Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Endosc Int Open ; 11(8): E785-E793, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37593156

ABSTRACT

Background and study aims Effective bowel cleansing is critical for detecting lesions during colonoscopy, highlighting the importance of bowel preparations. 1L polyethylene glycol (PEG) + ascorbate (Asc) is the only recommended 1L PEG product in Europe and the United States. Its efficacy was demonstrated in large-scale controlled trials and confirmed in smaller-scale real-world studies. However, no large-scale real-world data exist. Patients and methods This observational, retrospective, multicenter study, used outpatient follow-up data from medical records from 10 centers in Spain and two in Portugal. Outpatients aged ≥18 years using 1L PEG + Asc as bowel preparation were included. The main outcome measures were overall adequate colon cleansing (Boston Bowel Preparation Scale [BBPS] score ≥6 with BBPS score ≥2 in each segment) and high-quality cleansing of the right colon (BBPS score=3). Results Data from 13169 eligible patients were included. Overall cleansing success was achieved in 89.3% (95%CI 88.7%-89.8%) and high-quality cleansing in the right colon in 49.3% (95%CI 48.4%-50.2%) of patients. For the overnight split-dose and same-day regimens, overall adequate quality cleansing success rate was 94.7% and 86.7% ( P <0.0001) and high-quality cleansing of the right colon rate was 65.4% and 41.4% ( P <0.0001), respectively. Colonoscopy was completed in 97.3% of patients, with non-completion due to poor preparation in only 0.8%; 2.3% of patients experienced at least one adverse event (AE). Conclusions This large-scale, real-world study demonstrates the effectiveness of 1L PEG + Asc in the total and right colon, with a low percentage of patients with AEs in routine clinical practice.

2.
Endoscopy ; 52(11): 1026-1035, 2020 11.
Article in English | MEDLINE | ID: mdl-32557475

ABSTRACT

BACKGROUND: The most important predictor of unsuccessful bowel preparation is previous failure. For those patients with previous failure, we hypothesized that a nurse-led educational intervention by telephone shortly before the colonoscopy appointment could improve cleansing efficacy. METHODS: We performed a multicenter, endoscopist-blinded, randomized controlled trial. Consecutive outpatients with previous inadequate bowel preparation were enrolled. Both groups received the same standard bowel preparation protocol. The intervention group also received reinforced education by telephone within 48 hours before the colonoscopy. The primary outcome was effective bowel preparation according to the Boston Bowel Preparation Scale. Intention-to-treat (ITT) analysis included all randomized patients. Per-protocol analysis included patients who could be contacted by telephone and the control cases. RESULTS: 657 participants were recruited by 11 Spanish hospitals. In the ITT analysis, there was no significant difference between the intervention and control groups in the rate of successful bowel preparation (77.3 % vs. 72 %; P = 0.12). In the intervention group, 267 patients (82.9 %) were contacted by telephone. Per-protocol analysis revealed significantly improved bowel preparation in the intervention group (83.5 % vs. 72.0 %; P = 0.001). CONCLUSION: Among all patients with previous inadequate bowel preparation, nurse-led telephone education did not result in a significant improvement in bowel cleansing. However, in the 83 % of patients who could be contacted, bowel preparation was substantially improved. Phone education may therefore be a useful tool for improving the quality of bowel preparation in those cases.


Subject(s)
Colonoscopy , Telephone , Cathartics , Humans , Intention to Treat Analysis , Polyethylene Glycols , Prospective Studies , Single-Blind Method
SELECTION OF CITATIONS
SEARCH DETAIL
...