1.
Electrophoresis ; 39(7): 998-1005, 2018 04.
Article in English | MEDLINE | ID: mdl-29330871

ABSTRACT

In the first part of this publication, the results from an international study evaluating the precision (i.e., repeatability and reproducibility) of N-glycosylation analysis using capillary electrophoresis of APTS-labeled N-glycans were presented. The corresponding results from ultra-high performance liquid chromatography (UHPLC) with fluorescence detection are presented here from 12 participating sites. All participants used the same lot of samples, reagents, and columns to perform the assays. Elution time, peak area and peak area percent values were determined for all peaks ≥0.1% peak area, and statistical analysis was performed following ISO 5725-2 guideline principles. The results demonstrated adequate reproducibility, within any given site as well across all sites, indicating that standard UHPLC-based N-glycan analysis platforms are appropriate for general use.


Subject(s)
Chromatography, High Pressure Liquid/methods , Fluorescent Dyes/chemistry , Polysaccharides/analysis , Benzamides/chemistry , Binding Sites , Electrophoresis, Capillary/methods , Glycosylation , Humans , Limit of Detection , Reproducibility of Results , Spectrometry, Fluorescence/methods
2.
MAbs ; 8(1): 56-64, 2016.
Article in English | MEDLINE | ID: mdl-26466659

ABSTRACT

An international team that included 20 independent laboratories from biopharmaceutical companies, universities, analytical contract laboratories and national authorities in the United States, Europe and Asia was formed to evaluate the reproducibility of sample preparation and analysis of N-glycans using capillary electrophoresis of 8-aminopyrene-1,3,6-trisulfonic acid (APTS)-labeled glycans with laser induced fluorescence (CE-LIF) detection (16 sites) and ultra high-performance liquid chromatography (UHPLC, 12 sites; results to be reported in a subsequent publication). All participants used the same lot of chemicals, samples, reagents, and columns/capillaries to run their assays. Migration time, peak area and peak area percent values were determined for all peaks with >0.1% peak area. Our results demonstrated low variability and high reproducibility, both, within any given site as well across all sites, which indicates that a standard N-glycan analysis platform appropriate for general use (clone selection, process development, lot release, etc.) within the industry can be established.


Subject(s)
Fluorescence , Lasers , Polysaccharides/chemistry , Chromatography, High Pressure Liquid/methods , Electrophoresis, Capillary , Humans , Polysaccharides/analysis
3.
J Sep Sci ; 38(18): 3262-3270, 2015 Sep.
Article in English | MEDLINE | ID: mdl-26147246

ABSTRACT

A collaborative study on the robustness and portability of a capillary electrophoresis-mass spectrometry method for peptide mapping was performed by an international team, consisting of 13 independent laboratories from academia and industry. All participants used the same batch of samples, reagents and coated capillaries to run their assays, whereas they utilized the capillary electrophoresis-mass spectrometry equipment available in their laboratories. The equipment used varied in model, type and instrument manufacturer. Furthermore, different types of sheath-flow capillary electrophoresis-mass spectrometry interfaces were used. Migration time, peak height and peak area of ten representative target peptides of trypsin-digested bovine serum albumin were determined by every laboratory on two consecutive days. The data were critically evaluated to identify outliers and final values for means, repeatability (precision within a laboratory) and reproducibility (precision between laboratories) were established. For relative migration time the repeatability was between 0.05 and 0.18% RSD and the reproducibility between 0.14 and 1.3% RSD. For relative peak area repeatability and reproducibility values obtained were 3-12 and 9-29% RSD, respectively. These results demonstrate that capillary electrophoresis-mass spectrometry is robust enough to allow a method transfer across multiple laboratories and should promote a more widespread use of peptide mapping and other capillary electrophoresis-mass spectrometry applications in biopharmaceutical analysis and related fields.

4.
J Sep Sci ; 35(22): 3124-9, 2012 Nov.
Article in English | MEDLINE | ID: mdl-23065998

ABSTRACT

An international team including 12 laboratories from 11 independent biopharmaceutical companies in the United States and Switzerland was formed to evaluate the precision and robustness of imaged capillary isoelectric focusing for the charge heterogeneity analysis of monoclonal antibodies. The different laboratories determined the apparent pI and the relative distribution of the charged isoforms for a representative monoclonal antibody sample using the same capillary isoelectric focusing assay. Statistical evaluation of the data was performed to determine within and between laboratory consistencies and outlying information. The apparent pI data generated for each charged variant peak showed very good precision between laboratories with RSD values of less than 0.8%. Similarly, the RSD for the therapeutic monoclonal antibody charged variants percent peak area values are less than 11% across different laboratories using different analyst, different lots of ampholytes and multiple instruments. These results validate the appropriate use of imaged capillary isoelectric focusing in the biopharmaceutical industry in support of process development and regulatory submissions of therapeutic antibodies.


Subject(s)
Antibodies, Monoclonal/analysis , Electrophoresis, Capillary/methods , Isoelectric Focusing/methods , Laboratories/standards , Electrophoresis, Capillary/standards , Humans , Isoelectric Focusing/standards , Protein Isoforms/analysis , Switzerland