1.
Taehan Yongsang Uihakhoe Chi ; 83(3): 632-644, 2022 May.
Article in English | MEDLINE | ID: mdl-36238508

ABSTRACT

Purpose: To determine the incidence of atypical ductal hyperplasia (ADH) in needle biopsy and the upgrade rate to carcinoma, and to evaluate difference in findings between the upgrade and non-upgrade groups. Materials and Methods: Among 9660 needle biopsies performed over 48 months, we reviewed the radiologic and histopathologic findings of ADH and compared the differences in imaging findings (mammography and breast US) and biopsy methods between the upgrade and non-upgrade groups. Results: The incidence of ADH was 1.7% (169/9660). Of 112 resected cases and 30 cases followed-up for over 2 years, 35 were upgraded to carcinoma (24.6%, 35/142). The upgrade rates were significantly different according to biopsy methods: US-guided core needle biopsy (US-CNB) (40.7%, 22/54) vs. stereotactic-vacuum-assisted biopsy (S-VAB) (16.0%, 12/75) vs. US-guided VAB (US-VAB) (7.7%, 1/13) (p = 0.002). Multivariable analysis showed that only US-CNB (odds ratio = 5.19, 95% confidence interval: 2.16-13.95, p < 0.001) was an independent predictor for pathologic upgrade. There was no upgrade when a sonographic mass was biopsied by US-VAB (n = 7). Conclusion: The incidence of ADH was relatively low (1.7%) and the upgrade rate was 24.6%. Surgical excision should be considered because of the considerable upgrade rate, except in the case of US-VAB.

2.
Medicine (Baltimore) ; 101(27): e29547, 2022 Jul 08.
Article in English | MEDLINE | ID: mdl-35801798

ABSTRACT

This study aimed to compare the background echotexture (BE) between automated breast ultrasound (ABUS) and handheld breast ultrasound (HHUS) and evaluate the correlation of BE with mammographic (MG) density and background parenchymal enhancement (BPE) on magnetic resonance imaging (MRI). A total of 212 women with newly diagnosed breast cancer who had undergone preoperative ABUS, HHUS, MG, and MRI were included. Two breast radiologists blinded to the menopausal status analyzed the BE of the contralateral breasts of the patients with breast cancer in consensus. The MG density and BPE of breast MRI on the radiologic reports were compared with the BE in the ultrasound. We used the cumulative link mixed model to compare the BE and Spearman rank correlation to evaluate the association between BE with MG density and BPE. BE was more heterogeneous in ABUS than in HHUS (P < .001) and in the premenopausal group than in the postmenopausal group (P < .001). The heterogeneity of BE in the premenopausal group was higher with ABUS than with HHUS (P = .013). BE and MG density showed a moderate correlation in the postmenopausal group, but a weak correlation in the premenopausal group. BE and BPE showed moderate correlations only in the premenopausal group. ABUS showed a more heterogeneous BE, especially in the premenopausal group. Therefore, more attention is required to interpret ABUS screening in premenopausal women.


Subject(s)
Breast Neoplasms , Ultrasonography, Mammary , Breast/diagnostic imaging , Breast/pathology , Breast Density , Breast Neoplasms/pathology , Female , Humans , Magnetic Resonance Imaging/methods , Ultrasonography, Mammary/methods
3.
Ultrasonography ; 41(3): 493-501, 2022 Jul.
Article in English | MEDLINE | ID: mdl-35430786

ABSTRACT

PURPOSE: The prevalence of the tall cell variant of papillary thyroid carcinoma (TCVPTC), which has a poor prognosis, has increased as its definition has been modified. We sought to investigate whether TCVPTC is different from the classic type on ultrasonography (US). METHODS: This study included 46 consecutive TCVPTC patients and 92 classic papillary thyroid carcinoma (PTC) patients who were confirmed surgically at the authors' institution. The US findings and pathologic reports of these patients were retrospectively reviewed. US features based on the Korean Thyroid Imaging Reporting and Data System, preoperative US suspicion for lymph node metastasis, and the presence of capsular location were evaluated. RESULTS: Univariable and multivariable analyses identified that TCVPTC showed more frequent irregular tumor margin (odds ratio [OR], 6.62; 95% confidence interval [CI], 1.46 to 30.09; P=0.014) and capsular location (OR, 4.63; 95% CI, 1.49 to 14.41; P=0.008) than classic PTC. Capsular location was an independent predictor of TCVPTC for tumors less than or equal to 1.5 cm in size (OR, 4.23; 95% CI, 1.12 to 15.92; P=0.033). Irregular margin was an independent predictor of TCVPTC for tumors larger than 1.5 cm (OR, 10.46; 95% CI, 1.16 to 94.48; P=0.037). Extrathyroidal extension was not significantly different between the two groups. CONCLUSION: The two key features of TCVPTC on US are frequent capsular location for tumors less than or equal to 1.5 cm in size and the higher likelihood of an irregular margin for tumors larger than 1.5 cm.

4.
Eur Radiol ; 32(6): 4056-4066, 2022 Jun.
Article in English | MEDLINE | ID: mdl-34989844

ABSTRACT

OBJECTIVES: This study aimed to investigate the predictability of breast MRI for pathologic complete response (pCR) by molecular subtype in patients with breast cancer receiving neoadjuvant chemotherapy (NAC) and investigate the MRI findings that can mimic residual malignancy. METHODS: A total of 506 patients with breast cancer who underwent MRI after NAC and underwent surgery between January and December 2018 were included. Two breast radiologists dichotomized the post-NAC MRI findings as radiologic complete response (rCR) and no-rCR. The diagnostic performance of MRI predicting pCR was evaluated. pCR was determined based on the final pathology reports. Tumors were divided according to hormone receptor (HR) and human epidermal growth factor receptor (HER) 2. Residual lesions on post-NAC MRI were divided into overt and subtle which classified as nodularity or delayed enhancement. Pearson's χ2 and Wilcoxon rank-sum tests were used for MRI findings causing false-negative pCR. RESULTS: The overall pCR rate was 30.04%. The overall accuracy for predicting pCR using MRI was 76.68%. The accuracy was significantly different by subtypes (p < 0.001), as follows in descending order: HR - /HER2 - (85.63%), HR + /HER2 - (82.84%), HR + /HER2 + (69.37%), and HR - /HER2 + (62.38%). MRI in the HR - /HER2 + type showed the highest false-negative rate (18.81%) for predicting pCR. The subtle residual enhancement observed only in the delayed phase was associated with false-negative findings (76.2%, p = 0.016). CONCLUSIONS: The diagnostic accuracy of MRI for predicting pCR differed by molecular subtypes. When the residual enhancement on MRI after NAC is subtle and seen only in the delayed phase, overinterpretation of residual tumors should be performed with caution. KEY POINTS: • In patients with breast cancer after completion of neoadjuvant chemotherapy, the diagnostic accuracy of MRI for predicting pathologic complete response (pCR) differed according to molecular subtype. • When residual enhancement on MRI is subtle and seen only in the delayed phase, this finding could be associated with false-negative pCR results.


Subject(s)
Breast Neoplasms , Neoadjuvant Therapy , Antineoplastic Combined Chemotherapy Protocols/therapeutic use , Breast/diagnostic imaging , Breast/metabolism , Breast/surgery , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/drug therapy , Breast Neoplasms/metabolism , Chemotherapy, Adjuvant , Female , Humans , Magnetic Resonance Imaging/methods , Neoadjuvant Therapy/methods , Neoplasm, Residual/pathology , Receptor, ErbB-2/metabolism , Retrospective Studies
5.
Korean J Radiol ; 23(2): 159-171, 2022 Feb.
Article in English | MEDLINE | ID: mdl-35029082

ABSTRACT

OBJECTIVE: This study aimed to investigate the impact of baseline values and temporal changes in body composition parameters, including skeletal muscle index (SMI) and visceral adipose tissue area (VAT), measured using serial computed tomography (CT) imaging on the prognosis of operable breast cancers in Asian patients. MATERIALS AND METHODS: This study retrospectively included 627 Asian female (mean age ± standard deviation [SD], 53.6 ± 8.3 years) who underwent surgery for stage I-III breast cancer between January 2011 and September 2012. Body composition parameters, including SMI and VAT, were semi-automatically calculated on baseline abdominal CT at the time of diagnosis and follow-up CT for post-treatment surveillance. Serial changes in SMI and VAT were calculated as the delta values. Multivariable Cox regression analysis was used to evaluate the association of baseline and delta SMI and VAT values with disease-free survival. RESULTS: Among 627 patients, 56 patients (9.2%) had breast cancer recurrence after a median of 40.5 months. The mean value ± SD of the baseline SMI and baseline VAT were 43.7 ± 5.8 cm²/m² and 72.0 ± 46.0 cm², respectively. The mean value of the delta SMI was -0.9 cm²/m² and the delta VAT was 0.5 cm². The baseline SMI and VAT were not significantly associated with disease-free survival (adjusted hazard ratio [HR], 0.983; 95% confidence interval [CI], 0.937-1.031; p = 0.475 and adjusted HR, 1.001; 95% CI, 0.995-1.006; p = 0.751, respectively). The delta SMI and VAT were also not significantly associated with disease-free survival (adjusted HR, 0.894; 95% CI, 0.766-1.043; p = 0.155 and adjusted HR, 1.001; 95% CI, 0.989-1.014; p = 0.848, respectively). CONCLUSION: Our study revealed that baseline and early temporal changes in SMI and VAT were not independent prognostic factors regarding disease-free survival in Asian patients undergoing surgery for breast cancer.


Subject(s)
Breast Neoplasms , Obesity, Abdominal , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/surgery , Female , Humans , Middle Aged , Muscle, Skeletal , Neoplasm Recurrence, Local/diagnostic imaging , Prognosis , Retrospective Studies , Tomography, X-Ray Computed
6.
NPJ Breast Cancer ; 8(1): 8, 2022 Jan 14.
Article in English | MEDLINE | ID: mdl-35031626

ABSTRACT

Patients with a biopsy diagnosis of ductal carcinoma in situ (DCIS) may be diagnosed with invasive breast cancer after excision. We evaluated the preoperative clinical and imaging predictors of DCIS that were associated with an upgrade to invasive carcinoma on final pathology and also compared the diagnostic performance of various statistical models. We reviewed the medical records; including mammography, ultrasound (US), and magnetic resonance imaging (MRI) findings; of 644 patients who were preoperatively diagnosed with DCIS and who underwent surgery between January 2012 and September 2018. Logistic regression and three machine learning methods were applied to predict DCIS underestimation. Among 644 DCIS biopsies, 161 (25%) underestimated invasive breast cancers. In multivariable analysis, suspicious axillary lymph nodes (LNs) on US (odds ratio [OR], 12.16; 95% confidence interval [CI], 4.94-29.95; P < 0.001) and high nuclear grade (OR, 1.90; 95% CI, 1.24-2.91; P = 0.003) were associated with underestimation. Cases with biopsy performed using vacuum-assisted biopsy (VAB) (OR, 0.42; 95% CI, 0.27-0.65; P < 0.001) and lesion size <2 cm on mammography (OR, 0.45; 95% CI, 0.22-0.90; P = 0.021) and MRI (OR, 0.29; 95% CI, 0.09-0.94; P = 0.037) were less likely to be upgraded. No significant differences in performance were observed between logistic regression and machine learning models. Our results suggest that biopsy device, high nuclear grade, presence of suspicious axillary LN on US, and lesion size on mammography or MRI were independent predictors of DCIS underestimation.

7.
Ultrasound Q ; 38(1): 13-17, 2022 Jan 10.
Article in English | MEDLINE | ID: mdl-35001027

ABSTRACT

ABSTRACT: The purpose of our study was to evaluate the reproducibility of size measurement of breast lesions using automated breast ultrasonography (ABUS) compared with that with handheld ultrasonography (HHUS). Three breast radiologists performed HHUS and measured the lesions size in 2 different phantoms: lesions with various shape, size, and same stiffness (phantom 1) and lesions with same shape, size, and various stiffness (phantom 2). After 1 month, the same radiologists measured the lesion size of the same breast phantoms in the images obtained using ABUS. We evaluated interobserver variability between 3 radiologists in ABUS and HHUS, and intraobserver variability of radiologists between ABUS and HHUS. Intraclass correlation coefficient (ICC) was used in statistical analysis. The measured size of lesions on HHUS was slightly larger than that on ABUS in both phantom 1 and 2, although not statistically significant (P = 0.314, P = 0.858). There were no significant differences in size measurements between the radiologists' measurements and the reference size in phantom 2 (P = 0.862). The ICCs for the interobserver agreement between the 3 radiologists were 0.98 to 0.99 on ABUS and 0.99 to 1.00 on HHUS, respectively. The ICCs for the intraobserver agreement between ABUS and HHUS were 0.97 to 0.97 in phantom 1 and 0.98 to 0.99 in phantom 2. In conclusion, ABUS showed excellent interobserver and intraobserver agreement with HHUS in measuring size of the lesions, regardless of shape, size, and stiffness. Therefore, ABUS mixed with HHUS can be used reliably in following up breast lesions size.


Subject(s)
Breast Neoplasms , Ultrasonography, Mammary , Breast/diagnostic imaging , Breast Neoplasms/diagnostic imaging , Female , Humans , Reproducibility of Results , Sensitivity and Specificity , Ultrasonography , Ultrasonography, Mammary/methods
8.
Endocr J ; 69(1): 67-74, 2022 Jan 28.
Article in English | MEDLINE | ID: mdl-34408101

ABSTRACT

This study evaluated how to manage Bethesda category III (Bethesda III) (atypia of undetermined significance/follicular lesion of undetermined significance [AUS/FLUS]) thyroid nodules according to the Korean Thyroid Imaging Reporting and Data System (K-TIRADS) to reduce unnecessary surgeries. A total of 161 thyroid nodules diagnosed as Bethesda III underwent surgery from 2016 to 2019. Ultrasonography-guided fine-needle aspiration (US-FNA) or core needle biopsy (CNB) was used for repeat examination. K-TIRADS category was assigned to the thyroid nodules. The proportion of malignancy in Bethesda III nodules confirmed by surgery were significantly increased in proportion relative to K-TIRADS with 60.0% low suspicion, 88.2% intermediate suspicion, and 100% high suspicion nodules (p < 0.001). The proportion of malignancy in AUS and FLUS were significantly different (94.2% vs. 40.0% p = 0.003). The proportion of malignancy in AUS increased with K-TIRADS categories, but there was no difference in FLUS. All K-TIRADS high suspicion nodules were AUS as papillary carcinomas (99%), while 80% of FLUS nodules and 50% of follicular carcinomas showed K-TIRADS low suspicion. In 116 nodules with repeat FNA or CNB after initial Bethesda III results, the conclusive result rate was significantly increased in proportion to K-TIRADS with 58.3% low suspicion, 83.3% intermediate suspicion, and 88.8% high suspicion nodules (p = 0.015). K-TIRADS low suspicion nodules of Bethesda III nodules should be managed after risk-benefit consideration rather than immediate surgery or repeat examination. K-TIRADS for Bethesda III nodules can predict papillary carcinoma well, but not follicular carcinoma.


Subject(s)
Adenocarcinoma, Follicular , Thyroid Neoplasms , Thyroid Nodule , Adenocarcinoma, Follicular/diagnostic imaging , Adenocarcinoma, Follicular/pathology , Biopsy, Fine-Needle , Humans , Retrospective Studies , Risk Assessment , Thyroid Neoplasms/diagnostic imaging , Thyroid Neoplasms/pathology , Thyroid Nodule/diagnostic imaging , Thyroid Nodule/pathology
9.
J Breast Cancer ; 24(4): 377-388, 2021 Aug.
Article in English | MEDLINE | ID: mdl-34352936

ABSTRACT

PURPOSE: To evaluate the accuracy of magnetic resonance imaging (MRI)-guided breast biopsy. METHODS: We retrospectively reviewed the clinical data of 111 consecutive patients referred for MRI-guided breast biopsy after mammography and breast ultrasound between May 2009 and April 2019. After excluding 37 patients without follow-up images (> 2 years), 74 patients (74 lesions) were finally included. We reviewed the histologic results of MRI-guided biopsy and subsequent surgery, post-biopsy management, and breast cancer development during follow-up. We investigated the false-negative rate, ductal carcinoma in situ (DCIS) underestimation, atypical ductal hyperplasia (ADH) underestimation rate, and technical failure rate of MRI-guided biopsy. RESULTS: Among 74 scheduled MRI-guided biopsies, six were canceled because biopsy was deemed unnecessary, while three failed due to technical difficulties (technical failure rate: 3/68, 4.4%). MRI-guided biopsy was performed in 65 patients, of which 18 patients were diagnosed with malignant lesions, 46 with benign lesions, and one with ADH bordering on DCIS. Subsequent surgery (n = 27) showed DCIS underestimation in three cases (3/7, 43%), ADH underestimation in two cases (1/2, 50%), as well as seven concordant benign and 11 concordant malignant lesions. The overall false-negative rate was 4.3% (2/46). Thirty-eight out of 48 benign lesions were followed-up (median period, 5.8 years; interquartile range, 4.1 years) without subsequent surgery. Thirty-seven concordant benign lesions were stable (n = 27) or disappeared (n = 10); however, the size of one discordant benign lesion increased on follow-up MRI and it was diagnosed as DCIS after 1 year. CONCLUSION: MRI-guided biopsy is an accurate method for exclusion of malignancy with a very low false-negative rate.

10.
Radiology ; 299(1): 73-83, 2021 04.
Article in English | MEDLINE | ID: mdl-33620293

ABSTRACT

Background Data are limited regarding the performance of abbreviated screening breast MRI during consecutive years and the characteristics of breast cancers missed and detected with it. Purpose To assess the longitudinal diagnostic performance of abbreviated screening MRI and to determine whether the screening outcomes of abbreviated MRI differed between yearly time periods for 3 consecutive years. Materials and Methods This retrospective study included 1975 consecutive women who underwent abbreviated screening MRI between September 2015 and August 2018. Breast Imaging Reporting and Data System (BI-RADS) categories 3-5 defined positive results, and BI-RADS categories 1-2 defined negative results. Cancer detection rate (CDR), sensitivity, specificity, positive predictive value (PPV), abnormal interpretation rate (AIR), and interval cancer rate were assessed annually. Yearly performance measures were compared with the Fisher exact test by using the permutation method. Clinical-pathologic and imaging characteristics of the missed and detected cancers were compared by using the Fisher exact test and the Wilcoxon rank sum test. Results A total of 1975 women (median age, 49 years; interquartile range, 44-56 years) underwent 3037 abbreviated MRI examinations over 3 years. CDR (year 1 to year 3, 6.9-10.7 per 1000 examinations), positive predictive value for recall (9.7% [six of 62] to 15.6% [12 of 77]), positive predictive value for biopsy (31.6% [six of 19] to 63.2% [12 of 19]), sensitivity (75.0% [six of eight] to 80.0% [12 of 15]), and specificity (93.5% [807 of 863] to 94.1% [1041 of 1106]) were highest in year 3, and AIR (7.1% [62 of 871] to 6.9% [77 of 1121]) was lowest in year 3. However, all outcome measures did not differ statistically between years 1, 2, and 3 (all P > .05). The interval cancer rate was 0.66 per 1000 examinations (two of 3037). Thirty-eight breast cancers were identified in 36 women; 29 were detected with abbreviated MRI, but nine were missed. Of these, seven were detected with other imaging modalities after negative results at the last screening MRI examination, and two were interval cancers. All missed cancers were node-negative early-stage invasive cancers and were smaller (median size, 0.8 cm vs 1.2 cm; P = .01) than detected cancers. Conclusion Screening outcome measures of abbreviated MRI were sustained without significant differences between 3 consecutive years. All cancers missed at abbreviated MRI were node-negative invasive cancers and tended to be smaller than detected cancers. © RSNA, 2021 See also the editorial by Lee in this issue. Online supplemental material is available for this article.


Subject(s)
Breast Neoplasms/diagnostic imaging , Magnetic Resonance Imaging/methods , Mass Screening/methods , Adult , Breast Neoplasms/pathology , Early Detection of Cancer , Female , Humans , Middle Aged , Neoplasm Staging , Retrospective Studies
11.
Acta Radiol ; 62(4): 474-482, 2021 Apr.
Article in English | MEDLINE | ID: mdl-32493032

ABSTRACT

BACKGROUND: Few studies have categorized ultrasound (US) findings of various sized medullary thyroid carcinomas (MTCs) according to updated guidelines. PURPOSE: To evaluate and compare the differences in US findings of MTC according to nodule size, using the Korean Thyroid Imaging Reporting and Data System (K-TIRADS) and American Thyroid Association (ATA) guidelines. MATERIAL AND METHODS: The study included 119 patients with 129 MTC nodules, which were surgically confirmed at our institution between March 1999 and September 2017. Nodules were divided into large (≥1.0 cm) and small (<1.0 cm) groups. US images were analyzed according to the K-TIRADS and ATA guidelines. The differences in US characteristics between small and large nodules were compared using Fisher's exact or Chi-square tests. RESULTS: Of 129 MTC nodules, 84 (65.1%) were large nodules and 45 (34.9%) were small nodules. According to the nodule size, small MTC nodules were classified more commonly as high suspicion by K-TIRADS and ATA (95.6% and 93.3%, respectively) (P < 0.001), but presented neither cystic change, isoechogenicity, nor low suspicion category by K-TIRADS and ATA. In contrast, large MTC nodules showed more frequently cystic change (15.5%), isoechogenicity (16.7%), smooth margins (50%), or low or intermediate suspicion US features by K-TIRADS and ATA (59.6% and 36.0%, respectively) (all P values < 0.001). CONCLUSION: Most small MTC nodules are classified as high suspicion on US, whereas large MTC nodules are diagnosed more frequently as low or intermediate suspicion by K-TIRADS and ATA.


Subject(s)
Carcinoma, Neuroendocrine/diagnostic imaging , Carcinoma, Neuroendocrine/pathology , Thyroid Neoplasms/diagnostic imaging , Thyroid Neoplasms/pathology , Adolescent , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Practice Guidelines as Topic , Retrospective Studies , Tumor Burden , Ultrasonography , Young Adult
12.
Ultrasound Med Biol ; 47(1): 95-103, 2021 01.
Article in English | MEDLINE | ID: mdl-33097314

ABSTRACT

This study aimed to investigate the effect of calcifications on shear-wave elastography in evaluating breast lesions. We retrospectively reviewed ultrasound images of 673 breast lesions and compared the elasticity between lesions with and without calcifications in three subgroups: benign lesions, in situ carcinomas and invasive carcinomas. Breast lesions were confirmed histologically (n = 401) or by follow-up images for more than 2 y (n = 272). Calcifications were present in 25.3% (170/673) of the lesions. The Emean values with and without calcifications, respectively, were as follows: 62.8 and 29.8 kPa in benign lesions (p = 0.000), 114.6 and 52.8 kPa in in situ carcinomas (p = 0.037) and 171.9 and 146.4 kPa in invasive carcinomas (p = 0.018). The presence of calcifications significantly increased the Emean of breast lesions. Shear-wave elastography should be carefully interpreted in benign lesions with calcifications and in situ carcinomas without calcifications.


Subject(s)
Breast Diseases/complications , Breast Diseases/diagnostic imaging , Breast Neoplasms/complications , Breast Neoplasms/diagnostic imaging , Calcinosis/diagnostic imaging , Elasticity Imaging Techniques , Ultrasonography, Mammary/methods , Adult , Aged , Aged, 80 and over , Female , Humans , Middle Aged , Retrospective Studies , Young Adult
13.
Eur Radiol ; 31(3): 1693-1706, 2021 Mar.
Article in English | MEDLINE | ID: mdl-32888070

ABSTRACT

OBJECTIVE: To develop a classification system using imaging features to interpret breast non-mass lesions (NMLs) detected on US and to stratify their cancer risk. METHODS: This retrospective study included 715 patients with 715 breast NMLs detected on breast US from 2012 to 2016. Each patient underwent mammography at the time of diagnosis. Radiologists assessed US and mammographic features and final BI-RADS categories. Multivariable logistic regression was used to find imaging features associated with malignancy in a development dataset (n = 460). A system to classify BI-RADS categories (3 to 5) was developed based on the odds ratios (ORs) of imaging features significantly associated with malignancy and validated in a distinct validation dataset (n = 255). RESULTS: Among 715 NMLs, 385 (53.8%) were benign and 330 (46.2%) were malignant. In the development dataset, the following B-mode US features were associated with malignancy (all p < 0.001): segmental distribution (OR = 3.03; 95% confidence interval [CI], 1.50-6.15), associated calcifications (OR = 4.26; 95% CI, 1.62-11.18), abnormal ductal change (OR = 4.91; 95% CI, 2.07-11.68), and posterior shadowing (OR = 20.20; 95% CI, 6.46-63.23). The following mammographic features were also associated with malignancy (all p < 0.001): calcifications (OR = 7.98; 95% CI, 3.06-20.81) and focal asymmetry (OR = 4.75; 95% CI, 1.90-11.88). In the validation dataset, our classification system using US and mammography showed a higher area under the curve (0.951-0.956) compared to when it was not applied (0.908-0911) to predict malignancy with BI-RADS categories (p < 0.05). CONCLUSION: Our classification system which incorporates US and mammographic features of breast NMLs can help interpret and manage all NMLs detected on breast US by stratifying cancer risk according to BI-RADS categories. KEY POINTS: • When diagnosing breast NMLs detected on US, suspicious US features are segmental distribution, associated abnormal ductal change, calcifications, and posterior shadowing within or around the NML on B-mode US, while a probably benign US feature is the presence of multiple small cysts. • Corresponding suspicious mammographic features of breast NMLs detected on US are associated calcifications and focal asymmetry. • Our classification system which incorporates US features with and without mammography can potentially be used to interpret and manage any NMLs detected on breast US in clinical practice.


Subject(s)
Breast Neoplasms , Calcinosis , Breast/diagnostic imaging , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/epidemiology , Humans , Mammography , Retrospective Studies
14.
Medicine (Baltimore) ; 99(48): e23252, 2020 Nov 25.
Article in English | MEDLINE | ID: mdl-33235082

ABSTRACT

The role of histogram based on ultrasound (US) images for thyroid nodules found in fluorine-18 fluorodeoxyglucose (18F-FDG) Positron Emission Tomography/Computed Tomography (PET-CT) is unknown. We aimed to assess whether histogram analysis using gray scale US could differentiate thyroid nodules detected by PET-CT.In this study, 71 thyroid nodules ≥1 cm were identified in 71 patients by conducting 18F-FDG PET-CT, from January 2010 to June 2013. Subsequently, either grayscale US-guided fine needle aspirations or core needle biopsies were performed on each patient. Each grayscale US feature was categorized according to the Korean Thyroid Imaging Reporting and Data System (K-TIRADS). Histogram parameters (skewness, kurtosis, intensity, uniformity, and entropy) were extracted from the grayscale US images followed by statistical analysis using the Chi-Squared or Mann-Whitney U tests.The 71 nodules comprised 30 (42.3%) benign nodules, 30 (42.3%) primary thyroid malignancies, and 11 (15.4%) metastatic lesions. Tumor size, US findings, and histogram parameters were significantly different between the benign and malignant thyroid nodules (P = .011, P = .000, and P < .02, respectively). A comparison showed that parallel orientation and an absence of calcifications were found more frequently in metastatic thyroid nodules than in primary thyroid malignancies (P = .04, P < .000, respectively). However, histogram parameters and K-TIRADS were not significantly different between primary thyroid malignancies and metastatic lesions.There is a limit to replacing cytopathological confirmation with texture analysis for the differentiation of thyroid nodules detected by PET-CT. Therefore, cytopathological confirmation of nodules appearing malignant on US images cannot be avoided for an ultimate diagnosis of metastasis.


Subject(s)
Fluorodeoxyglucose F18/metabolism , Positron Emission Tomography Computed Tomography/methods , Thyroid Nodule/diagnostic imaging , Ultrasonography/methods , Adult , Aged , Aged, 80 and over , Biopsy, Fine-Needle/methods , Biopsy, Large-Core Needle/methods , Female , Humans , Male , Middle Aged , Neoplasm Metastasis/diagnostic imaging , Neoplasm Metastasis/pathology , Neoplasms/diagnostic imaging , Neoplasms/pathology , Retrospective Studies , Thyroid Gland/pathology , Thyroid Nodule/pathology
15.
Medicine (Baltimore) ; 99(16): e19676, 2020 Apr.
Article in English | MEDLINE | ID: mdl-32311941

ABSTRACT

RATIONALE AND OBJECTIVES: To evaluate the diagnostic performance of abbreviated screening breast magnetic resonance imaging (AB-MRI) for screening in women with previously treated breast cancer. MATERIALS AND METHODS: This retrospective study included consecutive AB-MRI from September 2015 to December 2016 in patients with previously treated breast cancer. Longitudinal medical record of patients' demographics, outcomes of imaging surveillance and results of biopsy was reviewed. Protocol consisted of T2-weighted scanning and dynamic contrast-enhanced imaging including one pre-contrast and two post-contrast scans. A positive examination was defined as final assessment of BI-RADS 4 or 5 and negative was defined as BI-RADS 1, 2, or 3. Abnormal interpretation rate, cancer detection rate (CDR), sensitivity, specificity, accuracy, positive predictive value (PPV), and negative predictive value (NPV) were analyzed. RESULTS: Among total 1043 AB-MRI, 29 (2.8%) AB-MRI had suspicious findings including 26 (2.5%) BI-RADS 4 and 3 (0.3%) BI-RADS 5 assessments. CDR was 9.59 per 1000. Performance outcomes were as follows: sensitivity, 71.4%; specificity, 98.2%; accuracy, 97.8%; PPV 1, 35.7%; PPV3 50%; and NPV 99.6%. Four cancers with false negative MRI were all early cancers of <1.0 cm with node negative. One was palpable interval cancer while the others were alternative screening modality-detected asymptomatic cancers before the next MRI screening. CONCLUSION: AB-MRI showed high accuracy and NPV for detecting cancer recurrence in women with previously treated breast cancer. Missed cancers were all minimal cancers with node negative.


Subject(s)
Breast Neoplasms/diagnostic imaging , Breast/diagnostic imaging , Early Detection of Cancer , Magnetic Resonance Imaging , Neoplasm Recurrence, Local/diagnostic imaging , Adult , Aged , Aged, 80 and over , Breast/surgery , Breast Neoplasms/surgery , Contrast Media , Early Detection of Cancer/methods , False Negative Reactions , Female , Humans , Longitudinal Studies , Magnetic Resonance Imaging/methods , Middle Aged , Retrospective Studies , Sensitivity and Specificity
16.
Sci Rep ; 10(1): 4969, 2020 03 18.
Article in English | MEDLINE | ID: mdl-32188891

ABSTRACT

Thyroid nodules are initially handled by fine needle aspiration (FNA). However, the stance of thyroid core needle biopsy (CNB) still is a challenge. This study aimed to compare the diagnostic performances and conclusive rates of FNA and CNB for the diagnosis of thyroid nodules and to define effective indications of CNB. This retrospective study enrolled 1,060 consecutive thyroid nodules in 1,037 patients who underwent FNA from January 2008 to May 2008, and 462 consecutive nodules in 453 patients who underwent CNB from January 2014 to December 2015 at our institution. Ultrasound (US) features were classified according to the American College of Radiology Thyroid Imaging Reporting and Data System (ACR TI-RADS) and Korean TIRADS (K-TIRADS). We compared diagnostic performances and conclusive rates between FNA and CNB groups. Propensity score matching was conducted to match FNA patients with CNB patients. After matching, the diagnostic performances for selecting surgical candidates and predicting malignancy were comparable between the two biopsy groups. Based on US findings, conclusive results were obtained significantly more in CNB than in FNA when thyroid nodules were classified as ACR TI-RADS or K-TIRADS category 4 and measured larger than 2 cm. Diagnostic performances between FNA and CNB were comparable. Superiority of CNB to FNA was found for thyroid nodules larger than 2 cm and classified as ACR TI-RADS or K-TIRADS category 4.


Subject(s)
Biopsy, Fine-Needle/methods , Biopsy, Large-Core Needle/methods , Thyroid Gland/pathology , Thyroid Neoplasms/diagnosis , Thyroid Nodule/diagnosis , Ultrasonography/methods , Female , Humans , Male , Middle Aged , Propensity Score , Retrospective Studies , Thyroid Gland/diagnostic imaging , Thyroid Neoplasms/classification , Thyroid Neoplasms/diagnostic imaging , Thyroid Nodule/classification , Thyroid Nodule/diagnostic imaging
17.
Korean J Radiol ; 21(3): 377-383, 2020 03.
Article in English | MEDLINE | ID: mdl-32090530

ABSTRACT

OBJECTIVE: The purpose of this study was to evaluate a novel radiofrequency ablation (RFA) application utilizing an adjustable electrode for treatment of benign thyroid nodules. MATERIALS AND METHODS: From April 2011 to December 2018, 21 patients underwent RFA treatment on 21 thyroid nodules, utilizing an 18-gauge internally cooled electrode equipped with a size adjustable active tip. The peripheral nodule portions were ablated with the moving-shot technique and a shorter active tip, and the nodule centers were ablated with the fixed technique and a longer active tip. We assessed parameters including characteristics of the treated nodules, use of variablesized active tips, volume reduction rate, therapeutic success rate, and post-procedural complications. The therapeutic success rate was defined as a > 50% volume reduction of the initial nodule volume at the 6- or 12-month follow-up. RESULTS: The treated thyroid nodules were large enough to cause symptoms (mean volume, 29.6 mL). Two types of active tips per session were used for all nodules. The mean volume reduction rate at the last follow-up was 68.3 ± 4.4% and our therapeutic success rate was 90.5%. Both symptoms and cosmetic scores decreased significantly. Minor complications in three patients were recorded during and after the procedure. CONCLUSION: This initial study demonstrated that an adjustable electrode for RFA of benign thyroid nodules effectively and safely resulted in volume reduction.


Subject(s)
Catheter Ablation/methods , Thyroid Nodule/surgery , Adult , Aged , Catheter Ablation/instrumentation , Electrodes , Feasibility Studies , Female , Follow-Up Studies , Humans , Male , Middle Aged , Retrospective Studies , Thyroid Nodule/diagnostic imaging , Ultrasonography
18.
Clin Endocrinol (Oxf) ; 92(5): 468-474, 2020 05.
Article in English | MEDLINE | ID: mdl-32012326

ABSTRACT

OBJECTIVE: We evaluated the preoperative diagnostic values of ultrasound (US), fine-needle aspiration (FNA) and core needle biopsy (CNB) leading to surgery in patients with FTC. METHODS: From October 1994 to July 2016, 298 patients with FTC who had preoperative US images and underwent US-guided FNA or CNB and surgery were included in this study. We evaluated the results of preoperative FNA or CNB based on the Bethesda system and the US findings according to the Korean thyroid imaging reporting and data system (K-TIRADS). RESULTS: Predominant US features of FTC showed solid, hypo- or iso-echogenicity, oval smooth margin and halo with no calcification. Based on K-TIRADS, 140 (47.0%) patients with FTC were categorized as low suspicion, 133 (44.63%) as intermediate suspicion and 25 (8.4%) as high suspicion at US. Considering only FNA cytology (n = 230), 6.9% were revealed as Bethesda class I, 16.1% as class II, 37.0% as class III, 29.1% as class IV and 10.9% as class V. Considering the 68 cases with CNB results, 2.9% were revealed as class I, 4.4% as class II, 20.6% as class III and 72.1% as class IV. Despite multiple FNAs, 16.7% of the 84 patients with FTC still obtained Bethesda class I or class II. CNB results in patients with FTC had a significantly higher rate of Bethesda class IV compared to the FNA results (P < .001). FTCs with distant metastasis exhibited a significantly higher rate of Bethesda classes IV and V compared to those without distant metastasis (P = .004). CONCLUSION: Surgery for FTC is deferred only with preoperative US and FNA. CNB in patients with FTC can lead to surgery better than FNA. Therefore, if the US feature is characteristic and a serially growing large nodule is suspected, the first attempt of CNB may be helpful in selecting a surgical candidate.


Subject(s)
Adenocarcinoma, Follicular , Thyroid Neoplasms , Thyroid Nodule , Adenocarcinoma, Follicular/diagnostic imaging , Biopsy, Fine-Needle , Biopsy, Large-Core Needle , Humans , Retrospective Studies , Thyroid Neoplasms/diagnostic imaging , Ultrasonography , Ultrasonography, Interventional
19.
Br J Radiol ; 93(1106): 20190733, 2020 Feb 01.
Article in English | MEDLINE | ID: mdl-31868524

ABSTRACT

OBJECTIVE: To compare the diagnostic performance of breast MRI with abbreviated protocol (AB-MRI) and full ddiagnostic protocol (FDP-MRI) for surveillance of females with a personal history of breast cancer. METHODS: In this retrospective study, we analyzed the outcomes of total 1312 post-operative screening breast MRI matched from 1045 AB-MRI and 677 FDP-MRI, which had histologic confirmation for suspicious MRI findings or 1 year negative follow-up images. This study was approved by the institutional review board and informed patient consent was waved. AB-MRI consists of T2 weighted scanning and dynamic contrast-enhanced imaging including one pre-contrast and two post-contrast scans. We compared the diagnostic performance for recurrent breast cancer in terms of sensitivity, specificity, positive-predictive value, negative-predictive value, and accuracy and area under the curve between the screening AB-MRI and FDP-MRI. RESULTS: Overall, 13 recurrent tumors among 1312 post-operative cases screened with breast MRI (1.0%) were detected including 8 invasive cancer, 2 cases of in situ cancer, and 3 cases of metastatic lymph nodes. The sensitivity and negative predictive value were 70 vs 100 and 99.5% vs 100% in AB-MRI and FDP-MRI. Specificity, positive predictive value, accuracy, and area under the curve of AB-MRI and FDP-MRI were 98.0% vs 96.9%, 35.0% vs 23.1%, 97.6% vs 97.0%, and 0.840 vs 0.985, respectively. CONCLUSION: The performance of AB-MRI was comparable to that of FDP-MRI in detecting recurrent breast cancer and decreased false positive cases. ADVANCES IN KNOWLEDGE: AB-MRI provides a reliable alternative with similar diagnostic performance and shorter MRI acquisition time.


Subject(s)
Breast Neoplasms/diagnosis , Clinical Protocols , Early Detection of Cancer , Female , Humans , Magnetic Resonance Imaging/methods , Middle Aged , Neoplasm Recurrence, Local/diagnosis , Postoperative Care , Retrospective Studies , Risk Factors
20.
Korean J Radiol ; 20(10): 1454-1461, 2019 10.
Article in English | MEDLINE | ID: mdl-31544370

ABSTRACT

OBJECTIVE: To retrospectively compare the diagnostic performances of two different ultrasound (US)-guided core needle biopsy (CNB) techniques for intermediate or low suspicion thyroid nodules. MATERIALS AND METHODS: Between August 2015 and December 2016, two different biopsy techniques were alternatively applied for 248 consecutive thyroid nodules, of which, 140 intermediate or low suspicion thyroid nodules were included in this study. In the first technique, two specimens included nodular tissue, nodular margin, and surrounding normal parenchyma (i.e., marginal target). In the second technique, two specimens were obtained from two different target areas, one for the marginal target and another for the intranodular target. The diagnostic performances of the two techniques to predict neoplasm and malignancy were compared. RESULTS: CNB was performed on 80 intermediate or low suspicion nodules (57.1%) using the first technique and on 60 (42.9%) using the second technique. The accuracy of the first technique for predicting neoplasm or malignancy was significantly higher than that of the second technique (100% vs. 93.3%, p = 0.032 for predicting neoplasm; 88.8% vs. 75.0%, p = 0.033 for predicting malignancy). The negative predictive value of the first technique for predicting malignancy was also significantly higher than that of the second technique (87.5% vs. 72.7%, p = 0.035). CONCLUSION: For intermediate or low suspicion thyroid nodules, US-guided CNB to obtain two specimens with marginal targets is more effective for diagnosing neoplasm or malignancy than is CNB for respective marginal and intranodular targets.


Subject(s)
Biopsy, Large-Core Needle/methods , Image-Guided Biopsy/methods , Thyroid Neoplasms/diagnosis , Thyroid Nodule/diagnosis , Ultrasonography/methods , Adult , Female , Humans , Male , Middle Aged , Retrospective Studies , Thyroid Neoplasms/pathology , Thyroid Nodule/pathology
SELECTION OF CITATIONS
SEARCH DETAIL
...