Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Light Sci Appl ; 13(1): 122, 2024 May 28.
Article in English | MEDLINE | ID: mdl-38806499

ABSTRACT

As semiconductor devices shrink and their manufacturing processes advance, accurately measuring in-cell critical dimensions (CD) becomes increasingly crucial. Traditional test element group (TEG) measurements are becoming inadequate for representing the fine, repetitive patterns in cell blocks. Conventional non-destructive metrology technologies like optical critical dimension (OCD) are limited due to their large spot diameter of approximately 25 µm, which impedes their efficacy for detailed in-cell structural analysis. Consequently, there is a pressing need for small-spot and non-destructive metrology methods. To address this limitation, we demonstrate a microsphere-assisted hyperspectral imaging (MAHSI) system, specifically designed for small spot optical metrology with super-resolution. Utilizing microsphere-assisted super-resolution imaging, this system achieves an optical resolution of 66 nm within a field of view of 5.6 µm × 5.6 µm. This approach effectively breaks the diffraction limit, significantly enhancing the magnification of the system. The MAHSI system incorporating hyperspectral imaging with a wavelength range of 400-790 nm, enables the capture of the reflection spectrum at each camera pixel. The achieved pixel resolution, which is equivalent to the measuring spot size, is 14.4 nm/pixel and the magnification is 450X. The MAHSI system enables measurement of local uniformity in critical areas like corners and edges of DRAM cell blocks, areas previously challenging to inspect with conventional OCD methods. To our knowledge, this approach represents the first global implementation of microsphere-assisted hyperspectral imaging to address the metrology challenges in complex 3D structures of semiconductor devices.

2.
Light Sci Appl ; 11(1): 32, 2022 Feb 07.
Article in English | MEDLINE | ID: mdl-35132060

ABSTRACT

As smaller structures are being increasingly adopted in the semiconductor industry, the performance of memory and logic devices is being continuously improved with innovative 3D integration schemes as well as shrinking and stacking strategies. Owing to the increasing complexity of the design architectures, optical metrology techniques including spectroscopic ellipsometry (SE) and reflectometry have been widely used for efficient process development and yield ramp-up due to the capability of 3D structure measurements. However, there has been an increasing demand for a significant reduction in the physical spot diameter used in the SE technique; the spot diameter should be at least 10 times smaller than the cell dimension (~30 × 40 µm2) of typical dynamic random-access memory to be able to measure in-cell critical dimension (CD) variations. To this end, this study demonstrates a novel spectrum measurement system that utilizes the microsphere-assisted super-resolution effect, achieving extremely small spot spectral metrology by reducing the spot diameter to ~210 nm, while maintaining a sufficiently high signal-to-noise ratio. In addition, a geometric model is introduced for the microsphere-based spectral metrology system that can calculate the virtual image plane magnification and depth of focus, providing the optimal distance between the objective lens, microsphere, and sample to achieve the best possible imaging quality. The proof of concept was fully verified through both simulations and experiments for various samples. Thus, owing to its ultra-small spot metrology capability, this technique has great potential for solving the current metrology challenge of monitoring in-cell CD variations in advanced logic and memory devices.

3.
J Periodontal Implant Sci ; 40(6): 257-64, 2010 Dec.
Article in English | MEDLINE | ID: mdl-21246015

ABSTRACT

PURPOSE: Connective tissue reattachment to periodontally damaged root surfaces is one of the most important goals of periodontal therapy. The aim of this study was to develop a root conditioning agent that can demineralize and detoxify the infected root surface. METHODS: Dentin slices obtained from human teeth were treated with a novel root planing agent for 2 minutes and then washed with phosphate-buffered saline. Smear layer removal and type I collagen exposure were observed by scanning electron microscopy (SEM) and type I collagen immunostaining, respectively. Cell attachment and lipopolysaccharides (LPS) removal demonstrated the efficiency of the root conditioning agent. RESULTS: SEM revealed that the smear layer was entirely removed and the dentinal tubules were opened by the experimental gel. Type I collagen was exposed on the surfaces of the dentin slices treated by the experimental gel, which were compared with dentin treated with other root planing agents. Dentin slices treated with the experimental gel showed the highest number of attached fibroblasts and flattened cell morphology. The agar diffusion assay demonstrated that the experimental gel also has effective antimicrobial activity. Escherichia coli LPS were effectively removed from well plates by the experimental gel. CONCLUSIONS: These results demonstrated that this experimental gel is a useful tool for root conditioning of infected root surfaces and can also be applied for detoxification of ailing implant surface threads.

SELECTION OF CITATIONS
SEARCH DETAIL
...