ABSTRACT
OBJECTIVES: This study sought to evaluate the accuracy and errors of linear measurements of mesiodistal dimensions of Kennedy Class III edentulous space using cone beam computed tomography (CBCT) in comparison with clinical measurements. MATERIALS AND METHODS: Nineteen Kennedy Class III dental arches were evaluated. An impression was made of each dental arch and poured with dental stone. The distance was measured on dental cast using a digital Vernier caliper with an accuracy of 0.1mm and on CBCT scans. Finally, the linear mesiodistal measurements were compared and the accuracy of CBCT technique was evaluated by calculating absolute value of errors, intra-class correlation coefficient and simple linear regression model. RESULTS: In comparison with the cast method, estimation of size on CBCT scans had an error of -8.46% (underestimation) to 5.21% (overestimation). In 26.5% of the cases, an accepted error of ±1% was found. The absolute value of errors was found to be in the range of 0.21-8.46mm with an average value of 2.86 ±2.30mm. CONCLUSIONS: Although the measurements revealed statistically significant differences, this does not indicate a lower accuracy for the CBCT technique. In fact, CBCT can provide some information as a paraclinical tool and the clinician can combine these data with clinical data and achieve greater accuracy. Undoubtedly, calibration of data collected by clinical and paraclinical techniques and the clinician's expertise in use of CBCT software programs can increase the accuracy of implant placement.
ABSTRACT
PURPOSE: The purpose of the present study was to compare the crestal bone loss around implants placed according to either a 1-stage or 2-stage implant installation procedure using a digital subtraction radiography technique. MATERIALS AND METHODS: In the present randomized clinical trial, screw-shaped tapered implants were inserted in the posterior mandible of patients needing fixed partial dentures. In each edentulous area, according to the randomization table, 1 implant was inserted using a 1-stage procedure (group 1) and 1 was placed using a 2-stage approach (group 2). The implants were temporized with the relined denture after 2 weeks. All implants were functionally loaded with fixed partial dentures after 3 months. Crestal bone loss (primary outcome variable) was measured using a digital subtraction radiography technique. Standardized radiovisiographs were taken after implant insertion, after fixed partial denture installation (3 months after surgery), and after 6 and 12 months of functional loading. The data were analyzed using the Wilcoxon signed ranks test (α = 0.05). RESULTS: Eleven patients (mean age 46.9 years, 3 women and 8 men) were included in the study. A total of 34 implants were inserted, 17 using a 1-stage protocol and 17 using a 2-stage protocol. Three months after implant placement, the 2-stage implants showed significantly more crestal bone loss (0.65 ± 0.71 mm) than the 1-stage implants (0.41 ± 0.53 mm; P = .02). However, after 6 and 12 months of functional loading, both groups showed comparable changes in bone level (P > .05). CONCLUSIONS: No differences were found between 1-stage and 2-stage implant placement in crestal bone loss after 1 year of functional loading.