacitor electrode. The grown CNTs in the graphene layers structure act as spacers and bridges to increase the counductivity of RHGOF, while the grown CNTs on the surfaces of the graphene contribute to increase the specific surface area of RHGOF. The results demonstrate that the synthesized porous, flexible and binder free hybrid electrode has advantages of higher ion diffusion rate, longer diffusion length and larger ion accessible surface area as compared to the pristine graphene which results in an extra ordinary galvanostatic charge-discharge specific capacitance of 557 F/g at a current density of 0.5 A/g, with excellent rate capabilities and superior cyclic stabilities.