1.
Biomed Mater Eng ; 12(4): 353-66, 2002.
Article in English | MEDLINE | ID: mdl-12652030

ABSTRACT

Acrylic resins have been used in many different applications in dentistry, especially in the fabrication of provisional fixed partial dentures. Ideally, a provisional crown and bridge material should be easy to handle and should protect teeth against physical, chemical, and thermal injuries. Some of the problems associated with this use are related to the material's poor mechanical properties. It has been demonstrated that acrylic resin can be strengthened through the addition of structural component of different size distributed in the acrylic matrix, thus forming a composite structure. The purpose of this study was to investigate the addition effects of mixtures of titania (titanium dioxide, TiO(2)) powder and zirconia (zirconium dioxide, ZrO(2)) powder being incorporated with pre-polymerized beads mixed in monomer liquid, on some mechanical and physical properties of PMMA resin. The pre-polymerized powder poly(methyl methacrylate) resin was admixed with titania and zirconia powder. A mixing ratio was controlled by volume % of 0, 1.0, 2.0, and 3.0 (samples with 0 v/o served as control groups). For using mixture of titania and zirconia, total amount of the mixture was controlled by volume % of 1.0, 2.0, and 3.0, in which titania and zirconia were mixed at the ratio 1 :1, 1 :2 and 2 :1. Prior to mechanical tests, all rectangular-shaped samples (25 mm x 2 mm x 5 mm) were stored in 37 degrees C distilled water for 7 days after polishing all six sides of samples. Samples were then subjected to the three-point bending flexion test to evaluate the bending strength as well as the modulus of elasticity. Weight gain and exothermic reaction survey were investigated as well. All data were collected and analyzed with one-way analysis of variance (ANOVA) and Sidak method (p=0.05). It was found that the addition of particles generally decreased the water absorbed by the composite system. Only 1 percent by volume concentration of 1 :1 ratio and 2 percent by volume concentration of 1 :2 and 2 :1 ratios had significantly higher strength than control group. There was significantly higher toughness (in terms of energy-to-break) for 1 percent by volume concentration of 1 :1 ratio and 2 percent by volume concentration of 2 :1 ratio than control group. There was no significant difference between control group and all percent by volume combinations in modulus of elasticity. In addition, there was no significant variations of exothermic reaction.


Subject(s)
Composite Resins/chemistry , Denture, Partial, Temporary , Polymethyl Methacrylate/chemistry , Titanium/chemistry , Zirconium/chemistry , Absorption , Acrylic Resins/chemistry , Biocompatible Materials/chemistry , Denture Design , Denture, Partial, Fixed , Elasticity , Hardness , Hot Temperature , Materials Testing , Powders , Stress, Mechanical , Water/chemistry
2.
Biomed Mater Eng ; 8(1): 25-36, 1998.
Article in English | MEDLINE | ID: mdl-9713683

ABSTRACT

The present work investigates the corrosion behavior of 2205 duplex stainless steel in 0.9% NaCl solution after various heat-treatments, and compares it to that of 316L austenitic stainless steel. Both stainless steels were heat-treated at 500, 650, and 800 degrees C in air for 1 h, followed by furnace cooling. Each heat-treated sample was examined for their microstructures and Vickers micro-hardness, and subjected to the X-ray diffraction for the phase identification. Using potentiostatic polarization method, each heat-treated sample was corrosion-tested in 37 degrees C 0.9% NaCl solution to estimate its corrosion rate. It was found that simulated sensitization showed an adverse influence on both steels, indicating that corrosion rates increased by increasing the sensitization temperatures.


Subject(s)
Dental Alloys/chemistry , Stainless Steel/chemistry , Corrosion , Hardness Tests , Hot Temperature , Humans , Materials Testing , Orthodontic Brackets , Potentiometry , Welding , X-Ray Diffraction