Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Int J Hyperthermia ; 39(1): 490-496, 2022.
Article in English | MEDLINE | ID: mdl-35285391

ABSTRACT

OBJECTIVE: To investigate the efficacy of radiofrequency ablation (RFA) as a treatment option for primary hyperparathyroidism (pHPT) and risk factors for postablative eucalcemic parathyroid hormone elevation (ePTH). METHODS: This retrospective study included 51 patients with pHPT who underwent RFA. The patients were divided into the ePTH and normal PTH groups, based on the serum intact parathyroid hormone (iPTH) level one month after ablation. Serum iPTH, calcium, and phosphorus levels, and the volume reduction rates (VRR) of the parathyroid glands were compared between the groups at each follow-up point. Risk factors for ePTH at one month after ablation were examined. RESULTS: After RFA, one (2%) patient had persistent pHPT, and 50 (98%) patients were cured. The incidence rates of ePTH at 1, 3, 6, and 12 months were 48%, 30%, 20%, and 16%, respectively. Serum iPTH levels in the ePTH group were higher than those in the normal PTH group at each follow-up point (all p < 0.05), except 1 day after ablation (p > 0.05). Serum calcium and phosphorus levels, and the VRR of the glands were comparable in both groups at each follow-up point (all p > 0.05), except for calcium levels 3 days after RFA (p < 0.05). Baseline iPTH (odds ratio, 1.067; p = 0.045) and calcium (odds ratio, 3.923; p = 0.038) levels were independent risk factors for ePTH 1 month after RFA. CONCLUSIONS: RFA is safe and effective for the treatment of pHPT. Moreover, ePTH occurrence after RFA was associated with baseline iPTH and calcium levels and did not increase the risk of recurrent pHPT.


Subject(s)
Hyperparathyroidism, Primary , Radiofrequency Ablation , Calcium , Humans , Hyperparathyroidism, Primary/surgery , Parathyroid Hormone , Parathyroidectomy , Radiofrequency Ablation/adverse effects , Retrospective Studies , Risk Factors
2.
J Ultrasound Med ; 39(4): 775-784, 2020 Apr.
Article in English | MEDLINE | ID: mdl-31675129

ABSTRACT

OBJECTIVES: To evaluate the performance of fetal intelligent navigation echocardiography (FINE) applied to spatiotemporal image correlation (STIC) volumes in generating 3 specific abnormal cardiac views (left ventricular outflow tract, right ventricular outflow tract, and 3-vessel and trachea) used to screen for d-transposition of the great arteries (d-TGA). METHODS: In this prospective study, 1 or more STIC volumes were obtained from the 4-chamber view in 34 second- and third-trimester fetuses with d-TGA. Each appropriate STIC volume was evaluated by STICLoop (Samsung Medison, Seoul, Korea) before applying the FINE method. One optimal volume per fetus was selected by observers. The visualization rates of the 3 specific abnormal cardiac views of d-TGA and their diagnostic elements were calculated, and the reliability between 2 observers was verified by the intraclass correlation coefficient. RESULTS: Fetal intelligent navigation echocardiography applied to STIC volume data sets of fetuses with d-TGA successfully generated the 3 specific abnormal cardiac views in the following manner for 2 observers: 75.0% (n = 21) for the left ventricular outflow tract, 89.2% (n = 25) for the right ventricular outflow tract, and 85.7% (n = 24) for the 3-vessel and trachea view. Twenty-four (85.7%) of the STIC volume data sets showed 2 or 3 of the abnormal cardiac views. The interobserver intraclass correlation coefficients between the 2 observers ranged from 0.842 to 1.000 (95% confidence interval), indicating almost perfect reliability for the 2 observers. CONCLUSIONS: In cases of d-TGA, the FINE method has a high success rate in generating 3 specific abnormal cardiac views and therefore can be performed to screen for this congenital defect.


Subject(s)
Echocardiography/methods , Fetal Heart/diagnostic imaging , Transposition of Great Vessels/diagnostic imaging , Transposition of Great Vessels/embryology , Ultrasonography, Prenatal/methods , Female , Fetal Heart/embryology , Humans , Pregnancy , Prospective Studies , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL
...