Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 33
Filter
1.
medRxiv ; 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38633802

ABSTRACT

Pathogens encapsulate or encode their own suite of enzymes to facilitate replication in the host. The pathogen-derived enzymes possess specialized activities that are essential for pathogen replication and have naturally been candidates for drug targets. Phenotypic assays detecting the activities of pathogen-derived enzymes and characterizing their inhibition under drugs offer an opportunity for pathogen detection, drug resistance testing for individual patients, and as a research tool for new drug development. Here, we used HIV as an example to develop assays targeting the reverse transcriptase (RT) enzyme encapsulated in HIV for sensitive detection and phenotypic characterization, with the potential for point-of-care (POC) applications. Specifically, we targeted the complementary (cDNA) generation activity of the HIV RT enzyme by adding engineered RNA as substrates for HIV RT enzyme to generate cDNA products, followed by cDNA amplification and detection facilitated by loop-mediated isothermal amplification (LAMP) or CRISPR-Cas systems. To guide the assay design, we first used qPCR to characterize the cDNA generation activity of HIV RT enzyme. In the LAMP-mediated Product-Amplified RT activity assay (LamPART), the cDNA generation and LAMP amplification were combined into one pot with novel assay designs. When coupled with direct immunocapture of HIV RT enzyme for sample preparation and endpoint lateral flow assays for detection, LamPART detected as few as 20 copies of HIV RT enzyme spiked into 25µL plasma (fingerstick volume), equivalent to a single virion. In the Cas-mediated Product-Amplified RT activity assay (CasPART), we tailored the substrate design to achieve a LoD of 2e4 copies (1.67fM) of HIV RT enzyme. Furthermore, with its phenotypic characterization capability, CasPART was used to characterize the inhibition of HIV RT enzyme under antiretroviral drugs and differentiate between wild-type and mutant HIV RT enzyme for potential phenotypic drug resistance testing. Moreover, the CasPART assay can be readily adapted to target the activity of other pathogen-derived enzymes. As a proof-of-concept, we successfully adapted CasPART to detect HIV integrase with a sensitivity of 83nM. We anticipate the developed approach of detecting enzyme activity with product amplification has the potential for a wide range of pathogen detection and phenotypic characterization.

2.
JHEP Rep ; 6(4): 101020, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38515553

ABSTRACT

Background & Aims: Alcohol-associated liver diseases (ALDs) and alcohol use disorder (AUD) pose a global health risk. AUD is underrecognized in the elderly, and the burden of AUD complications, including ALD, may increase with aging populations and rising alcohol intake. However, there is a lack of epidemiological evidence on AUD and ALD in the elderly. Methods: Using the Global Burden of Disease Study 2019, we analyzed the prevalence, mortality, disability-adjusted life years (DALYs), age-standardized rates (ASRs), and temporal change from 2000 to 2019 of ALD and AUD in the overall population and the elderly (65-89 years). The findings were categorized by sex, region, nation, and sociodemographic index. Results: The prevalence rates of ALD in the elderly were higher than those in adolescents and young adults, whereas AUD levels were lower than those in adolescents and young adults. In 2019, there were 9.39 million cases (8.69% of cases in the overall population) of AUD, 3.23 million cases (21.8% of cases in the overall population) of alcohol-associated cirrhosis, and 68,468 cases (51.27% of cases in the overall population) of liver cancer from alcohol among the elderly. ASRs of the prevalence of ALD and AUD in the elderly increased in most regions; on the contrary, ASRs of death and DALYs decreased in most regions. Nevertheless, ASRs of death and DALYs from liver cancer from alcohol increased in many areas. Conclusions: Our findings highlighted the increased prevalence of ALD in the elderly, with a burden of AUD comparable with that in the overall population. Public health strategies on ALD and AUD targeting the elderly are urgently needed. Impact and implications: The burden of alcohol-associated liver disease (ALD) and alcohol use disorder (AUD) is increasing. Advances in healthcare and education have resulted in a remarkable spike in life expectancy and a consequential population aging. Nevertheless, little is known about the epidemiology of ALD and AUD in the elderly. Our study indicates the increasing burden of ALD and AUD in the elderly population, necessitating early detection, intervention, and tailored care to the unique needs and complexities faced by older individuals grappling with these conditions.

3.
AIDS ; 38(1): 39-47, 2024 Jan 01.
Article in English | MEDLINE | ID: mdl-37773037

ABSTRACT

OBJECTIVES: The aim of this study was to assess the level and correlates of biomarker-confirmed adherence to isoniazid (INH) preventive therapy (IPT) among children with HIV (CLHIV). DESIGN: This prospective cohort study assessed adherence among CLHIV on IPT in public sector HIV clinics from 2019 through 2020. METHODS: Adherence was assessed by pill counts or caregiver or self-reports, and urine biomarkers (in-house dipstick and Isoscreen). Both urine biomarker tests detect INH metabolites within 48 h of ingestion. Consistent adherence was defined as having positive results on either biomarker at all visits. Correlates of biomarker-confirmed nonadherence at each visit were evaluated using generalized estimating equations. The in-house dipstick was validated using Isoscreen as the reference. RESULTS: Among 97 CLHIV on IPT with adherence assessments, median age was 10 years (IQR 7-13). All were on ART at IPT initiation (median duration 46 months [IQR 4-89]); 81% were virally suppressed (<1000 copies/ml). At all visits, 59% ( n  = 57) of CLHIV reported taking at least 80% of their doses, while 39% ( n  = 38) had biomarker-confirmed adherence. Viral nonsuppression (adjusted risk ratio [aRR] = 1.65; 95% confidence interval [95% CI] 1.09-2.49) and the sixth month of IPT use (aRR = 2.49; 95% CI 1.34-4.65) were independent correlates of biomarker-confirmed nonadherence at each visit. Sensitivity and specificity of the in-house dipstick were 98.1% ( 94.7 - 99.6%) and 94.7% ( 88.1 - 98.3%) , respectively, versus Isoscreen. CONCLUSION: Biomarker-confirmed adherence to IPT was sub-optimal and was associated with viral nonsuppression and duration of IPT. Urine dipstick testing may be useful in assessing adherence to IPT in clinical care.


Subject(s)
HIV Infections , Tuberculosis , Child , Humans , Isoniazid/therapeutic use , Antitubercular Agents/therapeutic use , Tuberculosis/diagnosis , Tuberculosis/prevention & control , Tuberculosis/drug therapy , Prospective Studies , Kenya , HIV Infections/drug therapy , HIV Infections/prevention & control , Biomarkers
4.
Am J Gastroenterol ; 119(5): 893-909, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38147513

ABSTRACT

INTRODUCTION: The burden of alcohol-related complications is considerable, particularly alcohol-associated liver disease and alcohol use disorder (AUD). However, there are deficiencies in comprehensive epidemiological research focusing on these issues, especially among young women who display higher susceptibility to such complications compared with their male counterparts. We thus aimed to determine the global burden of these conditions in this vulnerable group. METHODS: Leveraging data from the Global Burden of Disease Study 2019, we analyzed the prevalence, mortality, and disability-adjusted life years of alcohol-associated cirrhosis (AC), liver cancer from alcohol, and AUD in young women. The findings were categorized by region, nation, and sociodemographic index. RESULTS: The highest age-standardized prevalence rates were observed in AUD (895.96 [95% uncertainty interval (UI) 722.6-1,103.58]), followed by AC (65.33 [95% UI 48.37-86.49]) and liver cancer from alcohol (0.13 [95% UI 0.09-0.19]) per 100,000 people. The highest age-standardized mortality rates were observed in AC (0.75 [95% UI 0.55-0.97]), followed by AUD (0.48 [95% UI 0.43-0.53]) and liver cancer from alcohol (0.06 [95% UI 0.04-0.09]). The highest burdens of AC and AUD were observed in Central Europe, whereas the high-income Asia Pacific had the highest burden of liver cancer from alcohol. DISCUSSION: Throughout the past decade, the trend of AUD varied among regions while the impact of alcohol-associated liver disease has increased, requiring urgent public health strategy to mitigate these complications, particularly in female patients in Europe and the Asia-Pacific region.


Subject(s)
Alcoholism , Global Burden of Disease , Liver Diseases, Alcoholic , Liver Neoplasms , Humans , Female , Adult , Alcoholism/epidemiology , Alcoholism/complications , Prevalence , Liver Diseases, Alcoholic/epidemiology , Liver Diseases, Alcoholic/mortality , Liver Neoplasms/epidemiology , Disability-Adjusted Life Years , Young Adult , Cost of Illness , Middle Aged , Global Health
5.
Diagnostics (Basel) ; 13(19)2023 Sep 25.
Article in English | MEDLINE | ID: mdl-37835783

ABSTRACT

Since SARS-CoV-2 is a highly transmissible virus, a rapid and accurate diagnostic method is necessary to prevent virus spread. We aimed to develop and evaluate a new rapid colorimetric reverse transcription loop--mediated isothermal amplification (RT-LAMP) assay for SARS-CoV-2 detection in a single closed tube. Nasopharyngeal and throat swabs collected from at-risk individuals testing for SARS-CoV-2 were used to assess the sensitivity and specificity of a new RT-LAMP assay against a commercial qRT-PCR assay. Total RNA extracts were submitted to the RT-LAMP reaction under optimal conditions and amplified at 65 °C for 30 min using three sets of specific primers targeting the nucleocapsid gene. The reaction was detected using two different indicator dyes, hydroxynaphthol blue (HNB) and cresol red. A total of 82 samples were used for detection with HNB and 94 samples with cresol red, and results were compared with the qRT-PCR assay. The sensitivity of the RT-LAMP-based HNB assay was 92.1% and the specificity was 93.2%. The sensitivity of the RT-LAMP-based cresol red assay was 80.3%, and the specificity was 97%. This colorimetric feature makes this assay highly accessible, low-cost, and user-friendly, which can be deployed for massive scale-up and rapid diagnosis of SARS-CoV-2 infection, particularly in low-resource settings.

6.
Anal Chim Acta ; 1277: 341674, 2023 Oct 09.
Article in English | MEDLINE | ID: mdl-37604625

ABSTRACT

Lateral flow assays (LFAs) provide a simple and quick option for diagnosis and are widely adopted for point-of-care or at-home tests. However, their sensitivity is often limited. Most LFAs only allow 50 µL samples while various sample types such as saliva could be collected in much larger volumes. Adapting LFAs to accommodate larger sample volumes can improve assay sensitivity by increasing the number of target analytes available for detection. Here, a simple agglutination system comprising biotinylated antibody (Ab) and streptavidin (SA) is presented. The Ab and SA agglutinate into large aggregates due to multiple biotins per Ab and multiple biotin binding sites per SA. Dynamic light scattering (DLS) measurements showed that the agglutinated aggregate could reach a diameter of over 0.5 µm and over 1.5 µm using poly-SA. Through both experiments and Monte Carlo modeling, we found that high valency and equivalent concentrations of the two aggregating components were critical for successful agglutination. The simple agglutination system enables antigen capture from large sample volumes with biotinylated Ab and a swift transition into aggregates that can be collected via filtration. Combining the agglutination system with conventional immunoassays, an agglutination assay is proposed that enables antigen detection from large sample volumes using an in-house 3D-printed device. As a proof-of-concept, we developed an agglutination assay targeting SARS-CoV-2 nucleocapsid antigen for COVID-19 diagnosis from saliva. The assay showed a 10-fold sensitivity enhancement when increasing sample volume from 50 µL to 2 mL, with a final limit of detection (LoD) of 10 pg mL-1 (∼250 fM). The assay was further validated in negative saliva spiked with gamma-irradiated SARS-CoV-2 and showed an LoD of 250 genome copies per µL. The proposed agglutination assay can be easily developed from existing LFAs to facilitate the processing of large sample volumes for improved sensitivity.


Subject(s)
COVID-19 Testing , COVID-19 , Humans , COVID-19/diagnosis , SARS-CoV-2 , Antibodies , Biotin , Agglutination
7.
Cureus ; 15(5): e38998, 2023 May.
Article in English | MEDLINE | ID: mdl-37323313

ABSTRACT

Introduction Early-onset colorectal cancer (EOCRC) is becoming a growing concern due to its increased incidence among younger individuals, particularly in areas with limited healthcare access and funding, such as in countries with a low sociodemographic index (SDI). However, there are limited studies regarding this problem. Therefore, our study primarily aims to address the dearth of knowledge in this area by assessing the trends in EOCRC in low SDI countries over 10 years. Methods In this study, we analyzed data from the Global Burden of Disease Study 2019 to investigate the changes in EOCRC over time in low SDI countries. Our analysis involved determining the yearly frequencies and age-standardized rates (ASRs) of EOCRC incidence, death, and disability-adjusted life years (DALYs) by gender. Results In 2019, the number of newly diagnosed EOCRC cases in low SDI countries was 7,716, while the global cases were 225,736. The incidence rates of EOCRC increased significantly higher in low SDI countries compared to the global average between 2010 and 2019, with a 1.38-fold higher increase among females. Mortality rates and DALYs also increased in the low SDI countries, with the annual percentage change from 2010 to 2019 of 0.96 (95% uncertainty interval (UI): 0.88-1.03) and 0.91 (95% UI: 0.83-0.98), respectively. Conclusion Our research highlights a significant rise in CRC in low SDI countries, particularly in the female population. Therefore, it emphasizes the need for prompt and efficient interventions, including but not limited to effective screening methods and mitigation of risk factors.

8.
AIDS ; 36(14): 1949-1958, 2022 11 15.
Article in English | MEDLINE | ID: mdl-36305180

ABSTRACT

OBJECTIVES: Assess the impact of pre-treatment high-frequency and low-frequency drug-resistant HIV variants on long-term outcomes of first-line efavirenz-based antiretroviral therapy (ART). DESIGN: Prospective observational study. METHODS: Participants' pre-treatment plasma RNA had two sections of HIV pol encoding reverse transcriptase sequenced (Illumina, MiSeq) using unique molecular identifiers to detect wild-type (pre-treatment drug-resistant variants less than 1% of viral quasispecies), low-frequency (1-9%) or high-frequency drug-resistant variants (10-100%). Associations between pre-treatment drug resistance and virologic outcomes over 24 months of efavirenz-based ART were assessed for the number and frequency of mutations by drug class and other resistance parameters. RESULTS: Virologic failure was detected in 30 of 352 (9%) and pre-treatment drug-resistant variants were detected in the viral quasispecies of 31 of 352 (9%) participants prescribed efavirenz-based ART. Survival analyses revealed statistically significant associations between pre-treatment drug resistance at low (P < 0.0001) and high (P < 0.001) frequencies, at oligonucleotide ligation assay (OLA) (P < 0.00001) and non-OLA (P < 0.01) codons, to a single-antiretroviral class (P < 0.00001), and a shorter time to virologic failure of efavirenz-based ART. Regression analyses detected independent effects across resistance categories, including both low-frequency (P < 0.01) and high-frequency (P < 0.001) drug-resistant variants. CONCLUSION: We observed that pre-treatment HIV drug resistance detected at low frequencies increased the risk of virologic failure over 24 months of efavirenz-based ART, but that most failures, regardless of drug-resistant variants' frequencies, were detected within a year of ART initiation. These observations suggest that when efavirenz-based ART is prescribed, screening for pre-treatment drug resistance by an assay capable of detecting low-frequency variants, including OLA, may guide clinicians to prescribe more effective ART.


Subject(s)
Anti-HIV Agents , Drug Resistance, Viral , HIV Infections , Humans , Anti-HIV Agents/therapeutic use , HIV Infections/drug therapy , HIV Reverse Transcriptase/genetics , HIV-1/genetics , Treatment Failure
10.
Microbiol Spectr ; 10(4): e0158321, 2022 08 31.
Article in English | MEDLINE | ID: mdl-35708340

ABSTRACT

The increasing prevalence of variant lineages during the COVID-19 pandemic has the potential to disrupt molecular diagnostics due to mismatches between primers and variant templates. Point-of-care molecular diagnostics, which often lack the complete functionality of their high-throughput laboratory counterparts, are particularly susceptible to this type of disruption, which can result in false-negative results. To address this challenge, we have developed a robust Loop Mediated Isothermal Amplification assay with single tube multiplexed multitarget redundancy and an internal amplification control. A convenient and cost-effective target-specific fluorescence detection system allows amplifications to be grouped by signal using adaptable probes for pooled reporting of SARS-CoV-2 target amplifications or differentiation of the Internal Amplification Control. Over the course of the pandemic, primer coverage of viral lineages by the three redundant sub-assays has varied from assay to assay as they have diverged from the Wuhan-Hu-1 isolate sequence, but aggregate coverage has remained high for all variant sequences analyzed, with a minimum of 97.4% (Variant of Interest: Eta). In three instances (Delta, Gamma, Eta), a high-frequency mismatch with one of the three sub-assays was observed, but overall coverage remained high due to multitarget redundancy. When challenged with extracted human samples the multiplex assay showed 87% or better sensitivity (of 30 positive samples), with 100% sensitivity for samples containing greater than 30 copies of viral RNA per reaction (of 21 positive samples), and 100% specificity (of 60 negative samples). These results are further evidence that conventional laboratory methodologies can be leveraged at the point of care for robust performance and diagnostic stability over time. IMPORTANCE The COVID-19 pandemic has had tremendous impact, and the ability to perform molecular diagnostics in resource limited settings has emerged as a key resource for mitigating spread of the disease. One challenge in COVID-19 diagnosis, as well as other viruses, is ongoing mutation that can allow viruses to evade detection by diagnostic tests. We developed a test that detects multiple parts of the virus genome in a single test to reduce the chance of missing a virus due to mutation, and it is designed to be simpler and faster than typical laboratory tests while maintaining high sensitivity. This capability is enabled by a novel fluorescent probe technology that works with a simple constant temperature reaction condition.


Subject(s)
COVID-19 , SARS-CoV-2 , COVID-19/diagnosis , COVID-19 Testing , Clinical Laboratory Techniques/methods , Fluorescent Dyes , Humans , Molecular Diagnostic Techniques/methods , Nucleic Acid Amplification Techniques , Pandemics , SARS-CoV-2/genetics , Sensitivity and Specificity
11.
Analyst ; 147(14): 3315-3327, 2022 Jul 12.
Article in English | MEDLINE | ID: mdl-35762367

ABSTRACT

The COVID-19 pandemic interrupted routine care for individuals living with HIV, putting them at risk of virologic failure and HIV-associated illness. Often this population is at high risk for exposure to SARS-CoV-2 infection, and once infected, for severe disease. Therefore, close monitoring of HIV plasma viral load (VL) and screening for SARS-CoV-2 infection are needed. We developed a non-proprietary method to isolate RNA from plasma, nasal secretions (NS), or both. The extracted RNA is then submitted to RT-qPCR to estimate the VL and classify HIV/SARS-CoV-2 status (i.e., HIV virologic failure or suppressed; SARS-CoV-2 as positive, presumptive positive, negative, or indeterminate). In contrived samples, the in-house RNA extraction workflow achieved a detection limit of 200-copies per mL for HIV RNA in plasma and 100-copies per mL for SARS-CoV-2 RNA in NS. Similar detection limits were observed for HIV and SARS-CoV-2 in pooled plasma/NS contrived samples. When comparing in-house with standard extraction methods, we found high agreement (>0.91) between input and measured RNA copies for HIV LTR in contrived plasma; SARS-CoV-2 N1/N2 in contrived NS; and LTR, N1, and N2 in pooled plasma/NS samples. We further evaluated this workflow on 133 clinical specimens: 40 plasma specimens (30 HIV-positive), 67 NS specimens (31 SARS-CoV-2-positive), and 26 combined plasma/NS specimens (26 HIV-positive with 10 SARS-CoV-2-positive), and compared the results obtained using the in-house RNA extraction to those using a commercial kit (standard extraction method). The in-house extraction and standard extraction of clinical specimens were positively correlated: plasma HIV VL (R2 of 0.81) and NS SARS-CoV-2 VL (R2 of 0.95 and 0.99 for N1 and N2 genes, respectively); and pooled plasma/NS HIV VL (R2 of 0.71) and SARS-CoV-2 VL (R2 of 1 both for N1 and N2 genes). Our low-cost molecular test workflow ($1.85 per pooled sample extraction) for HIV RNA and SARS-CoV-2 RNA could serve as an alternative to current standard assays ($12 per pooled sample extraction) for laboratories in low-resource settings.


Subject(s)
COVID-19 , HIV Infections , COVID-19/diagnosis , HIV Infections/diagnosis , Humans , Pandemics , RNA, Viral/analysis , SARS-CoV-2/genetics , Sensitivity and Specificity , Viral Load/methods , Workflow
12.
Anal Chem ; 94(20): 7278-7285, 2022 05 24.
Article in English | MEDLINE | ID: mdl-35532905

ABSTRACT

The COVID-19 pandemic is among the greatest health and socioeconomic crises in recent history. Although COVID-19 vaccines are being distributed, there remains a need for rapid testing to limit viral spread from infected individuals. We previously identified the SARS-CoV-2 spike protein N-terminal domain (NTD) binding DNA aptamer 1 (SNAP1) for detection of SARS-CoV-2 virus by aptamer-antibody sandwich enzyme-linked immunoassay (ELISA) and lateral flow assay (LFA). In this work, we identify a new aptamer that also binds at the NTD, named SARS-CoV-2 spike protein NTD-binding DNA aptamer 4 (SNAP4). SNAP4 binds with high affinity (<30 nM) for the SARS-CoV-2 spike protein, a 2-fold improvement over SNAP1. Furthermore, we utilized both SNAP1 and SNAP4 in an aptamer sandwich LFA (AptaFlow), which detected SARS-CoV-2 UV-inactivated virus at concentrations as low as 106 copies/mL. AptaFlow costs <$1 per test to produce, provides results in <1 h, and detects SARS-CoV-2 at concentrations that indicate higher viral loads and a high probability of contagious transmission. AptaFlow is a potential approach for a low-cost, convenient antigen test to aid the control of the COVID-19 pandemic.


Subject(s)
Aptamers, Nucleotide , COVID-19 , Antibodies, Viral , Aptamers, Nucleotide/chemistry , COVID-19/diagnosis , COVID-19 Vaccines , Humans , Pandemics , SARS-CoV-2 , Spike Glycoprotein, Coronavirus
14.
Sci Transl Med ; 14(646): eabn1252, 2022 05 25.
Article in English | MEDLINE | ID: mdl-35412328

ABSTRACT

New variants of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) continue to arise and prolong the coronavirus disease 2019 (COVID-19) pandemic. Here, we used a cell-free expression workflow to rapidly screen and optimize constructs containing multiple computationally designed miniprotein inhibitors of SARS-CoV-2. We found the broadest efficacy was achieved with a homotrimeric version of the 75-residue angiotensin-converting enzyme 2 (ACE2) mimic AHB2 (TRI2-2) designed to geometrically match the trimeric spike architecture. Consistent with the design model, in the cryo-electron microscopy structure TRI2-2 forms a tripod at the apex of the spike protein that engaged all three receptor binding domains simultaneously. TRI2-2 neutralized Omicron (B.1.1.529), Delta (B.1.617.2), and all other variants tested with greater potency than the monoclonal antibodies used clinically for the treatment of COVID-19. TRI2-2 also conferred prophylactic and therapeutic protection against SARS-CoV-2 challenge when administered intranasally in mice. Designed miniprotein receptor mimics geometrically arrayed to match pathogen receptor binding sites could be a widely applicable antiviral therapeutic strategy with advantages over antibodies in greater resistance to viral escape and antigenic drift, and advantages over native receptor traps in lower chances of autoimmune responses.


Subject(s)
COVID-19 , SARS-CoV-2 , Animals , Antibodies, Neutralizing , Antibodies, Viral , Cryoelectron Microscopy , Humans , Mice , Spike Glycoprotein, Coronavirus
15.
Sci Total Environ ; 821: 152790, 2022 May 15.
Article in English | MEDLINE | ID: mdl-35007574

ABSTRACT

Affordably tracking the transmission of respiratory infectious diseases in urban transport infrastructures can inform individuals about potential exposure to diseases and guide public policymakers to prepare timely responses based on geographical transmission in different areas in the city. Towards that end, we designed and tested a method to detect SARS-CoV-2 RNA in the air filters of public buses, revealing that air filters could be used as passive fabric sensors for the detection of viral presence. We placed and retrieved filters in the existing HVAC systems of public buses to test for the presence of trapped SARS-CoV-2 RNA using phenol-chloroform extraction and RT-qPCR. SARS-CoV-2 RNA was detected in 14% (5/37) of public bus filters tested in Seattle, Washington, from August 2020 to March 2021. These results indicate that this sensing system is feasible and that, if scaled, this method could provide a unique lens into the geographically relevant transmission of SARS-CoV-2 through public transit rider vectors, pooling samples of riders over time in a passive manner without installing any additional systems on transit vehicles.


Subject(s)
Motor Vehicles , RNA, Viral/isolation & purification , SARS-CoV-2 , Transportation , COVID-19 , Environmental Monitoring , Humans , SARS-CoV-2/isolation & purification , Washington
16.
Anal Chem ; 94(2): 1011-1021, 2022 01 18.
Article in English | MEDLINE | ID: mdl-34920665

ABSTRACT

Point-of-care diagnostics often use isothermal nucleic acid amplification for qualitative detection of pathogens in low-resource healthcare settings but lack sufficient precision for quantitative applications such as HIV viral load monitoring. Although viral load (VL) monitoring is an essential component of HIV treatment, commercially available tests rely on relatively high-resource chemistries like real-time polymerase chain reaction and are thus used on an infrequent basis for millions of people living with HIV in low-income countries. To address the constraints of low-resource settings on nucleic acid quantification, we describe a recombinase polymerase amplification and lateral flow detection approach that quantifies HIV-1 DNA or RNA by comparison to a competitive internal amplification control (IAC) of a known copy number, which may be set to any useful threshold (in our case, a clinically relevant threshold for HIV treatment failure). The IAC is designed to amplify alongside the HIV target with a similar efficiency, allowing for normalization of the assay to variation or inhibition and enabling an endpoint readout that is compatible with commercially available kits for nucleic acid lateral flow detection and interpretable with minimal instrumentation or by the naked eye. We find that this approach can reliably differentiate ≤600 or ≥1400 copies of HIV DNA from a 1000-copy threshold when lateral flow strips are imaged with a conventional office scanner and analyzed with free densitometry software. We further demonstrate a user-friendly adaptation of this analysis to process cell phone photographs with an automated script. Alternatively, we show via a survey that 21 minimally trained volunteers could reliably resolve ≥10-fold (log10) differences of HIV DNA or RNA by naked eye interpretation of lateral flow results. This amplification and detection workflow requires minimal instrumentation, takes just 30 min to complete, and when combined with a suitable sample preparation method, may enable HIV VL testing while the patient waits or a self-test, which has the potential to improve care. This approach may be adapted for other applications that require quantitative analysis of a nucleic acid target in low-resource settings.


Subject(s)
HIV Infections , Nucleic Acid Amplification Techniques , HIV Infections/diagnosis , Humans , Nucleic Acid Amplification Techniques/methods , Point-of-Care Testing , RNA, Viral/genetics , Recombinases , Viral Load
17.
PLOS Glob Public Health ; 2(2): e0000185, 2022.
Article in English | MEDLINE | ID: mdl-36962187

ABSTRACT

Usability is an overlooked aspect of implementing lab-based assays, particularly novel assays in low-resource-settings. Esoteric instructions can lead to irreproducible test results and patient harm. To address these issues, we developed a software application based on "Aquarium", a laboratory-operating system run on a computer tablet that provides step-by-step digital interactive instructions, protocol management, and sample tracking. Aquarium was paired with a near point-of-care HIV drug resistance test, "OLA-Simple", that detects mutations associated with virologic failure. In this observational study we evaluated the performance of Aquarium in guiding untrained users through the multi-step laboratory protocol with little supervision. To evaluate the training by Aquarium software we conducted a feasibility study in a laboratory at Coptic Hope Center in Nairobi, Kenya. Twelve volunteers who were unfamiliar with the kit performed the test on blinded samples (2 blood specimens; 5 codons/sample). Steps guided by Aquarium included: CD4+ T-Cell separation, PCR, ligation, detection, and interpretation of test results. Participants filled out a short survey regarding their demographics and experience with the software and kit. None of the laboratory technicians had prior experience performing CD4+ separation and 7/12 had no experience performing laboratory-based molecular assays. 12/12 isolated CD4+ T cells from whole blood with yields comparable to isolations performed by trained personnel. The OLA-Simple workflow was completed by all, with genotyping results interpreted correctly by unaided-eye in 108/120 (90%) and by software in 116/120 (97%) of codons analyzed. In the surveys, participants favorably assessed the use of software guidance. The Aquarium digital instructions enabled first-time users in Kenya to complete the OLA-simple kit workflow with minimal training. Aquarium could increase the accessibility of laboratory assays in low-resource-settings and potentially standardize implementation of clinical laboratory tests.

18.
Sci Adv ; 7(51): eabj1281, 2021 Dec 17.
Article in English | MEDLINE | ID: mdl-34910507

ABSTRACT

RNA amplification tests sensitively detect severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection, but their complexity and cost are prohibitive for expanding coronavirus disease 2019 (COVID-19) testing. We developed "Harmony COVID-19," a point-of-care test using inexpensive consumables, ready-to-use reagents, and a simple device. Our ready-to-use, multiplexed reverse transcription, loop-mediated isothermal amplification (RT-LAMP) can detect down to 0.38 SARS-CoV-2 RNA copies/µl and can report in 17 min for high­viral load samples (5000 copies/µl). Harmony detected 97 or 83% of contrived samples with ≥0.5 viral particles/µl in nasal matrix or saliva, respectively. Evaluation in clinical nasal specimens (n = 101) showed 100% detection of RNA extracted from specimens with ≥0.5 SARS-CoV-2 RNA copies/µl, with 100% specificity in specimens positive for other respiratory pathogens. Extraction-free analysis (n = 29) had 95% success in specimens with ≥1 RNA copies/µl. Usability testing performed first time by health care workers showed 95% accuracy.

19.
AIDS Res Hum Retroviruses ; 37(12): 930-935, 2021 12.
Article in English | MEDLINE | ID: mdl-34714103

ABSTRACT

The nucleoside reverse transcriptase inhibitor abacavir (ABC) is used commonly to treat young children with HIV infection and is a component of the fixed-dose-combination Triumeq®. ABC can trigger a severe hypersensitivity reaction in people who are homozygous or heterozygous for HLA-B*57:01. Testing for HLA-B*57:01 before ABC initiation is standard-of-care in high-resource settings, but current tests are costly or difficult to access in resource-limited settings. To address these gaps, we developed an inexpensive simple-to-use rapid assay to detect HLA-B*57:01. We designed and optimized a multiplexed polymerase chain reaction (PCR) to amplify HLA-B*57 subtypes and the human beta-globin gene; employed probes and ligation to specifically tag the HLA-B*57:01 allele with biotin. Tagged-ligated products were detected by immunocapture in an enzyme-linked immunosorbent assay plate or lateral flow strip. Cell lines with known HLA genotypes were used to optimize the assay. The optimized assay was then compared with genotypes of clinical specimens (n = 60) determined by sequencing, with specimens enriched for individuals with HLA-B*57:01. The optimized assay utilizes 40-min 35-cycle multiplex PCR for B*57 and beta-globin; 20-min ligation reaction; and 15-min detection. Evaluation of the HLA-B*57:01 oligonucleotide ligation assay using clinical specimens had a sensitivity of 100% (n = 27/27 typed as B*57:01) and specificity of 100% (n = 33/33 typed as non-B*57:01) by visual interpretation of lateral flow strips. The cost is US$5.96/specimen. This rapid and economical assay accurately detects HLA-B*57:01 in clinical specimens. Use of this assay could expand access to HLA-B*57:01 genotyping and facilitate safe same-day initiation of ABC-based treatment.


Subject(s)
Anti-HIV Agents , HIV Infections , Alleles , Anti-HIV Agents/adverse effects , Child, Preschool , Dideoxynucleosides/adverse effects , Genotype , HIV Infections/drug therapy , HIV Infections/genetics , HLA-B Antigens/genetics , Humans , Point-of-Care Systems
20.
medRxiv ; 2021 Aug 23.
Article in English | MEDLINE | ID: mdl-34462755

ABSTRACT

The increasing prevalence of variant lineages during the COVID-19 pandemic has the potential to disrupt molecular diagnostics due to mismatches between primers and variant templates. Point-of-care molecular diagnostics, which often lack the complete functionality of their high throughput laboratory counterparts, are particularly susceptible to this type of disruption, which can result in false negative results. To address this challenge, we have developed a robust Loop Mediated Isothermal Amplification assay with single tube multiplexed multi-target redundancy and an internal amplification control. A convenient and cost-effective target specific fluorescence detection system allows amplifications to be grouped by signal using adaptable probes for pooled reporting of SARS-COV-2 target amplifications or differentiation of the Internal Amplification Control. Over the course of the pandemic, primer coverage of viral lineages by the three redundant sub-assays has varied from assay to assay as they have diverged from the Wuhan-Hu-1 isolate sequence, but aggregate coverage has remained high for all variant sequences analyzed, with a minimum of 97.4% (Variant of Interest: Eta). In three instances (Delta, Gamma, Eta), a high frequency mismatch with one of the three sub-assays was observed, but overall coverage remained high due to multi-target redundancy. When challenged with extracted human samples the multiplexed assay showed 100% sensitivity for samples containing greater than 30 copies of viral RNA per reaction, and 100% specificity. These results are further evidence that conventional laboratory methodologies can be leveraged at the point-of-care for robust performance and diagnostic stability over time.

SELECTION OF CITATIONS
SEARCH DETAIL
...