1.
Clin Chem Lab Med ; 2024 Jul 22.
Article in English | MEDLINE | ID: mdl-39027966

ABSTRACT

OBJECTIVES: This article defines analytical performance specifications (APS) for evaluating laboratory proficiency through an external quality assessment scheme. METHODS: Standard deviations for proficiency assessment were derived from Thompson's characteristic function applied to robust data calculated from participants' submissions in the Occupational and Environmental Laboratory Medicine (OELM) external quality assurance scheme for trace elements in serum, whole blood and urine. Characteristic function was based on two parameters: (1) ß - the average coefficient of variation (CV) at high sample concentrations; (2) α - the average standard deviation (SD) at low sample concentrations. APSs were defined as 1.65 standard deviations calculated by Thompson's approach. Comparison between OELM robust data and characteristic function were used to validate the model. RESULTS: Application of the characteristic function allowed calculated APS for 18 elements across three matrices. Some limitations were noted, particularly for elements (1) with no sample concentrations near analytical technique limit of detection; (2) exhibiting high robust CV at high concentration; (3) exhibiting high analytical variability such as whole blood Tl and urine Pb; (4) with an unbalanced number of robust SD above and under the characteristic function such as whole blood Mn and serum Al and Zn. CONCLUSIONS: The characteristic function was a useful means of deriving APS for trace elements in biological fluids where biological variation data or outcome studies were not available. However, OELM external quality assurance scheme data suggests that the characteristic functions are not appropriate for all elements.

2.
Adv Lab Med ; 4(4): 379-386, 2023 Dec.
Article in English | MEDLINE | ID: mdl-38106488

ABSTRACT

Objectives: The results of external quality assurance schemes are evaluated against specifications generally based on biological variation (BV) data. This study was carried out to determine whether new BV values affected the level of compliance to specifications. Our secondary objective was to identify the conditions that would be compromised as a result of poor analytical performance in disease associated markers. Methods: This study was based on the results of the SEQCML External Quality Assurance scheme for the 2015-2022 period. Deviation of the individual result from the target value was estimated. Additionally, we calculated the percentage of results that met the pre-established specification. Results: In 97 of the 133 analytes, the level of compliance was maintained in 80-90 % of the results obtained in the two study periods. In 23 analytes, the level of compliance ranged from 51 to 79 % in the two study periods. In ALT, AST and sodium, the level of compliance was ≤50 % of the results obtained in the first study period, with sodium being the only analyte that maintained this poor level of compliance in the second study period. Conclusions: The level of compliance to specifications remained independent from the specification used (SEQCML or EFLM) for the majority of the analytes. The results for sodium ion were below the target value, which may lead to misdiagnosis of hyponatremia. Non-compensated alkaline picrate methods overestimate creatinine, which may produce false information suggestive of kidney failure.

SELECTION OF CITATIONS
SEARCH DETAIL
...