Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 33
Filter
Add more filters










Publication year range
1.
Anal Chem ; 96(16): 6501-6510, 2024 Apr 23.
Article in English | MEDLINE | ID: mdl-38593185

ABSTRACT

Here, we integrated two key technologies within a microfluidic system, an electrokinetic preconcentration of analytes by ion Concentration Polarization (CP) and local electrochemical sensors to detect the analytes, which can synergistically act to significantly enhance the detection signal. This synergistic combination, offering both decoupled and coupled operation modes for continuous monitoring, was validated by the intensified fluorescent intensities of CP-preconcentrated analytes and the associated enhanced electrochemical response using differential pulse voltammetry and chronoamperometry. The system performance was evaluated by varying the location of the active electrochemical sensor, target analyte concentrations, and electrolyte concentration using fluorescein molecules as the model analyte and Homovanillic acid (HVA) as the target bioanalyte within both phosphate-buffered saline (PBS) and artificial sweat solution. The combination of on-chip electrochemical sensing with CP-based preconcentration renders this generic approach adaptable to various analytes. This advanced system shows remarkable promise for enhancing biosensing detection in practical applications while bridging the gap between fundamental research and practical implementation.

2.
Vet Q ; 44(1): 1-7, 2024 Dec.
Article in English | MEDLINE | ID: mdl-38497337

ABSTRACT

Pancreatic alpha amylase (P-AMY) is used as a biomarker of acute pancreatitis (AP) in human medicine. To our knowledge, there are no studies evaluating the usefulness of P-AMY in dogs with AP. In this study, we evaluated the diagnostic value of P-AMY, currently not verified in veterinary medicine. The AP group (n = 40) consisted of dogs with AP diagnosed using clinical signs and laboratory examinations, including abnormal canine pancreatic lipase (cPL) concentration, and compatible abdominal ultrasound examination at first presentation. Evaluation of the canine AP severity (CAPS) score was performed. The control group (n = 38) was composed of normal dogs without any abnormalities in clinical findings, blood exams or diagnostic imaging. The correlation of P-AMY with cPL was confirmed by Pearson's correlation analysis (r = 0.564, p < .001). The sensitivity and specificity for the most appropriate cut-off values of P-AMY were recorded similar to the values of DGGR. The dogs with AP and CAPS ≥11 had significantly higher serum P-AMY (p = .016) contrary to DGGR lipase and cPL. Furthermore, there was a significant difference in the median P-AMY dependent on the presence of systemic inflammatory response syndrome (p = .001). P-AMY showed similar level of diagnostic accuracy along with sensitivity and specificity compared to DGGR lipase. In addition, P-AMY showed a significant association with CAPS score, contrary to cPL and DGGR lipase. Along with other biomarkers associated with AP, P-AMY has the potential of usefulness as a supportive diagnostic and prognostic biomarker of AP in dogs.


Subject(s)
Dog Diseases , Pancreatitis , Dogs , Animals , Humans , Pancreatitis/diagnosis , Pancreatitis/veterinary , Pilot Projects , Pancreatic alpha-Amylases , Acute Disease , Dog Diseases/diagnostic imaging , Lipase , Biomarkers
3.
J Vet Intern Med ; 38(1): 41-50, 2024.
Article in English | MEDLINE | ID: mdl-38064361

ABSTRACT

BACKGROUND: Hypomagnesemia is associated with a poor prognosis in humans with congestive heart failure (CHF), but studies in veterinary medicine are limited. HYPOTHESIS: Serum ionized magnesium concentration [iMg2+ ] would decrease as CHF progresses compared with the initial diagnostic levels and that lower [iMg2+ ] would be negatively associated with prognosis in dogs with CHF. ANIMALS: A total of 181 client-owned dogs with myxomatous mitral valve disease (MMVD) were included. They were classified into the preclinical stage (NO-CHF, n = 108), stage C (n = 42), and stage D (n = 31) based on the American College of Veterinary Internal Medicine MMVD classification. METHODS: This is a retrospective study from 2 referral centers. The [iMg2+ ] was compared among the NO-CHF, stage C, and stage D groups. Kaplan-Meier curves and the log-rank test were used to compare the incidence of death between groups. Multivariable Cox regression analysis was used to estimate the association of hypomagnesemia with the death. RESULTS: In the stage D group, the [iMg2+ ] was lower than that in the NO-CHF (P < .0001) and stage C groups (P < .003). In the Kaplan-Meier survival analysis, the 1-year cumulative survival rate in hypomagnesemic dogs was 53% compared with 91.5% in normomagnesemic dogs (log-rank test, P < .0001). In the multivariable Cox analysis, lower concentration of [K+ ] and [iMg2+ ], along with higher Evel , were associated with negative prognoses. Specifically, hypomagnesemia was associated with an approximately 4-fold increased risk of death (hazard ratio = 4.015; 95% confidence interval, 1.537-10.488; P = .005). CONCLUSIONS AND CLINICAL IMPORTANCE: Assessing the [iMg2+ ] might serve as a potential marker for estimating the severity and prognosis indirectly in dogs with MMVD. Combining [iMg2+ ] measurement with other diagnostic methods, such as echocardiography, could improve the prognostic evaluation of MMVD in dogs.


Subject(s)
Dog Diseases , Heart Failure , Heart Valve Diseases , Humans , Dogs , Animals , Mitral Valve , Magnesium , Retrospective Studies , Clinical Relevance , Heart Valve Diseases/veterinary , Heart Failure/complications , Heart Failure/veterinary
4.
Front Vet Sci ; 10: 1142418, 2023.
Article in English | MEDLINE | ID: mdl-37519993

ABSTRACT

Introduction: Adrenocortical carcinoma (ACC) with metastasis has a grave prognosis, and adrenalectomy is associated with a high perioperative mortality rate in dogs. A favorable outcome following trilostane treatment in patients with metastatic ACC confirmed by a decreased size of the adrenal tumor and metastatic lesions has not been reported in dogs. Case description: A 12-year-old neutered male Maltese dog was diagnosed with a right adrenal tumor and a hepatic mass. Adrenal-dependent hyperadrenocorticism (ADH) was diagnosed based on clinical signs and an adrenocorticotropic hormone stimulation test (ACTHST). In addition, tests for plasma metanephrine and normetanephrine ruled out a pheochromocytoma. Based on cytology and computed tomography, unresectable metastatic ACC was confirmed. The dog was managed with trilostane due to the presence of distant metastasis. Medical management improved the clinical signs and post-ACTHST cortisol concentrations. One year after the first presentation, the clinical signs and ACTHST test showed a favorable outcome. In addition, computed tomography revealed a decreased size of the right adrenal tumor and resolution of the hepatic mass. Conclusions: Trilostane could be considered as a treatment option for unresectable metastatic ACC. A decrease in tumor size following treatment with trilostane has not been reported in dogs. This case report is the first to demonstrate a favorable outcome of metastatic ACC following trilostane mono therapy for >1 year.

5.
Front Vet Sci ; 10: 1142535, 2023.
Article in English | MEDLINE | ID: mdl-37292428

ABSTRACT

Introduction: Prealbumin (PAB) is a plasma protein synthesized in the hepatic parenchymal cells. PAB has a short half-life (~2 days), and its concentration is affected by changes in transcapillary escape. Measurement of PAB is widely used in hospitalized patients in human medicine due to its decreasing concentration in states of inflammation and malnutrition. However, only a few studies are available in dogs. The aim of this study is to determine whether the plasma PAB concentration decreases in dogs with inflammation and to evaluate the relationship between the plasma PAB concentration and inflammation-related parameters in dogs. Methods: A total of 94 dogs were divided into healthy (n = 33) and diseased (n = 61) groups. These were further divided into group A (n = 24) and group B (n = 37) according to plasma C-reactive protein (CRP) levels. Group A included dogs with a plasma CRP < 10 mg/L, and group B consisted of dogs with a plasma CRP ≥ 10 mg/L. Patient signalment, history, physical examination findings, hematologic and biochemical parameters, various inflammatory markers, and plasma PAB levels were investigated and compared between groups. Results: The plasma PAB concentration was found to be lower in group B than in the other groups (p < 0.001), but no statistical difference was found when comparing the control group and group A (p > 0.05). A plasma PAB < 6.3 mg/dL predicted an increased CRP level (10 mg/L or greater) with a sensitivity of 89.5% and a specificity of 86.5%. Receiver operating characteristic curve analysis revealed that the area under the curve for PAB was higher than that for the white blood cell count, neutrophil count, albumin level, lactate level, neutrophil-to-lymphocyte ratio, and neutrophil percentage-to-albumin ratio. In addition, the PAB concentration was significantly negatively correlated with the CRP concentration (r = -0.670, p < 0.001). Conclusion: In conclusion, this is the first study to demonstrate the clinical usefulness of the plasma PAB concentration as an inflammatory marker in dogs. These findings suggest that measuring the plasma PAB concentration along with the CRP concentration may be more useful for evaluating inflammation than measuring CRP alone in canine patients.

6.
Anal Chem ; 95(16): 6514-6522, 2023 Apr 25.
Article in English | MEDLINE | ID: mdl-37039317

ABSTRACT

Microfluidic channels with an embedded ion permselective medium under the application of electric current are commonly used for electrokinetic processes as on-chip ion concentration polarization (ICP) and bioparticle preconcentration to enhance biosensing. Herein, we demonstrate the ability to dynamically control the electrically driven ion transport by integrating individually addressable microvalves. The microvalves are located along a main microchannel that is uniformly coated with a thin layer of an ion-exchange membrane (IEM). The interplay of ionic transport between the solution within the microchannel and the thin IEM, under an applied electric current, can be locally tuned by the deformation of the microvalve. This tunability provides a robust and simple means of implementing new functionalities into lab-on-a-chip devices, e.g., dynamic control over multiple ICP layers and their associated preconcentrated molecule plugs, multiplex sensing, suppression of biofouling, and plug dispersion, while maintaining the well-known application of microvalves as steric filtration.

7.
ACS Appl Mater Interfaces ; 14(13): 15765-15773, 2022 Apr 06.
Article in English | MEDLINE | ID: mdl-35322665

ABSTRACT

In this work, we present dielectrophoresis (DEP) and in situ electrorotation (ROT) characterization of reversibly stimuli-responsive "dynamic" microcapsules that change the physicochemical properties of their shells under varying pH conditions and can encapsulate and release (macro)molecular cargo on demand. Specifically, these capsules are engineered to open (close) their shell under high (low) pH conditions and thus to release (retain) their encapsulated load or to capture and trap (macro)molecular samples from their environment. We show that the steady-state DEP and ROT spectra of these capsules can be modeled using a single-shell model and that the conductivity of their shells is influenced most by the pH. Furthermore, we measured the transient response of the angular velocity of the capsules under rotating electric field conditions, which allows us to directly determine the characteristic time scales of the underlying physical processes. In addition, we demonstrate the magnetic manipulation of microcapsules with embedded magnetic nanoparticles for lab-on-chip tasks such as encapsulation and release at designated locations and the in situ determination of their physicochemical state using on-chip ROT. The insight gained will enable the advanced design and operation of these dynamic drug delivery and smart lab-on-chip transport systems.

8.
Lab Chip ; 22(4): 814-825, 2022 02 15.
Article in English | MEDLINE | ID: mdl-35080550

ABSTRACT

Herein, we demonstrate digital microfluidics-like manipulations of preconcentrated biomolecule plugs within a continuous flow that is different from the commonly known digital microfluidics involving discrete (i.e. droplets) media. This is realized using one- and two-dimensional arrays of individually addressable ion-permselective membranes with interconnecting microfluidic channels. The location of powered electrodes, dictates which of the membranes are active and generates either enrichment/depletion diffusion layers, which, in turn, control the location of the preconcentrated plug. An array of such powered membranes enables formation of multiple preconcentrated plugs of the same biosample as well as of preconcentrated plugs of multiple biosample types introduced via different inlets in a selective manner. Moreover, digital-microfluidics operations such as up-down and left-right translation, merging, and splitting, can be realized, but on preconcentrated biomolecule plugs instead of on discrete droplets. This technology, based on nanoscale electrokinetics of ion transport through permselective medium, opens future opportunities for smart and programmable digital-like manipulations of preconcentrated biological particle plugs for various on-chip biological applications.


Subject(s)
Microfluidic Analytical Techniques , Microfluidics , Electrodes
9.
J Colloid Interface Sci ; 588: 611-618, 2021 Apr 15.
Article in English | MEDLINE | ID: mdl-33303245

ABSTRACT

The use of active particles for cargo transport offers unique potential for applications ranging from targeted drug delivery to lab-on-a-particle systems. Previously, deployment of metallo-dielectric Janus spherical particles (JPs) as mobile microelectrodes for transport and dielectrophoretic manipulation of cargo has been shown to be singularly controlled via an applied electric field. Herein, we extended this to a metallo-dielectric pollen featuring multiple dielectrophoretic traps associated with its many spikes, and characterized its loading capacities for various cargo sizes and frequencies. When compared to spherical JPs, the active pollen exhibited a significantly enhanced cargo loading capacity due to its multiple dielectrophoretic traps. These findings open new opportunities for application of bio-hybrid particles with diverse and irregular shapes, such as pollen, as efficient cargo carriers, local electroporation and targeted drug delivery.

10.
Nano Lett ; 20(12): 8524-8533, 2020 12 09.
Article in English | MEDLINE | ID: mdl-33226817

ABSTRACT

Integration of ionic permselective medium (e.g., nanochannels, membranes) within microfluidic channels has been shown to enable on-chip desalination, sample purification, bioparticle sorting, and biomolecule concentration for enhanced detection sensitivity. However, the ion-permselective mediums are generally of fixed properties and cannot be dynamically tuned. Here we study a microfluidic device consisting of an array of individually addressable elastic membranes connected in series on top of a single microfluidic channel that can be deformed to locally reduce the channel cross-section into a nanochannel. Dynamic tunability of the ion-permselective medium, as well as controllability of its location and ionic permselectivity, introduces a new functionality to microfluidics-based lab-on-a-chip devices, for example, dynamic localization of preconcentrated biomolecule plugs at different sensing regions for multiplex detection. Moreover, the ability to simultaneously form a series of preconcentrated plugs at desired locations increases parallelization of the system and the trapping efficiency of target analytes.

11.
Nanoscale ; 12(46): 23586-23595, 2020 Dec 08.
Article in English | MEDLINE | ID: mdl-33210690

ABSTRACT

Ionic concentration-polarization (CP)-based biomolecule preconcentration is an established method for enhancing the detection sensitivity of target biomolecules. However, the formed preconcentrated biomolecule plug rapidly sweeps over the surface-immobilized antibodies, resulting in a short-term overlap between the capture agent and the analyte, and subsequently suboptimal binding. To overcome this, we designed a setup allowing for the periodic formation of a preconcentrated biomolecule plug by activating the CP for predetermined on/off intervals. This work demonstrated the feasibility of cyclic CP actuation and optimized the sweeping conditions required to obtain the maximum retention time of a preconcentrated plug over a desired sensing region and enhanced detection sensitivity. The ability of this method to efficiently preconcentrate different analytes and to successfully increase immunoassay sensitivity underscore its potential in immunoassays serving the clinical and food testing industries.


Subject(s)
Antibodies, Immobilized , Biosensing Techniques , Immunoassay , Ions
12.
ACS Sens ; 5(4): 936-942, 2020 04 24.
Article in English | MEDLINE | ID: mdl-32141739

ABSTRACT

Previous micromotor-based biosensing studies used to functionalize the surface of the micromotor with specific molecular probes for binding of target analyte, thus limiting the use of the micromotor for the specific target. In contrast, here, we introduce a novel approach of using a nonfunctionalized micromotor as a generic cargo carrier being able to perform label-free and dynamic loading, transport, and release of functionalized beads. Hence, such an approach enables one to use the same micromotor system for sensing of varying targets via different commercially available functionalized beads, demonstrating the use of micromotors as a practical and versatile means for biosensing. We have also introduced a simplified microfluidic design that can be used for immunosensing or DNA binding tests without necessity for complicated fluid handling (buffer exchange, washing, etc.) steps. We expect this approach to open up new realizations of simplified and generic biosensing platforms.


Subject(s)
Biosensing Techniques/methods , Microfluidic Analytical Techniques/methods
13.
Anal Chem ; 92(3): 2476-2482, 2020 02 04.
Article in English | MEDLINE | ID: mdl-31880149

ABSTRACT

Concentration-polarization (CP)-based biomolecule preconcentration is highly effective in enhancing the detection sensitivity yet fails to precisely and dynamically control the location of the preconcentrated biomolecule plug to ensure overlap with the sensing region (e.g., immobilized molecular probes). Here, we used electrothermal (ET) stirring as a means of controlling the location of a preconcentrated biomolecule plug. The applied microfluidic device consisted of a Nafion membrane to induce the CP and an array of individually addressable microscale heaters for active local ET stirring. The experimental results demonstrated that such a novel platform enabled active control of the location of the preconcentrated plug of target biomolecules, ensuring its overlap with the functionalized microparticles and ultimately yielding enhanced detection sensitivity and binding kinetics. This was demonstrated using avidin-biotin particles as a simple bead-based bioassay model.


Subject(s)
Avidin/analysis , Biotin/analysis , Lab-On-A-Chip Devices , Temperature
14.
ACS Sens ; 4(7): 1806-1815, 2019 07 26.
Article in English | MEDLINE | ID: mdl-31204472

ABSTRACT

Presented is a novel flow sensor based on electrochemical sensing of the ionic concentration-polarization (CP) layer developed within a microchannel-ion permselective membrane device. To demonstrate the working principle of the electrochemical flow sensor, the effect of advection on the transient and steady-state ionic concentration-polarization (CP) phenomenon in microchannel-Nafion membrane systems is studied. In particular, we focused on the local impedance, measured using an array of electrode pairs embedded at the bottom of the microchannel, as well as the total current across the permselective medium, as two approaches for estimating the flow. We examined both a stepwise application of CP under steady-state flow and a stepwise application of flow under steady-state CP.


Subject(s)
Electrochemical Techniques/methods , Microfluidic Analytical Techniques/methods , Movement , Convection , Diffusion , Electric Conductivity , Electrochemical Techniques/instrumentation , Electrodes , Equipment Design , Humans , Insulin, Regular, Human/chemistry , Lab-On-A-Chip Devices , Microfluidic Analytical Techniques/instrumentation , Potassium Chloride/chemistry
15.
Nanoscale ; 11(19): 9436-9443, 2019 May 16.
Article in English | MEDLINE | ID: mdl-31038504

ABSTRACT

Ionic concentration-polarization (CP)-based biomolecule preconcentration is an established method for enhancing the detection sensitivity of a target biomolecule immunoassay. However, its main drawback lies in its inability to directly control the spatial overlap between the preconcentrated plug of biomolecules and the surface immobilized antibodies. To overcome this, we simultaneously preconcentrated freely suspended, surface functionalized nanoparticles and target molecules along the edge of a depletion layer, thus, increasing the binding kinetics and avoiding the need to tune their relative locations to ensure their spatial overlap. After the desired incubation time, the nanoparticles were dielectrophoretically trapped for postprocessing analysis of the binding signal. This novel combination of CP-based preconcentration and dielectrophoresis (DEP) was demonstrated through binding of avidin and biotin-conjugated particles as a model bead-based immunoassay, wherein increased detection sensitivity was demonstrated compared to an immunoassay without CP-based preconcentration. The DEP trapping of the beads following binding is important not only for an enhanced detection signal due to the preconcentration of the beads at the electrode edges but also for controlling their location for future applications integrating localized sensors. In addition, DEP may be important also as a preprocessing step for controlling the number of beads participating in the immunoassay.


Subject(s)
Immunoassay/methods , Antibodies, Immobilized/chemistry , Antibodies, Immobilized/immunology , Avidin/chemistry , Avidin/metabolism , Biotin/chemistry , Biotin/metabolism , Nanoparticles/chemistry , Time-Lapse Imaging
16.
Electrophoresis ; 40(11): 1606-1614, 2019 06.
Article in English | MEDLINE | ID: mdl-30892707

ABSTRACT

Often, in semen samples with minute amounts of sperm, even the single spermatozoon required to fertilize an oocyte cannot be found in the ejaculate. This is primarily because currently, sperm is generally searched for manually under a microscope. In this study, dielectrophoresis (DEP) was investigated as an alternative automated technique for sorting sperm cells. Using a quadrupolar electrode array it was shown that the head and tail of the sperm had independent and unique crossover frequencies corresponding to the transition of the DEP force from repulsive (negative) to attractive (positive). These surprising results were further analyzed, showing that the head and tail have their own distinct electrical properties. This significant result allows for the sperm's head, which contains the DNA, to be distanced from potentially damaging high electric fields using negative DEP while simultaneously manipulating and sorting the sperm using the positive DEP response of the tail. A proof of concept sorting chip was designed and tested. The low crossover frequency of the tail also allows for the use of a higher conductivity, and thus more physiological, medium than the conventional DEP solutions. Although more research is required to design and optimize an efficient, user-friendly, and high-throughput device, this research is a proof of concept that DEP has the potential to automate and improve the processing of semen samples, especially those containing only rare spermatozoa.


Subject(s)
Electrophoresis/methods , Spermatozoa/cytology , Animals , DNA , Electricity/adverse effects , Humans , Male , Proof of Concept Study , Sperm Head , Sperm Tail
17.
Nanoscale ; 10(24): 11633-11641, 2018 Jun 21.
Article in English | MEDLINE | ID: mdl-29896609

ABSTRACT

The ability to induce regions of high and low ionic concentrations adjacent to a permselective membrane or a nanochannel subject to an externally applied electric field (a phenomenon termed concentration-polarization) has been used for a broad spectrum of applications ranging from on-chip desalination, bacteria filtration to biomolecule preconcentration. But these applications have been limited by the ability to control the length of the diffusion layer that is commonly indirectly prescribed by the fixed geometric and surface properties of a nanofluidic system. Here, we demonstrate that the depletion layer can be dynamically varied by inducing controlled electrothermal flow driven by the interaction of temperature gradients with the applied electric field. To this end, a series of microscale heaters, which can be individually activated on demand are embedded at the bottom of the microchannel and the relationship between their activation and ionic concentration is characterized. Such spatio-temporal control of the diffusion layer can be used to enhance on-chip electro-dialysis by producing shorter depletion layers, to dynamically reduce the microchannel resistance relative to that of the nanochannel for nanochannel based (bio)sensing, to generate current rectification reminiscent of a diode like behavior and control the location of the preconcentrated plug of analytes or the interface of brine and desalted streams.

18.
Phys Rev E ; 97(4-1): 043104, 2018 Apr.
Article in English | MEDLINE | ID: mdl-29758647

ABSTRACT

We report evidence of variation in ion selectivity of a fabricated microchannel-nanochannel device resulting in the appearance of a distinct local maximum in the overlimiting chronopotentiometric response. In this system consisting of shallow microchannels joined by a nanochannel, viscous shear at the microchannel walls suppresses the electro-osmotic instability and prevents any associated contribution to the nonmonotonic response. Thus, this response is primarily electrodiffusive. Numerical simulations indicate that concentration polarization develops not only within the microchannel but also within the nanochannel itself, with a local voltage maximum in the chronopotentiometric response correlated with interfacial depletion and having the classic i^{-2} Sands time dependence. Furthermore, the occurrence of the local maxima is correlated with the change in selectivity due to internal concentration polarization. Understanding the transient nonideal permselective response is essential for obtaining fundamental insight and for optimizing efficient operation of practical fabricated nanofluidic and membrane devices.

19.
Phys Rev E ; 96(2-1): 023104, 2017 Aug.
Article in English | MEDLINE | ID: mdl-28950496

ABSTRACT

Here, we studied the effect of advection on the transient ion concentration-polarization phenomenon in microchannel-membrane systems. Specifically, the temporal evolution of the depletion layer in a system that supports net flow rates with varying Péclet values was examined. Experiments complemented with simplified analytical one-dimensional semi-infinite modeling and numerical simulations demonstrated either suppression or enhancement of the depletion layer propagation against or with the direction of the net flow, respectively. Of particular interest was the third-species fluorescent dye ion concentration-polarization dynamics which was further explained using two-dimensional numerical simulations that accounted for the device complex geometry.

20.
Sci Rep ; 7(1): 9010, 2017 08 21.
Article in English | MEDLINE | ID: mdl-28827642

ABSTRACT

Myxozoa is a diverse, speciose group of microscopic parasites, recently placed within the phylum Cnidaria. Myxozoans are highly reduced in size and complexity relative to free-living cnidarians, yet they have retained specialized organelles known as polar capsules, akin to the nematocyst stinging capsules of free-living species. Whereas in free-living cnidarians the stinging capsules are used for prey capture or defense, in myxozoans they have the essential function of initiating the host infection process. To explore the evolutionary adaptation of polar capsules to parasitism, we used as a model organism Ceratonova shasta, which causes lethal disease in salmonids. Here, we report the first isolation of C. shasta myxospore polar capsules using a tailored dielectrophoresis-based microfluidic chip. Using electron microscopy and functional analysis we demonstrated that C. shasta tubules have no openings and are likely used to anchor the spore to the host. Proteomic analysis of C. shasta polar capsules suggested that they have retained typical structural and housekeeping proteins found in nematocysts of jellyfish, sea anemones and Hydra, but have lost the most important functional group in nematocysts, namely toxins. Our findings support the hypothesis that polar capsules and nematocysts are homologous organelles, which have adapted to their distinct functions.


Subject(s)
Adaptation, Biological , Myxozoa/chemistry , Organelles/chemistry , Proteome/analysis , Protozoan Proteins/analysis , Animals , Microscopy, Electron , Myxozoa/ultrastructure , Organelles/ultrastructure , Proteomics
SELECTION OF CITATIONS
SEARCH DETAIL
...