ABSTRACT

Recent advances in wearable patches have included various sensors to monitor either physiological signs, such as the heart rate and respiration rate, or metabolites. Nevertheless, most of these have focused only on a single physiological measurement at a time, which significantly inhibits the calibration of various biological signals and diagnostic facilities. In this study, a novel multifunctional hybrid skin patch was developed for the electrochemical analysis of sweat glucose levels and simultaneous monitoring of electrocardiograms (ECGs). Furthermore, pH and temperature sensors were co-integrated onto the same patch for the calibration of the glucose biosensor to prevent inevitable inhibition and weakening of enzyme activity due to changes in the sweat pH and temperature levels. The fabricated electrochemical glucose biosensor exhibited excellent linearity (R2 = 0.9986) and sensitivity (29.10 µA mM-1 cm-2), covering the normal range of human sweat. The potentiometric pH sensor displayed a good response with an excellent sensitivity of -77.81 mV/pH and high linearity (R2 = 0.991), indicating that it can distinguish variations in the typical pH range for human sweat. Furthermore, the P, QRS complex, and T peaks in the measured ECG waveforms could be clearly distinguished, indicating the reliability of the fabricated flexible dry electrodes for continuous monitoring. The fabricated skin patch overcomes the inconvenience of the mandatory attachment of multiple patches on the human body by fully integrating all the electrochemical and electrophysiological sensors on a single patch, thus facilitating advanced glycemic control and continuous ECG monitoring for smart management of chronic diseases and healthcare applications.


Subject(s)
Biosensing Techniques , Wearable Electronic Devices , Delivery of Health Care , Humans , Reproducibility of Results , Sweat
2.
Adv Sci (Weinh) ; 8(15): e2100711, 2021 08.
Article in English | MEDLINE | ID: mdl-34075718

ABSTRACT

Cyberattack is one of the severe threats in the digital world as it encompasses everything related to personal information, health, finances, intellectual properties, and even national security. Password-based authentication is the most practiced authentication system, however, is vulnerable to several attacks such as dictionary attack, shoulder surfing attack, and guessing attack. Here, a new keystroke dynamics-based hybrid nanogenerator for biometric authentication and identification integrated with artificial intelligence (AI) is reported. Keystroke dynamics offer behavioral and contextual information that can distinguish and authorize the individuals based on their typing rhythms. The hybrid electromagnetic-triboelectric nanogenerators/sensors efficiently convert the keystroke mechanical energy into electrical signals, which are fed into an artificial neural network based AI system. The self-powered hybrid sensors-based biometric authentication system integrated with a neural network achieves an accuracy of 99% and offers a promising hybrid security layer against password vulnerability.

3.
Biosens Bioelectron ; 186: 113287, 2021 Apr 29.
Article in English | MEDLINE | ID: mdl-33962178

ABSTRACT

Due to the insufficiency of binding sites for the immobilized recognition biomolecules on the immunosensing platform, cancer detection becomes challenging. Whereas, the degradation of black phosphorene (BP) in the presence of the environmental factors becomes a concerning issue for use in electrochemical sensing. In this study, BP is successfully encapsulated by polyallylamine (PAMI) to increase its stability as well as to enhance its electrochemical performance. The successful encapsulation of BP is ensured through X-ray Photoelectron spectroscopy and Raman spectroscopy, whereas the stability of black phosphorus is ensured by Zeta potential measurements and cyclic voltammetry tests. The developed BP-PAMI composite showed high stability in the ambient environment and exhibited improved electrochemical performances. The impedimetric immunosensor was developed on a BP-PAMI modified laser burned graphene (LBG) to detect interleukin-6 biomarkers using electrochemical impedance spectroscopy (EIS). Under the optimized parameters, the fabricated immunosensor demonstrated a wide linear range of 0.003-75 ng/mL, limit of detection (LOD) of 1 pg/mL. Based on the experimental analysis, the developed sensing strategy can be employed as an easy, disposable, cost-effective and highly selective point-of-care cancer detection. In addition, the developed technique can be applied broadly for detecting other biomarkers after treating with suitable biomolecules.

4.
ACS Appl Mater Interfaces ; 13(4): 4955-4967, 2021 Feb 03.
Article in English | MEDLINE | ID: mdl-33475336

ABSTRACT

Understanding of the triboelectric charge accumulation from the view of microcapacitor formation plays a critical role in boosting the output performance of the triboelectric nanogenerator (TENG). Here, an electrospun nanofiber-based TENG (EN-TENG) using a poly(vinylidene fluoride-trifluoroethylene) (PVDF-TrFE)/MXene nanocomposite material with superior dielectric constant and high surface charge density is reported. The influence of dielectric properties on the output performance of the EN-TENG is investigated theoretically and experimentally. The fabricated EN-TENG exhibited a maximum power density of 4.02 W/m2 at a matching external load resistance of 4 MΩ. The PVDF-TrFE/MXene nanocomposite improved the output performance of the EN-TENG fourfold. The EN-TENG successfully powered an electronic stopwatch and thermo-hygrometer by harvesting energy from human finger tapping. Moreover, it was utilized in smart home applications as a self-powered switch for controlling electrical home appliances, including fire alarms, fans, and smart doors. This work presents an effective and innovative approach toward self-powered systems, human-machine interfaces, and smart home applications.

5.
ACS Nano ; 15(3): 4380-4393, 2021 03 23.
Article in English | MEDLINE | ID: mdl-33444498

ABSTRACT

Recently, flexible capacitive pressure sensors have received significant attention in the field of wearable electronics. The high sensitivity over a wide linear range combined with long-term durability is a critical requirement for the fabrication of reliable pressure sensors for versatile applications. Herein, we propose a special approach to enhance the sensitivity and linearity range of a capacitive pressure sensor by fabricating a hybrid ionic nanofibrous membrane as a sensing layer composed of Ti3C2Tx MXene and an ionic salt of lithium sulfonamides in a poly(vinyl alcohol) elastomer matrix. The reversible ion pumping triggered by a hydrogen bond in the hybrid sensing layer leads to high sensitivities of 5.5 and 1.5 kPa-1 in the wide linear ranges of 0-30 and 30-250 kPa, respectively, and a fast response time of 70.4 ms. In addition, the fabricated sensor exhibits a minimum detection limit of 2 Pa and high durability over 20 000 continuous cycles even under a high pressure of 45 kPa. These results indicate that the proposed sensor can be potentially used in mobile medical monitoring devices and next-generation artificial e-skin.


Subject(s)
Nanofibers , Wearable Electronic Devices , Hydrogen , Hydrogen Bonding , Pressure
6.
Biosens Bioelectron ; 175: 112844, 2021 Mar 01.
Article in English | MEDLINE | ID: mdl-33248878

ABSTRACT

In this study, an ultra-high sensitive, flexible, wireless, battery-free, and fully integrated (no external analysis equipment) electrochemical sensing patch system, including a microfluidic-sweat collecting unit, was newly developed for the on-site monitoring of the [K+] concentration in human sweat. Multiwalled carbon nanotube (MWCNT) and MXene-Ti3C2TX based hybrid multi-dimensional networks were applied to obtain a high surface activation area and faster charge transfer rate, strongly adsorbing the valinomycin membrane to protect the ionophore for effective transshipment and immobilization of the [K+]. Furthermore, the controllable porosity of carbon-based materials can accelerate the kinetic process of ion diffusion. This hybrid nanonetwork structure effectively enhanced electrochemical stability and sensitivity, addressing the noise and signal drifting problems experienced with low concentration detection. The fabricated sensor exhibited a high ion concentration sensitivity of 63 mV/dec with excellent selectivity, amplified to 173 mV/dec with the integrated amplification system. The Near Field Communication (NFC) is used to transmit measurements to a smartphone wirelessly. A microfluidic channel was integrated with the electrochemical sensor patch to efficiently collect sweat on the human skin surface and mitigate the sensor surface contamination problem. Furthermore, the developed sensing patch can also be applied to other biomarkers on-site detection after modifying the working electrode with the corresponding selective membranes.