Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Database
Language
Publication year range
1.
Food Chem ; 463(Pt 4): 141427, 2024 Sep 24.
Article in English | MEDLINE | ID: mdl-39348768

ABSTRACT

A sensitive dual immunochromatographic test strip (dual-ICTS) was developed to detect malachite green (MG) and its metabolite, leucomalachite green (LMG), using two types of gold nanoparticles: round-shaped (red) and star-shaped (blue). The detection limits were determined to be 0.221 µg L-1 for MG and 0.214 µg L-1 for LMG, respectively. The dual-ICTS provided a cut-off value of 1.8 µg L-1 for MG and LMG detection. The dual-ICTS successfully detected MG and LMG in food samples, with recovery rates ranging from 86 % to 116 %. The dual-ICTS was evaluated by correlation analysis between the proposed assay and the well-established enzyme-linked immunosorbent assay in the MG and LMG detection. This is the first report on the development of the ICTS that can detect both MG and LMG at the same time within only 5 min, making it a sensitive and rapid tool for on-site detection.

2.
Anal Chim Acta ; 1285: 342031, 2024 Jan 02.
Article in English | MEDLINE | ID: mdl-38057063

ABSTRACT

A novel immunochromatographic assay (ICA) based on hyperbranched Au plasmonic blackbodies (AuPBs) with a smartphone readout was fabricated for the detection of leucomalachite green (LMG) in fish and shrimp products. The ICA was carried out in a competitive immunoassay format with AuPBs as labels. The developed AuPBs-ICA allowed for the LMG detection with a low detection limit (0.15 µg L-1) within 5 min by the smartphone reader. With the label-AuPBs ICA, the color intensity response was linearly related to the concentrations of the LMG (0.2 -1.7 µg L-1). The test line signal could be clearly distinguished at a 1.7 µg L-1 LMG as a cut-off level by the naked eye, which is lower than the conventional colloidal gold nanoparticle (2 µg L-1) and star-shaped nanoparticles (1.9 µg L-1) labeling. LMG contamination in samples was determined with the proposed AuPBs-ICA and the enzyme-linked immunosorbent (ELISA). The AuPBs-ICA results showed good agreement with those from the ELISA. The proposed AuPBs-ICA has the potential to be used as a rapid, sensitive, and simple device for the analysis of LMG residues in fish and shrimp samples.


Subject(s)
Gold , Metal Nanoparticles , Animals , Metal Nanoparticles/chemistry , Seafood/analysis , Immunoassay , Limit of Detection
SELECTION OF CITATIONS
SEARCH DETAIL