J Synchrotron Radiat ; 21(Pt 3): 580-5, 2014 May.
Article in English | MEDLINE | ID: mdl-24763648

ABSTRACT

Far-infrared spectroscopy, using a synchrotron source, has been used to study carbon steel corroded in CO2-saturated brine in the presence and absence of the corrosion inhibitor 2-mercaptopyrimidine (MPY), which allowed the steel surface roughness to be modified. The effect of the angle of incidence (θi, 30-80°) on the band intensity and observed bands of the spectra from these surfaces has been determined. For the MPY-treated steel (low surface roughness) the highest band intensity is observed at high θi (80°) and different bands were observed at different θi. In contrast, for the MPY-free steel (high surface roughness) the highest band intensity is observed at low θi (30°) and spectral content changes were not observed. The results are explained in terms of the roughness of the MPY-treated and MPY-free steels, and their effect on the level of diffusely reflected light of the incident infrared beam.