Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
J Cardiovasc Surg (Torino) ; 65(2): 124-131, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38635285

ABSTRACT

INTRODUCTION: We performed a systematic review and meta-analysis to assess the existing published evidence regarding the safety and efficacy of the endovascular aortic repair with chimney technique (ch-EVAR) and physician-modified stent-grafts (PMSGs) for the treatment of pararenal aortic aneurysm repair. EVIDENCE ACQUISITION: A systematic search of all relevant studies reported until October 2023 according to the PRISMA (preferred reporting items for systematic reviews and meta-analyses) guidelines was performed. The pooled 30-day mortality, peri- and postoperative complication rates were estimated using fixed or random effect methods. EVIDENCE SYNTHESIS: A total of 679 study titles were identified by the initial search strategy, of which 16 were considered eligible for inclusion in the meta-analysis. A total of 1094 patients (ch-EVAR N.=861 and PMSG N.=233) (90% male) were identified. The pooled 30-day mortality rate was 3.4% for ch-EVAR and 2.6% for PMSG. The major adverse events (MAE) in the early period was 14.7% for ch-EVAR and 18.5% PMSG, respectively. Higher occlusion rate was observed of the chimney stents grafts (8.2%) than the bridging stents (1.4%) during the follow-up period. CONCLUSIONS: Ch-EVAR and physician-modified technology are safe with low 30-day mortality in elective settings for pararenal aortic aneurysms repair. No significant differences were seen between the two surgical methods regarding the early major adverse events rate. However, higher occlusion rate for the chimneys can be expected over time.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Blood Vessel Prosthesis , Endovascular Procedures , Postoperative Complications , Prosthesis Design , Stents , Humans , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Endovascular Procedures/mortality , Endovascular Procedures/methods , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/mortality , Treatment Outcome , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Abdominal/mortality , Aortic Aneurysm, Abdominal/diagnostic imaging , Postoperative Complications/etiology , Risk Factors , Male , Female , Aged , Time Factors , Risk Assessment , Middle Aged
2.
Swiss Med Wkly ; 153: 40127, 2023 11 20.
Article in English | MEDLINE | ID: mdl-37984334

ABSTRACT

BACKGROUND AND AIMS: People with familial hypercholesterolaemia are 13 times more likely to develop cardiovascular disease than the general population. However, familial hypercholesterolaemia remains largely underdiagnosed. Tendon xanthoma is a specific clinical feature of familial hypercholesterolaemia and its presence alone implies a probable diagnosis of familial hypercholesterolaemia according to the Dutch Lipid Clinic Network Score (DLCNS). The aim of the study was to determine whether ultrasound detects more Achilles tendon xanthomas (ATX) than clinical examination. METHODS: We recruited 100 consecutive patients with LDL-C ≥4 mmol/l. Achilles tendons were evaluated through clinical examination by trained physicians and sonographic examination by another physician blind to the results of clinical examination. Blind second readings of ultrasound images were performed by an expert in musculoskeletal ultrasound. We compared the proportion of patients with ATX detected by either clinical examination or ultrasound and the proportion of patients with a probable/definite familial hypercholesterolaemia diagnosis on the DLCNS before and after ultrasound. RESULTS: Mean (SD) age was 47 (12) years; mean highest LDL-C was 6.57 mmol/l (2.2). ATX were detected in 23% of patients by clinical examination and in 60% by ultrasound. In consequence, 43% had a probable/definite diagnosis of familial hypercholesterolaemia on the DLCNS using clinical examination compared with 72% when ultrasound was used. CONCLUSION: Compared to clinical examination, ultrasound examination of the Achilles tendon substantially improves the detection of ATX and may help to better identify patients with familial hypercholesterolaemia who are at high risk for premature cardiovascular disease.


Subject(s)
Achilles Tendon , Cardiovascular Diseases , Hyperlipoproteinemia Type II , Humans , Middle Aged , Achilles Tendon/diagnostic imaging , Cholesterol, LDL , Cross-Sectional Studies , Hyperlipoproteinemia Type II/diagnostic imaging , Ultrasonography
3.
J Clin Med ; 12(14)2023 Jul 15.
Article in English | MEDLINE | ID: mdl-37510822

ABSTRACT

BACKGROUND: There is a paucity of reporting outcomes of complex aortic aneurysm treatment such as juxtarenal abdominal aortic aneurysms, where additional techniques to preserve renal artery perfusion are required. METHODS: Retrospective analysis of consecutive patients who underwent emergent and elective aortic repair with fenestrated PMEGs between March 2019 and January 2023. Endpoints were technical success, reinterventions, secondary reinterventions and target vessel patency. RESULTS: Forty-seven target vessels in 37 patients (23 male, median age 75 years) were targeted, of which 44 were renal arteries (RAs) with a mean diameter of 5.4 ± 1.0 mm. Thirteen were accessory RAs and six had a diameter ≤ 4 mm. Technical success rate was 87% overall; 97% for main and 62% for accessory RAs respectively. Target vessel patency and freedom from secondary reintervention was 100% and 97% at 30 days and 96% and 91% at one year, respectively. There was no 30-day mortality. CONCLUSION: Fenestrated physician-modified endografts are safe and effective for the treatment of patients with juxtarenal abdominal aortic aneurysms when incorporating main renal arteries. Limited technical success may be expected when targeting accessory renal arteries, especially when small in diameter. Long-term follow-up is needed to confirm durability of PMEGs for renal artery preservation.

4.
J Endovasc Ther ; : 15266028231173311, 2023 May 16.
Article in English | MEDLINE | ID: mdl-37191262

ABSTRACT

PURPOSE: We describe the feasibility and early results of a novel endovascular approach with a surgeon-modified fenestrated iliac stent graft to preserve pelvic perfusion in patients with iliac aneurysms not suitable for iliac branch devices (IBDs). TECHNIQUE: Seven high-risk patients, median age 76 years (range 63-83), with a complex aortoiliac anatomy with contraindications for commercially available IBDs were treated with a novel surgeon-modified fenestrated iliac stent graft between August 2020 and November 2021. The modified device was built using an iliac limb stent graft (Endurant II Stent Graft; Medtronic), which was partially deployed, surgically fenestrated with a scalpel, reinforced, re-sheathed, and inserted via femoral access. The internal iliac artery was cannulated and bridged with a covered stent. Technical success rate was 100%. After a median follow-up period of 10 months, there was 1 type II endoleak and no migrations, stent fractures, or loss of device integrity. One iliac limb occlusion occurred after 7 months, which needed a secondary endovascular intervention, restoring patency. CONCLUSION: Surgeon-modified fenestrated iliac stent graft is feasible and might be used as an alternative in patients with a complex iliac anatomy not suitable to commercially available IBDs. Long-term follow-up is needed to evaluate stent graft patency and potential complications. CLINICAL IMPACT: Surgeon modified fenetrated iliac stent grafts might be a promising alternative to iliac branch devices, extending endovascular solutions to a broader patient population with complex aorto-iliac anatomies preserving antegrade internal iliac artery perfusion. It is possible to treat small iliac bifurcations and large angulations of the iliac bifurcation safely and there is no need for a contralateral or upper-extremity access.

SELECTION OF CITATIONS
SEARCH DETAIL
...