1.
J Appl Clin Med Phys ; 17(4): 114-123, 2016 07 08.
Article in English | MEDLINE | ID: mdl-27455486

ABSTRACT

In this work, overshoot and undershoot effects associated with step-and-shoot IMRT (SSIMRT) delivery on a Varian Clinac 21iX are investigated, and their impact on patient-specific QA point dose measurements and treatment plan delivery are evaluated. Pinnacle3 SSIMRT plans consisting of 5, 10, and 15 identical 5 × 5 cm2 MLC defined segments and MU/segment values of 5 MU, 10 MU, and 20 MU were utilized and delivered at 600/300 MU/min. Independent of the number of segments the overshoot and undershoot at 600 MU/min were approximately ± 10%, ± 5%, and ± 2.5% for 5 MU/segment, 10 MU/segment, and 20 MU/segment, respectively. At 300 MU/min, each of these values is approximately halved. Interfractional variation of these effects (10 fractions), as well as dosimetric variations for intermediate segments, are reduced at the lower dose rate. QA point-dose measurements for a sample (n = 29) of head and neck SSIMRT beams were on average 2.9% (600 MU/min) and 1.7% (300 MU/min) higher than Pinnacle3 planned doses. In comparison for prostate beams (n = 46), measured point doses were 0.8% (600 MU/min) and 0.4% (300 MU/min) higher. The reduction in planned-measured point-dose discrepancies at 300 MU/min can be attributed in part to the inclusion of the first segment (overshoot) in the admixture of segments that deliver measured dose. Pinnacle3 plans for 10/9 head and neck/prostate treatments were adjusted by ± 0.5 MU to include the effects of overshoot and undershoot at 600 MU/min. Comparing original and adjusted plans for each site indicated that the original plan was preferred in 70% and 89% of head and neck and prostate cases, respectively. The disparity between planned and delivered treatment that this suggests can potentially be mitigated by treating SSIMRT at a dose rate below 600 MU/min.


Subject(s)
Head and Neck Neoplasms/radiotherapy , Particle Accelerators/standards , Patient Care Planning , Prostatic Neoplasms/radiotherapy , Quality Assurance, Health Care/standards , Radiotherapy Planning, Computer-Assisted/instrumentation , Head and Neck Neoplasms/pathology , Humans , Male , Prostatic Neoplasms/pathology , Quality Control , Radiometry , Radiotherapy Dosage , Radiotherapy, Intensity-Modulated , Retrospective Studies
2.
J Med Imaging Radiat Oncol ; 59(1): 91-8, 2015 Feb.
Article in English | MEDLINE | ID: mdl-24953244

ABSTRACT

INTRODUCTION: This investigation aimed to assess the consistency and accuracy of radiation therapists (RTs) performing cone beam computed tomography (CBCT) alignment to fiducial markers (FMs) (CBCTFM ) and the soft tissue prostate (CBCTST ). METHODS: Six patients receiving prostate radiation therapy underwent daily CBCTs. Manual alignment of CBCTFM and CBCTST was performed by three RTs. Inter-observer agreement was assessed using a modified Bland-Altman analysis for each alignment method. Clinically acceptable 95% limits of agreement with the mean (LoAmean ) were defined as ±2.0 mm for CBCTFM and ±3.0 mm for CBCTST . Differences between CBCTST alignment and the observer-averaged CBCTFM (AvCBCTFM ) alignment were analysed. Clinically acceptable 95% LoA were defined as ±3.0 mm for the comparison of CBCTST and AvCBCTFM . RESULTS: CBCTFM and CBCTST alignments were performed for 185 images. The CBCTFM 95% LoAmean were within ±2.0 mm in all planes. CBCTST 95% LoAmean were within ±3.0 mm in all planes. Comparison of CBCTST with AvCBCTFM resulted in 95% LoA of -4.9 to 2.6, -1.6 to 2.5 and -4.7 to 1.9 mm in the superior-inferior, left-right and anterior-posterior planes, respectively. CONCLUSIONS: Significant differences were found between soft tissue alignment and the predicted FM position. FMs are useful in reducing inter-observer variability compared with soft tissue alignment. Consideration needs to be given to margin design when using soft tissue matching due to increased inter-observer variability. This study highlights some of the complexities of soft tissue guidance for prostate radiation therapy.


Subject(s)
Cone-Beam Computed Tomography/instrumentation , Patient Positioning/instrumentation , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/radiotherapy , Radiotherapy, Image-Guided/instrumentation , Subtraction Technique/instrumentation , Aged , Cone-Beam Computed Tomography/methods , Fiducial Markers , Humans , Male , Middle Aged , Observer Variation , Patient Positioning/methods , Radiotherapy, Image-Guided/methods , Reproducibility of Results , Sensitivity and Specificity , Treatment Outcome
3.
J Med Imaging Radiat Oncol ; 57(4): 519-23; quiz 524-5, 2013 Aug.
Article in English | MEDLINE | ID: mdl-23870354

ABSTRACT

INTRODUCTION: As the use of fiducial markers (FMs) for the localisation of the prostate during external beam radiation therapy (EBRT) has become part of routine practice, radiation therapists (RTs) have become increasingly responsible for online image interpretation. The aim of this investigation was to quantify the limits of agreement (LoA) between RTs when localising to FMs with orthogonal kilovoltage (kV) imaging. METHODS: Six patients receiving prostate EBRT utilising FMs were included in this study. Treatment localisation was performed using kV imaging prior to each fraction. Online stereoscopic assessment of FMs, performed by the treating RTs, was compared with the offline assessment by three RTs. Observer agreement was determined by pairwise Bland-Altman analysis. RESULTS: Stereoscopic analysis of 225 image pairs was performed online at the time of treatment, and offline by three RT observers. Eighteen pairwise Bland-Altman analyses were completed to assess the level of agreement between observers. Localisation by RTs was found to be within clinically acceptable 95% LoAs. CONCLUSIONS: Small differences between RTs, in both the online and offline setting, were found to be within clinically acceptable limits. RTs were able to make consistent and reliable judgements when matching FMs on planar kV imaging.


Subject(s)
Fiducial Markers , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/radiotherapy , Radiotherapy, Conformal/methods , Tomography, X-Ray Computed/methods , Humans , Male , Observer Variation , Reproducibility of Results , Sensitivity and Specificity
4.
Dalton Trans ; (39): 4446-56, 2007 Oct 21.
Article in English | MEDLINE | ID: mdl-17909656

ABSTRACT

The new square-planar platinum-diimine-dithiolate compounds [Pt(mesBIAN)SS] have been synthesised {mesBIAN = bis(mesityl)biazanaphthenequinone; SS = 1,2-dithiooxalate (dto) , maleonitriledithiolate (mnt) , 1,2-benzenedithiolate (bdt) , 3,4-toluenedithiolate (tdt) and 1,3-dithia-2-thione-4,5-dithiolate (dmit) }, and the X-ray crystal structures of and determined. Cyclic voltammetry reveals that all the compounds form stable anions, and ESR spectroscopy of these anions shows that the SOMO is based upon the mesBIAN ligand; compounds also show a reversible oxidation wave in their CV. Computational studies reveal that charge-transfer processes from orbitals that are combinations of metal and dithiolate ligand to a mesBIAN pi-based LUMO are responsible for the low energy absorptions seen in the UV/visible spectra of these compounds, and that the reverse process is responsible for the observed room-temperature solution luminescence of [Pt(mesBIAN)Cl(2)] and , and . Compounds and , containing aromatic thiolates, were not found to luminesce under the same conditions. Resonance Raman experiments have shown the origin of band-broadening of the lowest-energy absorption band in the absorption spectra of to be due to vibronic structure within one electronic transition.