1.
J Chromatogr A ; 1709: 464382, 2023 Oct 25.
Article in English | MEDLINE | ID: mdl-37722175

ABSTRACT

A novel approach for multi-wavelength ultraviolet (UV) absorbance detection has been introduced employing a single board computer (SBC) with a field programmable gate array (FPGA), Red Pitaya SBC, to generate separated micro pulses for three deep-ultraviolet light-emitting diodes (DUV-LEDs), λmax = 235, 250, and 280 nm, along with data acquisition and processing via a custom-made program. The pulse set generation and data acquisition were synchronized using the SBC. The outputs of the three pulsing DUV-LEDs were combined and transmitted to the flow cell via a solarisation resistant trifurcated optical fiber (OF). An ultra-fast responding photodiode was connected to the optical-fiber-compatible flow cell to record the intensity of the DUV pulses. Upper limit of detector linearity (A95 %) was found to be 1917 mAU, 2189 mAU, and 1768 mAU at 235 nm, 250 nm, and 280 nm, respectively, with stray light ≤0.9 %. In addition, the effective path length (Leff) was estimated to be ≥98.0 % of the length of the used flow cell (50 mm). The new pulsed multi-LEDs absorbance detector (PMLAD) has been successfully coupled with a standard liquid chromatograph and utilized for the analysis of pharmaceuticals. Paracetamol, caffeine, and aspirin were simultaneously determined at 250, 280, and 235 nm, respectively, using the PMLAD. The absorbance ratios between the different wavelengths were applied to further confirm the identity of the studied compounds. Excellent linearity was achieved over a range of 0.1-3.2 µg/mL for paracetamol, 0.4-6.4 µg/mL for caffeine, and 0.8-12.8 µg/mL for aspirin with a regression correlation coefficient (r2) ≥ 0.99996. The quantitation limits (LOQs) were 0.10 µg/mL, 0.38 µg/mL, and 0.66 µg/mL for paracetamol, caffeine, and aspirin, respectively.


Subject(s)
Caffeine , Ultraviolet Rays , Acetaminophen , Chromatography, Liquid , Aspirin
2.
Talanta ; 218: 121144, 2020 Oct 01.
Article in English | MEDLINE | ID: mdl-32797901

ABSTRACT

We designed a simple, portable, low-cost and low-weight nondispersive infrared (NDIR) spectroscopy-based system for continuous remote sensing of atmospheric methane (CH4) with rapidly pulsed near-infrared light emitting diodes (NIR LED) at 1.65 µm. The use of a microcontroller with a field programmable gate array (µC-FPGA) enables on-the-fly and wireless streaming and processing of large data streams (~2 Gbit/s). The investigated NIR LED detection system offers favourable limits of detection (LOD) of 300 ppm (±5%) CH4,. All the generated raw data were processed automatically on-the-fly in the µC-FPGA and transferred wirelessly via a network connection. The sensing device was deployed for the portable sensing of atmospheric CH4 at a local landfill, resulting in quantified concentrations within the sampling area (ca 400 m2) in the range of 0.5%-3.35% CH4. This NIR LED-based sensor system offers a simple low-cost solution for continuous real-time, quantitative, and direct measurement of CH4 concentrations in indoor and outdoor environments, yet with the flexibility provided by the custom programmable software. It possesses future potential for remote monitoring of gases directly from mobile platforms such as smartphones and unmanned aerial vehicles (UAV).

SELECTION OF CITATIONS
SEARCH DETAIL
...