Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add more filters










Database
Language
Publication year range
1.
Sci Rep ; 9(1): 16435, 2019 Nov 11.
Article in English | MEDLINE | ID: mdl-31712643

ABSTRACT

We investigate the damage resistance of saturated and unsaturated liquid crystals (LC's) under a wide range of laser excitation conditions, including 1053-nm pulse durations between 600 fs and 1.5 ns and nanosecond pulse excitation at 351 nm and 532 nm. This study explores the relationship between the LC's resistance to laser-induced breakdown (damage) and the electronic structure (π-electron delocalization) of the constituent molecules. The laser-induced damage threshold at all wavelengths and pulse durations was consistently higher in saturated materials than in their unsaturated counterparts. The wavelength's dependence in the results suggests that the energy coupling process that leads to laser-induced breakdown is governed by the energy separation between the ground state and the first and second excited states, while the pulse duration's dependence in the results reveals the important role of electron relaxation between the excited states. A qualitative description was developed to interpret the experimental observations.

2.
Opt Express ; 27(12): 16922-16934, 2019 Jun 10.
Article in English | MEDLINE | ID: mdl-31252910

ABSTRACT

Owing to their relatively high resistance to laser-induced damage, hafnia and silica are commonly used in multilayered optical coatings in high-power laser facilities as high- and low-refractive-index materials, respectively. Here, we quantify the laser-induced-damage threshold (LIDT) at 1053 nm in the short-pulse regime of hafnia and silica monolayers deposited by different fabrication methods, including electron-beam evaporation, plasma ion-assisted deposition and ion-assisted deposition. The results demonstrate that nominally identical coatings fabricated by different deposition techniques and/or vendors can exhibit significantly different damage thresholds. A correlation of the LIDT performance of each material with its corresponding absorption edge is investigated. Our analysis indicates a weak correlation between intrinsic LIDT and the optical gap of each material (Tauc gap) but a much better correlation when considering the spectral characteristics in the Urbach tail spectral range. Spectrophotometry and photothermal absorption were used to provide evidence of the correlation between the strength of the red-shifted absorption tail and reduced LIDT at 1053 nm.

3.
Appl Opt ; 58(14): 3908-3912, 2019 May 10.
Article in English | MEDLINE | ID: mdl-31158208

ABSTRACT

A spectroscopic setup that enables the mapping of absorption and photoluminescence with submicrometer spatial resolution and high sensitivity is described. A photothermal heterodyne imaging pump/probe technique is employed for absorption mapping, and low-signal, spatially resolved photoluminescence is recorded using photon counting. High-spatial-resolution mapping is accomplished by using high-numerical-aperture microscope objective focusing laser beams (pump and probe) into a submicrometer spot and raster-scanning sample mounted on the nanopositioning translation stage. Performance of the setup is illustrated by mapping absorption and luminescence of the hafnium oxide film with embedded hafnium nanoparticles and multilayer dielectric grating. In both cases, submicrometer spatial resolution is demonstrated, and possible physical mechanisms leading to image contrast on a submicrometer scale are discussed.

4.
Opt Express ; 26(13): 17608-17623, 2018 Jun 25.
Article in English | MEDLINE | ID: mdl-30119572

ABSTRACT

Hafnium oxide thin films with varying oxygen content were investigated with the goal of finding the optical signature of oxygen vacancies in the film structure. It was found that a reduction of oxygen content in the film leads to changes in both, structural and optical characteristics. Optical absorption spectroscopy, using nanoKelvin calorimetry, revealed an enhanced absorption in the near-ultraviolet (near-UV) and visible wavelength ranges for films with reduced oxygen content, which was attributed to mid-gap electronic states of oxygen vacancies. Absorption in the near-infrared was found to originate from structural defects other than oxygen vacancy. Luminescence generated by continuous-wave 355-nm laser excitation in e-beam films showed significant changes in the spectral profile with oxygen reduction and new band formation linked to oxygen vacancies. The luminescence from oxygen-vacancy states was found to have microsecond-scale lifetimes when compared with nanosecond-scale lifetimes of luminescence attributed to other structural film defects. Laser-damage testing using ultraviolet nanosecond and infrared femtosecond pulses showed a reduction of the damage threshold with increasing number of oxygen vacancies in hafnium oxide films.

5.
Opt Lett ; 43(6): 1239-1242, 2018 Mar 15.
Article in English | MEDLINE | ID: mdl-29543261

ABSTRACT

Laser conditioning was investigated as a function of the temporal shape and duration of 351 nm nanosecond pulses for fused-silica substrates polished via magnetorheological finishing. The aim is to advance our understanding of the dynamics involved to enable improved control of the interaction of laser light with the material to optimize laser conditioning. Gaussian pulses that are temporally truncated at the intensity peak are observed to enhance laser conditioning, in comparison to a Gaussian pulse shape.

6.
Appl Opt ; 56(9): 2494-2503, 2017 Mar 20.
Article in English | MEDLINE | ID: mdl-28375358

ABSTRACT

We demonstrate how a nanomechanical test identifies areas of mechanical field concentration as being comparable to areas where optical fields are known to be concentrated, in the special context of laser-induced damage testing (LIDT) of diffractive gratings of silica deposited on optical multilayers. The nano-indentation response of the diffraction gratings is measured in a new mode that allows for the extraction of a measurable metric characterizing the brittleness of the gratings, as well as their ductility. We show that lower LIDTs are positively correlated with an increased grating brittleness, and therefore identify a nanomechanical approach to describe LIDTs. We present extensive numerical simulations of nano-indentation tests and identify different deformation modes including stretching, shear concentration, and bending as precursors to mechanical failure in the nano-indentation test. The effects of geometrical inhomogeneities on enhanced stress generation in these gratings are specifically examined and addressed, and we show the agreement between nanomechanical testing and analytical interpretation of these inhomogeneities.

7.
Opt Lett ; 24(8): 516-8, 1999 Apr 15.
Article in English | MEDLINE | ID: mdl-18071557

ABSTRACT

The 351-nm laser-damage initiation threshold for surface damage in conventionally polished fused silica is demonstrated to be stress dependent. By circumferential application of modest loads to a sample, a controllable stress field can be established within the clear aperture of a fused-silica specimen, in response to which both the damage-initiation fluence and the crack-propagation fluence requirements are increased above those for unstressed conditions.

8.
Appl Opt ; 38(33): 6892-903, 1999 Nov 20.
Article in English | MEDLINE | ID: mdl-18324232

ABSTRACT

Results of experiments on stress-inhibited laser-driven crack growth and stress-delayed laser-damage initiation thresholds in fused silica, borosilicate glass (BK-7), and cleaved bulk silica are presented. A numerical model is developed to explain the crack arrest in fused silica. Good agreement is obtained between the model and a finite-element code. The crack arrest is demonstrated to be the result of the breaking of a hoop-stress symmetry that is responsible for crack propagation in fused silica.

9.
J Cataract Refract Surg ; 23(10): 1561-71, 1997 Dec.
Article in English | MEDLINE | ID: mdl-9456417

ABSTRACT

PURPOSE: To determine the ability and threshold energy of the neodymium:yttrium-lithium-fluoride (Nd:YLF) picosecond laser to achieve micron-level polishing of a latex posterior capsule facsimile (PCF) as an alternative to laser capsulotomy to treat posterior capsule opacification. SETTING: University of Rochester Medical Center, Rochester, New York, USA. METHODS: A solid-state, mode-locked Nd:YLF picosecond laser was used to polish a latex PCF in contact with a poly(methyl methacrylate) intraocular lens (IOL) in an experimental model eye. Eight study groups were treated at different energy levels ranging from 5 to 15 microJ. All treatments were done at least three times in different latex capsules and lenses. An atomic force microscope was used to measure IOL damage and an interferometric surface analysis microscope to assess the polishing effect on the PCF. The IOLs were further subjected to a scatter analysis to assess the optical significance of the damage produced. RESULTS: The latex PCF revealed a polishing effect with all energy settings used. The IOLs were damaged with all energy settings but 5 microJ. Energy settings higher than 5 microJ caused significantly more polishing effect to the latex and damage to the lenses. At the 10 microJ energy level, a single parameter with no depth produced a relative polishing depth of 3.01 microns +/- 0.10 (root mean square +/- SD). At this energy, the damage to the IOLs was 188 +/- 20.52 nm, and it was associated with typical craters over the surface at regular intervals that corresponded to each individual laser pulse. CONCLUSION: This model documented the feasibility of achieving micron-level precision in excising material with the picosecond laser and showed that posterior capsule polishing should be feasible and safe in human eyes.


Subject(s)
Laser Therapy , Lens Capsule, Crystalline/surgery , Lenses, Intraocular , Models, Anatomic , Postoperative Complications/surgery , Humans , Laser Therapy/adverse effects , Laser Therapy/methods , Lens Capsule, Crystalline/pathology , Microscopy, Atomic Force , Polymethyl Methacrylate , Postoperative Complications/pathology
SELECTION OF CITATIONS
SEARCH DETAIL
...