Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Sci Rep ; 8(1): 4735, 2018 03 16.
Article in English | MEDLINE | ID: mdl-29549265

ABSTRACT

Absolute measurements of the radiolytic yield of Fe3+ in a ferrous sulphate dosimeter formulation (6 mM Fe2+), with a 20 keV x-ray monoenergetic beam, are reported. Dose-rate suppression of the radiolytic yield was observed at dose rates lower than and different in nature to those previously reported with x-rays. We present evidence that this effect is most likely to be due to recombination of free radicals radiolytically produced from water. The method used to make these measurements is also new and it provides radiolytic yields which are directly traceable to the SI standards system. The data presented provides new and exacting tests of radiation chemistry codes.

2.
J Trace Elem Med Biol ; 47: 79-88, 2018 May.
Article in English | MEDLINE | ID: mdl-29544811

ABSTRACT

In the present study, several Cu chelators [2,2'-biquinoline, 8-hydroxiquinoline (oxine), ammonium pyrrolidinedithiocarbamate (APDTC), Dp44mT, dithizone, neocuproine] were used to study Cu uptake, depletion and localization in different cancer cell lines. To better understand the concentration dependent fluctuations in the Cu intracellular metal content and Cu-dependent in vitro antiproliferative data, the conditional stability constants of the Cu complex species of the investigated ligands were calculated. Each investigated chelator increased the intracellular Cu content on HT-29 cells causing Cu accumulation depending on the amount of the free Cu(II). Copper accumulation was 159 times higher for Dp44mT compared to the control. Investigating a number of other transition metals, intracellular accumulation of Cd was observed only for two chelators. Intracellular Zn content slightly decreased (cca. 10%) for MCF-7 cells, while a dramatic decrease was observed on MDA-MB-231 ones (cca. 50%). A similar decrease was observed for HCT-116, while Zn depletion for HT-29 corresponded to cca. 20%. The IC50 values were registered for the investigated four cell lines at increasing external Cu(II) concentration, namely, MDA-MB-231 cells had the lowest IC50 values for Dp44mT ranging between 7 and 35 nM. Thus, Zn depletion could be associated with lower IC50 values. Copper depletion was observed for all ligands being less pronounced for Dp44mT and neocuproine. Copper localization and its colocalization with Zn were determined by µ-XRF imaging. Loose correlation (0.57) was observed for the MCF-7 cells independently of the applied chelator. Similarly, a weak correlation (0.47) was observed for HT-29 cells treated with Cu(II) and oxine. Colocalization of Cu and Zn in the nucleus of HT-29 cells was observed for Dp44mT (correlation coefficient of 0.85).


Subject(s)
Chelating Agents/pharmacology , Copper/metabolism , Antineoplastic Agents/pharmacology , Cell Line, Tumor , Copper/pharmacokinetics , Copper/toxicity , Dithizone/pharmacology , Humans , Metals/pharmacokinetics , Oxyquinoline/pharmacology , Phenanthrolines/pharmacology , Thiosemicarbazones/pharmacology , Zinc/metabolism , Zinc/pharmacokinetics
3.
Opt Lett ; 38(6): 827-9, 2013 Mar 15.
Article in English | MEDLINE | ID: mdl-23503229

ABSTRACT

The x-ray wavefront downstream of a Fresnel zone plate (FZP) was characterized using a two-dimensional grating interferometer. Transverse wavefront slope maps, measured using a raster phase-stepping scan, allowed accurate phase reconstruction of the x-ray beam. Wavefront measurements revealed that the wavefront error is very sensitive to the input beam entering the FZP. A small stack of one-dimensional compound refractive lenses was used to introduce astigmatism in the probing x-ray beam to investigate the contribution of the incoming beam in contrast to the optical aberrations. Experimental data were shown to be consistent with theoretical calculations.

SELECTION OF CITATIONS
SEARCH DETAIL
...