Ann Thorac Surg ; 51(2): 304-6; discussion 306-7, 1991 Feb.
Article in English | MEDLINE | ID: mdl-1989551

ABSTRACT

Endobronchial hemorrhage due to pulmonary artery perforation by a Swan-Ganz catheter developed during coronary artery bypass grafting while weaning from cardiopulmonary bypass. After reinstitution of cardio-pulmonary bypass with pulmonary artery venting, bleeding was localized to the right lower lobe bronchus using fiberoptic bronchoscopy. A Fogarty embolectomy catheter was inflated in the bronchus to tamponade successfully only the right lower lobe. This case illustrates a method of distal bronchial blockade for maximal retention of pulmonary function and avoidance of pulmonary resection.


Subject(s)
Blood Loss, Surgical , Bronchial Diseases/therapy , Catheterization, Swan-Ganz/adverse effects , Coronary Artery Bypass/adverse effects , Intraoperative Complications/therapy , Pulmonary Artery/injuries , Bronchial Diseases/etiology , Bronchoscopy , Humans , Male , Middle Aged , Rupture