Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Language
Publication year range
1.
Eur Radiol Exp ; 8(1): 57, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38724831

ABSTRACT

BACKGROUND: We compared computed tomography (CT) images and holograms (HG) to assess the number of arteries of the lung lobes undergoing lobectomy and assessed easiness in interpretation by radiologists and thoracic surgeons with both techniques. METHODS: Patients scheduled for lobectomy for lung cancer were prospectively included and underwent CT for staging. A patient-specific three-dimensional model was generated and visualized in an augmented reality setting. One radiologist and one thoracic surgeon evaluated CT images and holograms to count lobar arteries, having as reference standard the number of arteries recorded at surgery. The easiness of vessel identification was graded according to a Likert scale. Wilcoxon signed-rank test and κ statistics were used. RESULTS: Fifty-two patients were prospectively included. The two doctors detected the same number of arteries in 44/52 images (85%) and in 51/52 holograms (98%). The mean difference between the number of artery branches detected by surgery and CT images was 0.31 ± 0.98, whereas it was 0.09 ± 0.37 between surgery and HGs (p = 0.433). In particular, the mean difference in the number of arteries detected in the upper lobes was 0.67 ± 1.08 between surgery and CT images and 0.17 ± 0.46 between surgery and holograms (p = 0.029). Both radiologist and surgeon showed a higher agreement for holograms (κ = 0.99) than for CT (κ = 0.81) and found holograms easier to evaluate than CTs (p < 0.001). CONCLUSIONS: Augmented reality by holograms is an effective tool for preoperative vascular anatomy assessment of lungs, especially when evaluating the upper lobes, more prone to anatomical variations. TRIAL REGISTRATION: ClinicalTrials.gov, NCT04227444 RELEVANCE STATEMENT: Preoperative evaluation of the lung lobe arteries through augmented reality may help the thoracic surgeons to carefully plan a lobectomy, thus contributing to optimize patients' outcomes. KEY POINTS: • Preoperative assessment of the lung arteries may help surgical planning. • Lung artery detection by augmented reality was more accurate than that by CT images, particularly for the upper lobes. • The assessment of the lung arterial vessels was easier by using holograms than CT images.


Subject(s)
Augmented Reality , Holography , Lung Neoplasms , Pulmonary Artery , Tomography, X-Ray Computed , Humans , Female , Male , Tomography, X-Ray Computed/methods , Aged , Prospective Studies , Lung Neoplasms/surgery , Lung Neoplasms/diagnostic imaging , Middle Aged , Holography/methods , Pulmonary Artery/diagnostic imaging , Pulmonary Artery/anatomy & histology , Imaging, Three-Dimensional , Reference Standards , Lung/diagnostic imaging , Lung/blood supply , Lung/surgery
2.
J Thorac Cardiovasc Surg ; 165(4): 1418-1429.e4, 2023 04.
Article in English | MEDLINE | ID: mdl-33781593

ABSTRACT

OBJECTIVE: The study objective was to elucidate the mechanisms of left ventricle functional recovery in terms of endocardial contractility and synchronicity after surgical ventricular reconstruction. METHODS: Real-time 3-dimensional transthoracic echocardiography was performed on 20 patients with anterior left ventricle remodeling and ischemic heart failure before surgical ventricular reconstruction and at 6-month follow-up, and on 15 healthy controls matched by age and body surface area. Real-time 3-dimensional transthoracic echocardiography datasets were analyzed through TomTec software (4D LV-Analysis; TomTec Imaging Systems GmbH, Unterschleissheim, Germany): Left ventricle volumes, ejection fraction, and global longitudinal strain were computed; the time-dependent endocardial surface yielded by 3-dimensional speckle-tracking echocardiography was postprocessed through in-house software to quantify local systolic minimum principal strain as a measure of fiber shortening and mechanical dispersion as a measure of fiber synchronicity. RESULTS: Compared with controls, patients with heart failure before surgical ventricular reconstruction showed lower ejection fraction (P < .0001) and significantly impaired mechanical dispersion (P < .0001) and minimum principal strain (P < .0001); the latter worsened progressively from left ventricle base to apex. After surgical ventricular reconstruction, global longitudinal strain improved from -6.7% to -11.3% (P < .0001); mechanical dispersion decreased in every left ventricle region (P ≤ .017) and mostly in the basal region, where computed mechanical dispersion values were comparable to physiologic values (P ≥ .046); minimum principal strain improved mostly in the basal region, changing from -16.6% to -22.3% (P = .0027). CONCLUSIONS: At 6-month follow-up, surgical ventricular reconstruction was associated with significant recovery in global left ventricle function, improved mechanical dispersion indicating a more synchronous left ventricle contraction, and improved left ventricle fiber shortening mostly in the basal region, suggesting the major role of the remote myocardium in enhancing left ventricle functional recovery.


Subject(s)
Echocardiography, Three-Dimensional , Heart Failure , Ventricular Dysfunction, Left , Humans , Ventricular Function, Left/physiology , Echocardiography/methods , Echocardiography, Three-Dimensional/methods , Heart Failure/diagnostic imaging , Heart Failure/surgery , Heart Ventricles/diagnostic imaging , Heart Ventricles/surgery , Stroke Volume/physiology , Reproducibility of Results
3.
J Cardiovasc Comput Tomogr ; 14(6): 520-523, 2020.
Article in English | MEDLINE | ID: mdl-32409264

ABSTRACT

Multidetector computed tomography (MDCT) is currently the imaging technique of choice for the assessment of tricuspid valve (TV) annulus geometry and relationship with the right coronary artery (RCA). However, standardized protocols with a full 3D analysis are still lacking to plan percutaneous procedures for functional tricuspid regurgitation (FTR). A novel customized 4-dimensional tool based on MDCT data was developed and provided accurate information on TV annulus morphology (3D-perimeter, 2D-Area, maximum and minimum diameters, eccentricity index), function and distance to the RCA, crucial for patient selection of percutaneous TV procedures.


Subject(s)
Computed Tomography Angiography , Coronary Angiography , Coronary Vessels/diagnostic imaging , Four-Dimensional Computed Tomography , Multidetector Computed Tomography , Software , Tricuspid Valve Insufficiency/diagnostic imaging , Tricuspid Valve/diagnostic imaging , Aged , Aged, 80 and over , Clinical Decision-Making , Female , Humans , Male , Predictive Value of Tests , Radiographic Image Interpretation, Computer-Assisted , Tricuspid Valve/surgery , Tricuspid Valve Insufficiency/surgery
4.
Eur J Cardiothorac Surg ; 55(Suppl 1): i49-i56, 2019 06 01.
Article in English | MEDLINE | ID: mdl-31106339

ABSTRACT

An increase in left ventricular volume after a myocardial infarction is a key component of the adverse remodelling process leading to chamber dysfunction, heart failure and an unfavourable outcome. Hence, the therapeutic strategies have been designed to reverse the remodelling process by medical therapy, devices or surgical strategies. Surgical ventricular reconstruction primarily combined with myocardial revascularization has been introduced as an optional intervention aimed to reduce the left ventricle through resection of the scar tissue and is recommended in selected patients with predominant heart failure symptoms, and with myocardial scarring and moderate left ventricular remodelling. This review outlines the rationale and the technique for reconstructing the left ventricle and the possible indications for using that technique, based on experiences from the centre with the largest international experience. The major contributions in the literature are briefly discussed.


Subject(s)
Cardiomyopathies/surgery , Heart Ventricles/surgery , Myocardial Ischemia/surgery , Ventricular Remodeling , Biomarkers/blood , Contraindications, Procedure , Humans , Mitral Valve/surgery , Mitral Valve Insufficiency/surgery , Natriuretic Peptide, Brain/blood , Patient Selection , Peptide Fragments/blood
5.
APL Bioeng ; 2(4): 046102, 2018 Dec.
Article in English | MEDLINE | ID: mdl-31069324

ABSTRACT

Organs-on-chip technology has recently emerged as a promising tool to generate advanced cardiac tissue in vitro models, by recapitulating key physiological cues of the native myocardium. Biochemical, mechanical, and electrical stimuli have been investigated and demonstrated to enhance the maturation of cardiac constructs. However, the combined application of such stimulations on 3D organized constructs within a microfluidic platform was not yet achieved. For this purpose, we developed an innovative microbioreactor designed to provide a uniform electric field and cyclic uniaxial strains to 3D cardiac microtissues, recapitulating the complex electro-mechanical environment of the heart. The platform encompasses a compartment to confine and culture cell-laden hydrogels, a pressure-actuated chamber to apply a cyclic uniaxial stretch to microtissues, and stainless-steel electrodes to accurately regulate the electric field. The platform was exploited to investigate the effect of two different electrical stimulation patterns on cardiac microtissues from neonatal rat cardiomyocytes: a controlled electric field [5 V/cm, or low voltage (LV)] and a controlled current density [74.4 mA/cm2, or high voltage (HV)]. Our results demonstrated that LV stimulation enhanced the beating properties of the microtissues. By fully exploiting the platform, we combined the LV electrical stimulation with a physiologic mechanical stretch (10% strain) to recapitulate the key cues of the native cardiac microenvironment. The proposed microbioreactor represents an innovative tool to culture improved miniaturized cardiac tissue models for basic research studies on heart physiopathology and for drug screening.

6.
J Thorac Dis ; 9(Suppl 4): S225-S238, 2017 Apr.
Article in English | MEDLINE | ID: mdl-28540065

ABSTRACT

BACKGROUND: Accurate quantification of mitral valve (MV) morphology and dynamic behavior over the cardiac cycle is crucial to understand the mechanisms of degenerative MV dysfunction and to guide the surgical intervention. Cardiac magnetic resonance (CMR) imaging has progressively been adopted to evaluate MV pathophysiology, although a dedicated framework is required to perform a quantitative assessment of the functional MV anatomy. METHODS: We investigated MV dynamic behavior in subjects with normal MV anatomy (n=10) and patients referred to surgery due to degenerative MV prolapse, classified as fibro-elastic deficiency (FED, n=9) and Barlow's disease (BD, n=10). A CMR-dedicated framework was adopted to evaluate prolapse height and volume and quantitatively assess valvular morphology and papillary muscles (PAPs) function over the cardiac cycle. Multiple comparison was used to investigate the hallmarks associated to MV degenerative prolapse and evaluate the feasibility of anatomical and functional distinction between FED and BD phenotypes. RESULTS: On average, annular dimensions were significantly (P<0.05) larger in BD than in FED and normal subjects while no significant differences were noticed between FED and normal. MV eccentricity progressively decreased passing from normal to FED and BD, with the latter exhibiting a rounder annulus shape. Over the cardiac cycle, we noticed significant differences for BD during systole with an abnormal annular enlargement between mid and late systole (LS) (P<0.001 vs. normal); the PAPs dynamics remained comparable in the three groups. Prolapse height and volume highlighted significant differences among normal, FED and BD valves. CONCLUSIONS: Our CMR-dedicated framework allows for the quantitative and dynamic evaluation of MV apparatus, with quantifiable annular alterations representing the primary hallmark of severe MV degeneration. This may aid surgeons in the evaluation of the severity of MV dysfunction and the selection of the appropriate MV treatment.

7.
J Biomech ; 50: 83-92, 2017 01 04.
Article in English | MEDLINE | ID: mdl-27863743

ABSTRACT

Mitraclip® implantation is widely used as a valid alternative to conventional open-chest surgery in high-risk patients with severe mitral valve (MV) regurgitation. Although effective in reducing mitral regurgitation (MR) in the majority of cases, the clip implantation produces a double-orifice area that can result in altered MV biomechanics, particularly in term of hemodynamics and mechanical stress distribution on the leaflets. In this scenario, we combined the consistency of in vitro experimental platforms with the versatility of numerical simulations to investigate clip impact on MV functioning. The fluid dynamic determinants of the procedure were experimentally investigated under different working conditions (from 40bpm to 100bpm of simulated heart rate) on six swine hearts; subsequently, fluid dynamic data served as realistic boundary conditions in a computational framework able to quantitatively assess the post-procedural MV biomechanics. The finite element model of a human mitral valve featuring an isolated posterior leaflet prolapse was reconstructed from cardiac magnetic resonance. A complete as well as a marginal, sub-optimal grasping of the leaflets were finally simulated. The clipping procedure resulted in a properly coapting valve from the geometrical perspective in all the simulated configurations. Symmetrical complete grasping resulted in symmetrical distribution of the mechanical stress, while uncomplete asymmetrical grasping resulted in higher stress distribution, particularly on the prolapsing leaflet. This work pinpointed that the mechanical stress distribution following the clipping procedure is dependent on the cardiac hemodynamics and has a correlation with the proper execution of the grasping procedure, requiring accurate evaluation prior to clip delivery.


Subject(s)
Mitral Valve Prolapse/physiopathology , Mitral Valve/physiopathology , Animals , Cardiac Output , Computer Simulation , Finite Element Analysis , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation/methods , Humans , Male , Middle Aged , Mitral Valve/surgery , Mitral Valve Insufficiency/physiopathology , Mitral Valve Prolapse/diagnostic imaging , Mitral Valve Prolapse/surgery , Models, Cardiovascular , Sus scrofa
8.
J Thorac Cardiovasc Surg ; 150(5): 1303-12.e4, 2015 Nov.
Article in English | MEDLINE | ID: mdl-26277475

ABSTRACT

OBJECTIVES: Intraoperative assessment of the proper neochordal length during mitral plasty may be complex sometimes. Patient-specific finite element models were used to elucidate the biomechanical drawbacks underlying an apparently correct mitral repair for isolated posterior prolapse. METHODS: Preoperative patient-specific models were derived from cardiac magnetic resonance images; integrated with intraoperative surgical details to assess the location and extent of the prolapsing region, including the number and type of diseased chordae; and complemented by the biomechanical properties of mitral leaflets, chordae tendineae, and artificial neochordae. We investigated postoperative mitral valve biomechanics in a wide spectrum of different techniques (single neochorda, double neochordae, and preconfigured neochordal loop), all reestablishing adequate valvular competence, but differing in suboptimal millimetric expanded polytetrafluoroethylene suture lengths in a range of ±2 mm, compared with the corresponding "ideal repair." RESULTS: Despite the absence of residual regurgitation, alterations in chordal forces and leaflet stresses arose simulating suboptimal repairs; alterations were increasingly relevant as more complex prolapse anatomies were considered and were worst when simulating single neochorda implantation. Multiple chordae implantations were less sensitive to errors in neochordal length tuning, but associated postoperative biomechanics were hampered when asymmetric configurations were reproduced. Computational outcomes were consistent with the presence and entity of recurrent mitral regurgitation at midterm follow-up of simulated patients. CONCLUSIONS: Suboptimal suture length tuning significantly alters chordal forces and leaflet stresses, which may be key parameters in determining the long-term outcome of the repair. The comparison of the different simulated techniques suggests possible criteria for the selection and implementation of neochordae implantation techniques.


Subject(s)
Chordae Tendineae/transplantation , Heart Valve Prosthesis Implantation/adverse effects , Mitral Valve Annuloplasty/adverse effects , Mitral Valve Insufficiency/surgery , Mitral Valve Prolapse/surgery , Mitral Valve/transplantation , Biomechanical Phenomena , Chordae Tendineae/pathology , Chordae Tendineae/physiopathology , Computer Simulation , Finite Element Analysis , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/methods , Humans , Magnetic Resonance Imaging , Mitral Valve/pathology , Mitral Valve/physiopathology , Mitral Valve Annuloplasty/instrumentation , Mitral Valve Annuloplasty/methods , Mitral Valve Insufficiency/diagnosis , Mitral Valve Insufficiency/physiopathology , Mitral Valve Prolapse/diagnosis , Mitral Valve Prolapse/physiopathology , Models, Cardiovascular , Polytetrafluoroethylene , Predictive Value of Tests , Prosthesis Design , Recurrence , Risk Factors , Suture Techniques , Sutures , Treatment Failure
SELECTION OF CITATIONS
SEARCH DETAIL
...