Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add more filters










Database
Language
Publication year range
3.
Semin Intervent Radiol ; 38(5): 560-564, 2021 Dec.
Article in English | MEDLINE | ID: mdl-34853502

ABSTRACT

A wide variety of wires are available for use in interventional radiology, with wires demonstrating differences in construction, diameter, length, coating, shape, and taper. It is crucial to understand the difference in characteristics between these wires to select the most effective and safe wire for the intended purpose when undertaking a procedure. This article reviews the qualities and functions of different types of wires to aid in this decision-making process.

5.
Semin Intervent Radiol ; 37(1): 3-13, 2020 Mar.
Article in English | MEDLINE | ID: mdl-32139965

ABSTRACT

Emergent transjugular intrahepatic portosystemic shunt (TIPS) creation is most commonly employed in the setting of acute variceal hemorrhage. Given a propensity for decompensation, these patients often require a multidisciplinary, multimodal approach involving prompt diagnosis, pharmacologic therapy, and endoscopic intervention. While successful in the majority of cases, failure to medically control initial bleeding can prompt interventional radiology consultation for emergent portal decompression via TIPS creation. This article discusses TIPS creation in emergent, acute variceal hemorrhage, reviewing the natural history of gastroesophageal varices, presentation and diagnosis of acute variceal hemorrhage, pharmacologic therapy, endoscopic approaches, patient selection and risk stratification for TIPS, technical considerations for TIPS creation, adjunctive embolotherapy, and the role of salvage TIPS versus early TIPS in acute variceal hemorrhage.

6.
Semin Intervent Radiol ; 37(1): 74-84, 2020 Mar.
Article in English | MEDLINE | ID: mdl-32139973

ABSTRACT

Pyonephrosis is gross accumulation of pus within an obstructed renal collecting system that, if left untreated, can lead to potentially fatal septic shock. Treatment requires urgent decompression coupled with systemic antibiotics. Percutaneous nephrostomy (PCN) placement, first described in 1976 for the treatment of pyonephrosis, is now widely utilized for emergent decompression in these patients. When performed by an experienced interventional radiologist, PCN is a safe procedure with technical success rates of over 96 to 99%. This article will address the clinical presentation of pyonephrosis, and will discuss the indications, technique, complications, and outcomes of emergent PCN placement. Additionally, the expanded indications for PCN placement in nonemergent scenarios will also be described.

7.
Semin Intervent Radiol ; 35(3): 169-184, 2018 Aug.
Article in English | MEDLINE | ID: mdl-30087520

ABSTRACT

Variceal hemorrhage is a feared complication of portal hypertension, with high rates of morbidity and mortality. Optimal management requires a thoughtful, multidisciplinary approach. In cases of refractory or recurrent esophageal hemorrhage, endovascular approaches such as transjugular intrahepatic portosystemic shunt (TIPS) have a well-defined role. For hemorrhage related to gastric varices, the optimal treatment remains to be established; however, there is increasing adoption of balloon-occluded retrograde transvenous obliteration (BRTO). This article will review the concept, history, patient selection, basic technique, and outcomes for TIPS, BRTO, and combined TIPS + BRTO procedures for variceal hemorrhage.

8.
Radiographics ; 37(4): 1236-1245, 2017.
Article in English | MEDLINE | ID: mdl-28696849

ABSTRACT

Use of retrievable inferior vena cava filters (RIVCFs) has grown exponentially since their introduction into clinical practice, but many of these devices are not retrieved. Some are not retrieved due to poor clinical follow-up, but other devices remain in situ for extended periods because they present significant technical challenges during retrieval. Because of these and other factors, many of these devices were thus left in place permanently. However, recent data have placed a renewed emphasis on device retrieval due to increased risk of RIVCF-related complications, which are positively correlated with filter dwell time. Development of advanced filter retrieval techniques has had a significant impact on the removal of embedded RIVCFs, permitting retrieval of the majority of devices. The purpose of this article is to present an imaging and data review of the dominant device-related factors that complicate RIVCF retrieval and to describe the relevant advanced retrieval techniques to manage these factors. RIVCF imaging is frequently encountered in daily clinical practice via various imaging modalities. Therefore, diagnostic radiologists can play a vital role in identifying filter-related issues. Familiarity with the context for managing these issues in the interventional suite is essential for improving triage and care of patients with RIVCFs. © RSNA, 2017.


Subject(s)
Device Removal/methods , Diagnostic Imaging , Vena Cava Filters/adverse effects , Vena Cava, Inferior/diagnostic imaging , Humans , Time Factors
9.
Semin Intervent Radiol ; 33(2): 71-4, 2016 Jun.
Article in English | MEDLINE | ID: mdl-27247473

ABSTRACT

Cancer induces a hypercoagulable state and renders patients susceptible to venous thromboembolism. While anticoagulation remains the mainstay of treatment, many of these patients require placement of an inferior vena cava (IVC) filter, often due to a contraindication to or failure of anticoagulation. In this article, the available data on IVC filter usage in cancer patients will be reviewed.

SELECTION OF CITATIONS
SEARCH DETAIL
...