Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Ann Vasc Surg ; 44: 136-145, 2017 Oct.
Article in English | MEDLINE | ID: mdl-28501659

ABSTRACT

BACKGROUND: Understanding the difference of Adamkiewicz artery (AKA) presentation in healthy and diseased subjects, and the influence of atherosclerotic factors prevalent in aortic disease patients, are important for aortic disease therapeutic planning. This study used a 320-detector row computed tomography (CT) device to examine the impact of clinical aspects of AKA identification in individuals with and without aortic disease. METHODS: Angio-CTs obtained from 115 patients were assessed and the individuals grouped according to the presence or absence of aortic disease. Datasets were analyzed using OsiriX software, and AKA was identified by three-dimensional multiplanar reconstruction. RESULTS: The group without aortic disease (Group A) comprised 32 (52.5%) men and 29 women, with a mean age of 53.7 ± 16.8 years. The group with aortic disease (Group B) comprised 31 (57.4%) men and 23 women, with a mean age of 64.8 ± 11.6 years. AKA was identified in 49 (80.3%) participants of Group A and 23 (42.6%) individuals of Group B (P ≤ 0.0001). In 53 cases (73.6%), AKA originated on the left side. AKA was mainly detected on the left side (73.6%), at the level of T10 to T12 (70%). Tobacco smokers, former smokers, and hypertensive patients had increased odds of having undetected AKA. CONCLUSIONS: Using the method described and a state of the art 320-detector row CT device, AKA was detected more frequently among individuals without aortic disease. Thus, aortic disease and atherosclerotic risk factors hindered AKA detection.


Subject(s)
Aortic Diseases/diagnostic imaging , Aortography/instrumentation , Arteries/diagnostic imaging , Computed Tomography Angiography/instrumentation , Multidetector Computed Tomography/instrumentation , Spinal Cord/blood supply , Tomography Scanners, X-Ray Computed , Adult , Aged , Case-Control Studies , Cross-Sectional Studies , Diagnostic Errors , Equipment Design , Female , Humans , Imaging, Three-Dimensional , Male , Middle Aged , Predictive Value of Tests , Radiographic Image Interpretation, Computer-Assisted
2.
Arq. bras. cardiol ; 56(3): 231-234, mar. 1991. ilus
Article in Portuguese | LILACS | ID: lil-93723

ABSTRACT

Dois pacientes com 31 anos de idade, internados por insuficiência cardíaca (classe funcional III), um com episódio de endocardite infecciosa na valva mitral há oito meses, outro com antecedentes de doença reumática, apresentaram insuficiência mitral importante, que motivou troca da valva mitral. Os achados operatórios incluíram a presença de aneurisma da valva mitral acometendo cúspide posterior em um e ambas no outro paciente. O estudo anótomopatológico identificou prolapso da valva mitral e sinais de endocardite prévia no primeiro e lesäo reumática no segundo caso


Subject(s)
Humans , Male , Adult , Heart Aneurysm/complications , Mitral Valve Insufficiency/complications , Endocarditis, Bacterial/complications , Heart Aneurysm/surgery , Heart Aneurysm/etiology , Heart Aneurysm/pathology , Mitral Valve Insufficiency/pathology
3.
Rev. bras. cir. cardiovasc ; 5(1): 26-34, abr. 1990. ilus, tab
Article in Portuguese | LILACS | ID: lil-164290

ABSTRACT

O objetivo deste trabalho é apresentar os resultados pós-operatórios preliminares de 16 pacientes submetidos a implante de bioprótese valvular de pericárdio bovino com preservaçao de suas valvas naturais, operados seqüencialmente no período de março a setembro de 1989. As cúspides insuficientes foram pregueadas no anel mitral com pontos em U passados nas bordas livres e no anel mitral, sem quaisquer ressecçoes. Foram feitos estudos comparativos no pré e no pós-operatório das seguintes grandezas: diâmetro do átrio esquerdo, diâmetro do ventrículo esquerdo (VE), fraçao de ejeçao e gradiente transvalvares mitrais (pico e médio). A avaliaçao estatística foi feita através do teste T de Student. O valor médio do diâmetro do VE no pré-operatório era de 67,31 mm, caindo para 60,50 mm no pós-operatório. O valor crítico de T foi 2,131, sendo o valor observado para a variaçao do diâmetro de VE igual a 3,18. O diâmetro de átrio esquerdo (AE) variou de 60,25 mm para 49,31 mm com T igual a 6,72. O valor médio da fraçao de ejeçao no pré-operatório foi de O,72, variando para O,65 com T igual a 2,68. Os gradientes (valores médios) transvalvares variaram de 23,7 mm de Hg de pico e 12,5 de média, respectivamente, para 9,10 e 5,125. Estes valores residuais sao perfeitamente aceitáveis de acordo com a literatura e a própria experiência do Serviço. Nao houve complicaçoes ou óbitos na série. Em nenhum paciente ocorreu gradiente na via de saída de VE que pudesse sugerir obstruçao pela cúspide anterior. Os autores concluem pela eficácia da técnica a qual é de fácil e rápida execuçao, afasta desinserçoes atrioventriculares, nao gera gradientes, favorece ótimo desempenho ventricular com rápida e acentuada regressao dos diâmetros de AE e VE.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Bioprosthesis , Heart Valve Prosthesis , Mitral Valve Insufficiency/surgery , Echocardiography , Mitral Valve , Pericardium , Reoperation , Stroke Volume
SELECTION OF CITATIONS