Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Circ Arrhythm Electrophysiol ; 17(4): e012717, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38390748

ABSTRACT

BACKGROUND: The effect of contact force (CF) on lesion formation is not clear during pulsed field ablation (PFA). The aim of this study was to evaluate the impact of CF, PFA, and their interplay through the PFA index (PF index) formula on the ventricular lesion size in swine. METHODS: PFA was delivered through the CF-sensing OMNYPULSE catheter. Predefined PFA applications (×3, ×6, ×9, and ×12) were delivered maintaining low (5-25 g), high (26-50 g), and very high (51-80 g) CFs. First, PFA lesions were evaluated on necropsy in 11 swine to investigate the impact of CF/PFA-and their integration in the PF index equation-on lesion size (study characterization). Then, 3 different PF index thresholds-300, 450, and 600-were tested in 6 swine to appraise the PF index accuracy to predict the ventricular lesion depth (study validation). RESULTS: In the study characterization data set, 111 PFA lesions were analyzed. CF was 32±17 g. The average lesion depth and width were 3.5±1.2 and 12.0±3.5 mm, respectively. More than CF and PFA dose alone, it was their combined effect to impact lesion depth through an asymptotically increasing relationship. Likewise, not only was the PF index related to lesion depth in the study validation data set (r2=0.66; P<0.001) but it also provided a prediction accuracy of the observed depth of ±2 mm in 69/73 lesions (95%). CONCLUSIONS: CF and PFA applications play a key role in lesion formation during PFA. Further studies are required to evaluate the best PFA ablation settings to achieve transmural lesions.


Subject(s)
Catheter Ablation , Swine , Animals , Catheter Ablation/adverse effects , Heart Ventricles/surgery , Catheters , Equipment Design
2.
JACC Clin Electrophysiol ; 6(2): 171-181, 2020 02.
Article in English | MEDLINE | ID: mdl-32081219

ABSTRACT

OBJECTIVES: This study sought to validate the accuracy of noncontact electrograms against contact electrograms in the left atrium during sinus rhythm (SR) and atrial fibrillation (AF). BACKGROUND: Noncontact mapping offers the opportunity to assess global cardiac activation in the chamber of interest. A novel noncontact mapping system, which records intracardiac voltage to derive cellular charge sources (dipole density), allows real-time mapping of AF to guide ablation. METHODS: Noncontact and contact unipolar electrogram pairs were recorded simultaneously from multiple locations. Morphology correlation and timing difference of reconstructed electrograms obtained from a noncontact catheter were compared with those from contact electrograms obtained from a contact catheter at the same endocardial locations. RESULTS: A total of 796 electrogram pairs in SR and 969 electrogram pairs in AF were compared from 20 patients with persistent AF. The median morphology correlation and timing difference (ms) in SR was 0.85 (interquartile range [IQR]: 0.71 to 0.94) and 6.4 ms (IQR: 2.6 to 17.1 ms); in AF was 0.79 (IQR: 0.69 to 0.88) and 14.4 ms (IQR: 6.7 to 26.2 ms), respectively. The correlation was stronger and the timing difference was less when the radial distance (r) from the noncontact catheter center to the endocardium was ≤ 40 versus > 40 mm; 0.87 (IQR: 0.72 to 0.94) versus 0.73 (IQR: 0.56 to 0.88) and 5.7 ms (IQR: 2.6 to 15.4 ms) versus 15.1 ms (IQR: 4.1 to 27.7 ms); p < 0.01 when in SR; 0.81 (IQR: 0.69 to 0.89) versus 0.67 (IQR: 0.45 to 0.82) and 12.3 ms (IQR: 5.9 to 21.8 ms) versus 28.3 ms (IQR: 16.2 to 36.0 ms); p < 0.01 when in AF. CONCLUSIONS: This novel noncontact dipole density mapping system provides comparable reconstructed atrial electrogram measurements in SR or AF in human left atrium when the anatomical site of interest is ≤40 mm from the mapping catheter.


Subject(s)
Atrial Fibrillation/physiopathology , Electrophysiologic Techniques, Cardiac/methods , Heart Atria/physiopathology , Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Catheter Ablation , Electrophysiologic Techniques, Cardiac/standards , Female , Humans , Male , Middle Aged , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL
...