Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Taiwan J Obstet Gynecol ; 61(5): 746-754, 2022 Sep.
Article in English | MEDLINE | ID: mdl-36088040

ABSTRACT

Endometrial cancer is a common malignancy in women worldwide, with myometrial invasion (MI) being an important prognostic factor, usually assessed via imaging techniques. The aim of this review is to compare the diagnostic accuracy of 3D transvaginal ultrasound (3D-TVUS), a relatively new imaging modality, to that of 2D transvaginal ultrasound (2D-TVUS) and MRI in the prediction of deep myometrial invasion. Relevant articles were sought on MEDLINE/PubMed, Scopus, Web of Science and Wiley Online Library databases. Articles were included if they were primary studies comparing 3D-TVUS to 2D-TVUS and/or MRI in adult endometrial cancer patients, with histopathological confirmation of MI as a reference standard. Ultimately, 7 studies were included, with 714 participants, 242 with deep MI and a mean age of approximately 60 years. 3D-TVUS, 2D-TVUS, MRI and 3D-TVUS-MRI co-evaluation had a pooled sensitivity of 80.4%, 77.6%, 80.7% and 94.6% respectively and a specificity range of 82.8%, 81.6%, 87% and 69.1% respectively. Overall, no statistically significant differences were found in sensitivity and specificity among 3D-TVUS and the other methods, except for a significant increase in sensitivity (p = 0.038) when combined with MRI. This shows that 3D-TVUS is comparable to MRI as far as diagnostic accuracy is concerned, however remains cheaper, less time-consuming and more tolerable, while offering some advantages over 2D-TVUS as well. Therefore 3D-TVUS application in MI assessment seems promising, although more research is required to further assess this finding and ascertain 3D-TVUS's place in endometrial cancer MI assessment.


Subject(s)
Endometrial Neoplasms , Adult , Endometrial Neoplasms/diagnostic imaging , Endometrial Neoplasms/pathology , Female , Humans , Magnetic Resonance Imaging/methods , Middle Aged , Sensitivity and Specificity , Ultrasonography/methods
2.
Int J Colorectal Dis ; 36(11): 2337-2346, 2021 Nov.
Article in English | MEDLINE | ID: mdl-34132862

ABSTRACT

PURPOSE: This study was designed to summarize the current evidence regarding the role of percutaneous tibial nerve stimulation (PTNS) in the treatment of chronic anal fissure (CAF). METHODS: The present systematic review of the literature was conducted on the basis of the PRISMA guidelines and the Cochrane Handbook for Systematic Reviews of Interventions. The primary endpoint of our study was the CAF recurrence rate. Quality assessment was based on the RoB 2 tool and the Case Series Quality Checklist. RESULTS: Overall, 5 studies and 102 patients were included. A considerably heterogeneity in the neuromodulation technique and setting was identified. The pooled recurrence rate was estimated at the level of 19% (16/84). Post-interventional pain and Wexner scores were considerably reduced. The 2-month healing rate was 72% (18/25), whereas 73.6% of patients were symptom-free at 6 months. CONCLUSIONS: PTNS is an effective alternative for the non-operative management of CAF. Due to several limitations further larger and higher quality studies are required.


Subject(s)
Fecal Incontinence , Fissure in Ano , Transcutaneous Electric Nerve Stimulation , Fissure in Ano/therapy , Humans , Quality of Life , Tibial Nerve , Treatment Outcome
3.
Nitric Oxide ; 99: 1-6, 2020 06 01.
Article in English | MEDLINE | ID: mdl-32194244

ABSTRACT

Sodium nitroprusside (SNP) is a nitric oxide (NO) donor which actually is under assessment as a potential candidate for the treatment of schizophrenia. It is well documented that anxiety symptoms are a prominent future in various psychiatric diseases comprising schizophrenia. Prior research has shown that acute challenge with SNP (1-3 mg/kg) induced anti-anxiety effects in rats but these effects at high doses were confounded by sedation and were disappeared after repeated application of it. It is still unknown if administration of a lower SNP dose range, either acutely or sub-chronically, could induce anxiolytic-like behaviour. The present study was designed to investigate this issue in rats. For this aim, the light/dark and the open field tests were used. Acute challenge with SNP (0.1 and 0.3 mg/kg, 30 min before testing) did not affect rodents' performance in the above mentioned behavioural paradigms. Conversely, rats treated sub-chronically with SNP (0.1 and 0.3 mg/kg, once per day, for 5 consecutive days), displayed longer time spent in the light chamber of the light/dark box and in the central area of the open field with respect to their vehicle-treated counterparts. Interestingly, SNP did not influence the first latency to enter the dark chamber and the number of transitions between the light and dark compartments of the apparatus in the light/dark test and did not modify the number of squares crossed, grooming episodes and rearings in the open field test. Finally, acute administration of SNP (0.1, 0.3 and 1 mg/kg, 10 min before testing) also did not influence rats' performance in the light/dark test. The present results indicate that short-term repeated but not acute application of a range of low doses of the NO donor SNP in a dose-independent manner induced an anti-anxiety behaviour in the rat which was not accompanied by undesired effects.


Subject(s)
Anti-Anxiety Agents/therapeutic use , Anxiety/drug therapy , Nitric Oxide Donors/therapeutic use , Nitroprusside/therapeutic use , Animals , Anti-Anxiety Agents/administration & dosage , Behavior, Animal/drug effects , Dose-Response Relationship, Drug , Male , Nitric Oxide Donors/administration & dosage , Nitroprusside/administration & dosage , Rats, Wistar
SELECTION OF CITATIONS
SEARCH DETAIL
...