Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
1.
Int J Radiat Oncol Biol Phys ; 119(5): 1429-1436, 2024 Aug 01.
Article in English | MEDLINE | ID: mdl-38432285

ABSTRACT

PURPOSE: The capacity for machine learning (ML) to facilitate radiation therapy (RT) planning for primary brain tumors has not been described. We evaluated ML-assisted RT planning with regard to clinical acceptability, dosimetric outcomes, and planning efficiency for adults and children with primary brain tumors. METHODS AND MATERIALS: In this prospective study, children and adults receiving 54 Gy fractionated RT for a primary brain tumor were enrolled. For each patient, one ML-assisted RT plan was created and compared with 1 or 2 plans created using standard ("manual") planning procedures. Plans were evaluated by the treating oncologist, who was blinded to the method of plan creation. The primary endpoint was the proportion of ML plans that were clinically acceptable for treatment. Secondary endpoints included the frequency with which ML plans were selected as preferable for treatment, and dosimetric differences between ML and manual plans. RESULTS: A total of 116 manual plans and 61 ML plans were evaluated across 61 patients. Ninety-four percent of ML plans and 93% of manual plans were judged to be clinically acceptable (P = 1.0). Overall, the quality of ML plans was similar to manual plans. ML plans comprised 34.5% of all plans evaluated and were selected for treatment in 36.1% of cases (P = .82). Similar tumor target coverage was achieved between both planning methods. Normal brain (brain minus planning target volume) received an average of 1 Gy less mean dose with ML plans (compared with manual plans, P < .001). ML plans required an average of 45.8 minutes less time to create, compared with manual plans (P < .001). CONCLUSIONS: ML-assisted automated planning creates high-quality plans for patients with brain tumors, including children. Plans created with ML assistance delivered slightly less dose to normal brain tissues and can be designed in less time.


Subject(s)
Brain Neoplasms , Machine Learning , Radiotherapy Planning, Computer-Assisted , Humans , Brain Neoplasms/radiotherapy , Brain Neoplasms/diagnostic imaging , Radiotherapy Planning, Computer-Assisted/methods , Prospective Studies , Child , Adult , Male , Female , Adolescent , Organs at Risk/radiation effects , Young Adult , Middle Aged , Child, Preschool , Radiotherapy Dosage , Aged , Dose Fractionation, Radiation
2.
Clin Transl Radiat Oncol ; 42: 100663, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37587925

ABSTRACT

Background and purpose: Brain radiotherapy (cnsRT) requires reproducible positioning and immobilization, attained through redundant dedicated imaging studies and a bespoke moulding session to create a thermoplastic mask (T-mask). Innovative approaches may improve the value of care. We prospectively deployed and assessed the performance of a patient-specific 3D-printed mask (3Dp-mask), generated solely from MR imaging, to replicate a reproducible positioning and tolerable immobilization for patients undergoing cnsRT. Material and methods: Patients undergoing LINAC-based cnsRT (primary tumors or resected metastases) were enrolled into two arms: control (T-mask) and investigational (3Dp-mask). For the latter, an in-house designed 3Dp-mask was generated from MR images to recreate the head positioning during MR acquisition and allow coupling with the LINAC tabletop. Differences in inter-fraction motion were compared between both arms. Tolerability was assessed using patient-reported questionnaires at various time points. Results: Between January 2020 - July 2022, forty patients were enrolled (20 per arm). All participants completed the prescribed cnsRT and study evaluations. Average 3Dp-mask design and printing completion time was 36 h:50 min (range 12 h:56 min - 42 h:01 min). Inter-fraction motion analyses showed three-axis displacements comparable to the acceptable tolerance for the current standard-of-care. No differences in patient-reported tolerability were seen at baseline. During the last week of cnsRT, 3Dp-mask resulted in significantly lower facial and cervical discomfort and patients subjectively reported less pressure and confinement sensation when compared to the T-mask. No adverse events were observed. Conclusion: The proposed total inverse planning paradigm using a 3D-printed immobilization device is feasible and renders comparable inter-fraction performance while offering a better patient experience, potentially improving cnsRT workflows and its cost-effectiveness.

3.
Int J Part Ther ; 9(4): 261-268, 2023.
Article in English | MEDLINE | ID: mdl-37169009

ABSTRACT

Purpose: Photon radiation therapy (RT) is important in the treatment of many brain tumors but can negatively affect neurocognition. Proton therapy (PT) can reduce doses to normal brain structures. We compared photon and proton plans to estimate the potential benefit in cognition if the patient were treated with PT. Materials and Methods: We analyzed 23 adult patients with proton and photon plans for the treatment of a primary brain tumor. Cognitive outcomes were predicted using converted equivalent dose (EQD2) with an α/ß ratio of 3 to left temporal lobe and normal brain tissue. Risks of cognitive decline on 2 specific tests, the Controlled Oral Word Association Test (COWAT [letter S], a test of verbal fluency) and the Wechler Adult Intelligence Scale (WAIS-IV Coding Test, a test of processing speed) were derived from a previously published model. Results: Dose reductions to left temporal lobe and normal brain tissue translated into lower estimated probabilities of impairment in specific neurocognitive test scores after PT. With a mean dose reduction from 1490 to 1092 cGy in EQD2 to the left temporal lobe (P < .001), there was reduction in probability of impairment in the COWAT (Letter S) test from 6.8% to 5.4%. Similar results were seen with the normal brain (750 to 451 cGy in EQD2, P < .001), with reduction in probability of impairment in the WAIS-IV Coding test from 5% to 4.1%. Other structures experiencing dose reduction with PT included each cochlea, posterior fossa, each temporal lobe, and each hippocampus. Conclusion: We confirmed an association between PT and lower doses to brain substructures, which is expected to result in a modest decrease in probability of impairment in neurocognitive test scoring. These findings should be confirmed in prospective cohorts of patients treated with PT.

4.
Radiother Oncol ; 122(3): 458-463, 2017 03.
Article in English | MEDLINE | ID: mdl-28169043

ABSTRACT

PURPOSE: To determine the value of preoperative adaptive radiotherapy (ART) for soft tissue sarcoma patients (STS) by modeling the dosimetric consequences of tumour volume changes (TVC) using different external beam radiotherapy techniques. METHODS AND MATERIALS: A subset of 22 STS patients from a recent trial (NCT00188175) underwent a repeat CT scan (CT2) prompted by TVC>1cm during IMRT; 14 tumours grew, 8 shrank. Conformal and conventional plans were modelled in addition to IMRT replicating original criteria from the initial planning dataset (CT1):95% PTV encompassed by 97% prescribed dose. CT1 RT parameters for all plans were applied to CT2 for dosimetric assessment of TVC. Co-registration of CT1 and CT2 permitted comparison of original and new contours. RESULTS: Mean TVC was 45% for growing and 33% for the shrinking cohort with TVC prompting CT2 at a mean of 13 fractions. For growers, the lack of target coverage on CT2 was statistically significant but was adequate for shrinkers. CONCLUSION: GTV expansion of >1cm during RT may result in target underdosage independent of RT technique. ART applied offline for TV increases >1cm is a practical adaptive strategy to ensure tumour coverage during RT. TV shrinkage may allow for normal tissue sparing, which should be investigated prospectively.


Subject(s)
Radiotherapy, Intensity-Modulated , Sarcoma/radiotherapy , Humans , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods , Sarcoma/diagnostic imaging , Sarcoma/pathology , Tomography, X-Ray Computed/methods , Tumor Burden
5.
Int J Radiat Oncol Biol Phys ; 92(1): 144-52, 2015 May 01.
Article in English | MEDLINE | ID: mdl-25670544

ABSTRACT

PURPOSE: Early-stage Hodgkin lymphoma (HL) is a rare disease, and the location of lymphoma varies considerably between patients. Here, we evaluate the variability of radiation therapy (RT) plans among 5 International Lymphoma Radiation Oncology Group (ILROG) centers with regard to beam arrangements, planning parameters, and estimated doses to the critical organs at risk (OARs). METHODS: Ten patients with stage I-II classic HL with masses of different sizes and locations were selected. On the basis of the clinical information, 5 ILROG centers were asked to create RT plans to a prescribed dose of 30.6 Gy. A postchemotherapy computed tomography scan with precontoured clinical target volume (CTV) and OARs was provided for each patient. The treatment technique and planning methods were chosen according to each center's best practice in 2013. RESULTS: Seven patients had mediastinal disease, 2 had axillary disease, and 1 had disease in the neck only. The median age at diagnosis was 34 years (range, 21-74 years), and 5 patients were male. Of the resulting 50 treatment plans, 15 were planned with volumetric modulated arc therapy (1-4 arcs), 16 with intensity modulated RT (3-9 fields), and 19 with 3-dimensional conformal RT (2-4 fields). The variations in CTV-to-planning target volume margins (5-15 mm), maximum tolerated dose (31.4-40 Gy), and plan conformity (conformity index 0-3.6) were significant. However, estimated doses to OARs were comparable between centers for each patient. CONCLUSIONS: RT planning for HL is challenging because of the heterogeneity in size and location of disease and, additionally, to the variation in choice of treatment techniques and field arrangements. Adopting ILROG guidelines and implementing universal dose objectives could further standardize treatment techniques and contribute to lowering the dose to the surrounding OARs.


Subject(s)
Head and Neck Neoplasms/radiotherapy , Hodgkin Disease/radiotherapy , Mediastinal Neoplasms/radiotherapy , Organs at Risk/radiation effects , Radiation Oncology/standards , Radiotherapy Planning, Computer-Assisted/methods , Adult , Aged , Axilla , Breast/radiation effects , Cancer Care Facilities/standards , Female , Head and Neck Neoplasms/drug therapy , Head and Neck Neoplasms/pathology , Heart/diagnostic imaging , Heart/radiation effects , Hodgkin Disease/drug therapy , Hodgkin Disease/pathology , Humans , Lung/diagnostic imaging , Lung/radiation effects , Male , Mediastinal Neoplasms/drug therapy , Mediastinal Neoplasms/pathology , Middle Aged , Organs at Risk/diagnostic imaging , Radiography , Radiotherapy Dosage , Radiotherapy, Conformal/methods , Radiotherapy, Intensity-Modulated/methods , Thyroid Gland/diagnostic imaging , Thyroid Gland/radiation effects , Young Adult
6.
Pract Radiat Oncol ; 4(3): 174-180, 2014.
Article in English | MEDLINE | ID: mdl-24766684

ABSTRACT

PURPOSE: Active breathing control (ABC) is emerging as a tool to reduce heart and lung dose for lymphoma patients receiving mediastinal radiation therapy (RT). The objective of this study was to report our early institutional experience with this technique, with emphasis on quantifying the changes in normal tissue dose and exploring factors that could be used to select patients with the greatest benefit. METHODS AND MATERIALS: Patients receiving mediastinal involved-field RT (IFRT) for lymphoma were eligible. The ABC was performed using a moderate deep-inspiration breath-hold (mDIBH) technique. All patients were replanned with free-breathing (FB) computed tomographic data sets and comparisons of lung, cardiac, and female breast tissue doses were made between mDIBH and FB plans. Logistic regression models were used to identify factors associated with improvement in mean lung and heart dose with mDIBH. RESULTS: Forty-seven patients were analyzed; the majority (87.2%) had Hodgkin lymphoma. Median prescribed dose was 30 Gy (range, 20-36 Gy), with 78.7% of cases being treated with parallel-opposed beams. The use of mDIBH significantly improved average mean lung dose (FB: 11.0 Gy; mDIBH: 9.5 Gy; P < .0001), lung V20 (28% vs 22%; P < .0001), and mean heart dose (14.3 Gy vs 11.8 Gy; P = .003), but increased the mean breast dose (FB: 3.0 Gy; mDIBH 3.6 Gy; P = .0005). The magnitude of diaphragmatic excursion on the inhale scan was significantly associated with dosimetric improvement in both heart and lung dose with mDIBH. CONCLUSIONS: Mediastinal IFRT for lymphoma delivered with mDIBH can significantly reduce lung and heart dose compared with FB, although not for all patients, and may increase breast dose in females. Its implementation is achievable in both adult and pediatric populations. Further work is necessary to better predict which patients benefit from this technique.


Subject(s)
Breathing Exercises/methods , Lymphoma/radiotherapy , Radiotherapy Planning, Computer-Assisted/methods , Adolescent , Adult , Aged , Dose Fractionation, Radiation , Female , Humans , Inhalation , Lymphoma/diagnostic imaging , Male , Middle Aged , Radiography , Retrospective Studies , Young Adult
7.
Neuro Oncol ; 15(10): 1413-9, 2013 Oct.
Article in English | MEDLINE | ID: mdl-24057886

ABSTRACT

BACKGROUND: Spine stereotactic body radiotherapy (SBRT) is increasingly being applied to the postoperative spine metastases patient. Our aim was to identify clinical and dosimetric predictors of local control (LC) and survival. METHODS: Eighty patients treated between October 2008 and February 2012 with postoperative SBRT were identified from our prospective database and retrospectively reviewed. RESULTS: The median follow-up was 8.3 months. Thirty-five patients (44%) were treated with 18-26 Gy in 1 or 2 fractions, and 45 patients (56%) with 18-40 Gy in 3-5 fractions. Twenty-one local failures (26%) were observed, and the 1-year LC and overall survival (OS) rates were 84% and 64%, respectively. The most common site of failure was within the epidural space (15/21, 71%). Multivariate proportional hazards analysis identified systemic therapy post-SBRT as the only significant predictor of OS (P = .02) and treatment with 18-26 Gy/1 or 2 fractions (P = .02) and a postoperative epidural disease grade of 0 or 1 (0, no epidural disease; 1, epidural disease that compresses dura only, P = .003) as significant predictors of LC. Subset analysis for only those patients (n = 48/80) with high-grade preoperative epidural disease (cord deformed) indicated significantly greater LC rates when surgically downgraded to 0/1 vs 2 (P = .0009). CONCLUSIONS: Postoperative SBRT with high total doses ranging from 18 to 26 Gy delivered in 1-2 fractions predicted superior LC, as did postoperative epidural grade.


Subject(s)
Epidural Neoplasms/surgery , Neoplasms/surgery , Postoperative Complications , Radiosurgery , Spinal Neoplasms/surgery , Adolescent , Adult , Aged , Aged, 80 and over , Epidural Neoplasms/pathology , Female , Follow-Up Studies , Humans , Male , Middle Aged , Neoplasm Staging , Neoplasms/pathology , Prognosis , Prospective Studies , Retrospective Studies , Spinal Neoplasms/secondary , Survival Rate , Young Adult
8.
Int J Radiat Oncol Biol Phys ; 82(4): 1528-34, 2012 Mar 15.
Article in English | MEDLINE | ID: mdl-21640506

ABSTRACT

PURPOSE: To examine the geometric relationship between local recurrence (LR) and external beam radiotherapy (RT) volumes for soft-tissue sarcoma (STS) patients treated with function-preserving surgery and RT. METHODS AND MATERIALS: Sixty of 768 (7.8%) STS patients treated with combined therapy within our institution from 1990 through 2006 developed an LR. Thirty-two received preoperative RT, 16 postoperative RT, and 12 preoperative RT plus a postoperative boost. Treatment records, RT simulation images, and diagnostic MRI/CT data sets of the original and LR disease were retrospectively compared. For LR location analysis, three RT target volumes were defined according to the International Commission on Radiation Units and Measurements 29 as follows: (1) the gross tumor or operative bed; (2) the treatment volume (TV) extending 5 cm longitudinally beyond the tumor or operative bed unless protected by intact barriers to spread and at least 1-2 cm axially (the TV was enclosed by the isodose curve representing the prescribed target absorbed dose [TAD] and accounted for target/patient setup uncertainty and beam characteristics), and (3) the irradiated volume (IRV) that received at least 50% of the TAD, including the TV. LRs were categorized as developing in field within the TV, marginal (on the edge of the IRV), and out of field (occurring outside of the IRV). RESULTS: Forty-nine tumors relapsed in field (6.4% overall). Nine were out of field (1.1% overall), and 2 were marginal (0.3% overall). CONCLUSIONS: The majority of STS tumors recur in field, indicating that the incidence of LR may be affected more by differences in biologic and molecular characteristics rather than aberrations in RT dose or target volume coverage. In contrast, only two patients relapsed at the IRV boundary, suggesting that the risk of a marginal relapse is low when the TV is appropriately defined. These data support the accurate delivery of optimal RT volumes in the most precise way using advanced technology and image guidance.


Subject(s)
Neoplasm Recurrence, Local , Sarcoma/radiotherapy , Sarcoma/surgery , Adolescent , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Neoplasm Recurrence, Local/diagnostic imaging , Neoplasm Recurrence, Local/pathology , Organ Sparing Treatments/methods , Radiography , Retrospective Studies , Sarcoma/diagnostic imaging , Sarcoma/pathology , Tumor Burden , Young Adult
9.
Int J Radiat Oncol Biol Phys ; 78(5): 1437-44, 2010 Dec 01.
Article in English | MEDLINE | ID: mdl-20350788

ABSTRACT

PURPOSE: To evaluate inter- and intrafractional motion and rotational error for lower extremity soft tissue sarcoma patients by using cone beam computed tomography (CBCT) and an optical localization system. METHODS AND MATERIALS: Thirty-one immobilized patients received CBCT image-guided intensity-modulated radiation therapy. Setup deviations of >3 mm from the planned isocenter were corrected. A second CBCT acquired before treatment delivery was registered to the planning CT to estimate interfractional setup error retrospectively. Interfractional error and rotational error were calculated in the left-right (LR), superoinferior (SI), and anteroposterior (AP) dimensions. Intrafractional motion was assessed by calculating the maximum relative displacement of optical localization system reflective markers placed on the patient's surface, combined with pre- and postfraction CBCT performed for 17 of the 31 patients once per week. The overall systematic error (SE) and random error (RE) were calculated for the interfractional and intrafractional motion for planning target volume margin calculation. RESULTS: The standard deviation (SD) of the interfractional RE was 1.9 mm LR, 2.1 mm SI, and 1.8 mm AP, and the SE SD was 0.6 mm, 1.2 mm, and 0.7 mm in each dimension, respectively. The overall rotation (inter- and intrafractional) had an RE SD of 0.8° LR, 1.7° SI, and 0.7° AP and an SE SD of 1.1° LR, 1.3° SI, and 0.3° AP. The SD of the overall intrafractional RE was 1.6 mm LR, 1.6 mm SI, and 1.4 mm AP, and the SE SD was 0.7 mm AP, 0.6 mm SI, and 0.6 mm AP. CONCLUSIONS: A uniform 5-mm planning target volume margin was quantified for lower extremity soft tissue sarcoma patients and has been implemented clinically for image-guided intensity-modulated radiation therapy.


Subject(s)
Cone-Beam Computed Tomography , Lower Extremity/diagnostic imaging , Movement , Radiotherapy, Intensity-Modulated/methods , Sarcoma/diagnostic imaging , Sarcoma/radiotherapy , Humans , Lower Extremity/surgery , Male , Preoperative Care , Radiotherapy Planning, Computer-Assisted/methods , Retrospective Studies , Rotation , Sarcoma/surgery
10.
Med Dosim ; 34(3): 243-9, 2009.
Article in English | MEDLINE | ID: mdl-19647636

ABSTRACT

The purpose of this study was to determine the accuracy and efficiency of a custom-designed immobilization device for patients with extremity soft-tissue sarcoma. The custom device consisted of a thermoplastic shell, vacuum pillow, and adaptable baseplate. The study included patients treated from January 2005 to March 2007, with 92 patients immobilized with the custom device and 98 with an established standard. Setup times for these cohorts were analyzed retrospectively for conformal and intensity modulated radiotherapy techniques (IMRT). Thigh tumor setup times were analyzed independently. A subset of patients treated with IMRT was analyzed for setup error using the radiographically verified isocenter position measured daily with electronic portal imaging and cone-beam computed tomography. Mean setup time was reduced by 2.2 minutes when using the custom device for conformal treatment (p = 0.03) and by 5.8 min for IMRT of thigh tumors (p = 0.009). All other setup time comparisons were not significant. A significant systematic error reduction was seen in all directions using the custom device. Random error standard deviations favored the custom device. The custom device offers immobilization advantages. Patient setup time was reduced for conformal techniques and IMRT of thigh tumors. Positioning uncertainty was improved, permitting a reduction of the planning target volume margin by 2 to 4 mm.


Subject(s)
Immobilization/instrumentation , Immobilization/methods , Limb Salvage/instrumentation , Limb Salvage/methods , Radiotherapy, Conformal/instrumentation , Radiotherapy, Conformal/methods , Sarcoma/radiotherapy , Equipment Design , Equipment Failure Analysis , Humans , Reproducibility of Results , Sensitivity and Specificity
11.
Int J Radiat Oncol Biol Phys ; 75(4): 1119-24, 2009 Nov 15.
Article in English | MEDLINE | ID: mdl-19362782

ABSTRACT

PURPOSE: To examine the relationship between tumor location, bone dose, and irradiated bone length on the development of radiation-induced fractures for lower extremity soft tissue sarcoma (LE-STS) patients treated with limb-sparing surgery and radiotherapy (RT). METHODS AND MATERIALS: Of 691 LE-STS patients treated from 1989 to 2005, 31 patients developed radiation-induced fractures. Analysis was limited to 21 fracture patients (24 fractures) who were matched based on tumor size and location, age, beam arrangement, and mean total cumulative RT dose to a random sample of 53 nonfracture patients and compared for fracture risk factors. Mean dose to bone, RT field size (FS), maximum dose to a 2-cc volume of bone, and volume of bone irradiated to >or=40 Gy (V40) were compared. Fracture site dose was determined by comparing radiographic images and surgical reports to fracture location on the dose distribution. RESULTS: For fracture patients, mean dose to bone was 45 +/- 8 Gy (mean dose at fracture site 59 +/- 7 Gy), mean FS was 37 +/- 8 cm, maximum dose was 64 +/- 7 Gy, and V40 was 76 +/- 17%, compared with 37 +/- 11 Gy, 32 +/- 9 cm, 59 +/- 8 Gy, and 64 +/- 22% for nonfracture patients. Differences in mean, maximum dose, and V40 were statistically significant (p = 0.01, p = 0.02, p = 0.01). Leg fractures were more common above the knee joint. CONCLUSIONS: The risk of radiation-induced fracture appears to be reduced if V40 <64%. Fracture incidence was lower when the mean dose to bone was <37 Gy or maximum dose anywhere along the length of bone was <59 Gy. There was a trend toward lower mean FS for nonfracture patients.


Subject(s)
Fractures, Bone/etiology , Leg Injuries/etiology , Radiation Injuries/complications , Sarcoma/radiotherapy , Female , Femoral Fractures/etiology , Fibula , Humans , Male , Middle Aged , Radiotherapy Dosage , Risk Assessment , Salvage Therapy/adverse effects , Sarcoma/pathology , Sarcoma/surgery , Sex Factors , Tibial Fractures/etiology , Tumor Burden
SELECTION OF CITATIONS
SEARCH DETAIL
...