Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Rev Sci Instrum ; 89(10): 10D105, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30399672

ABSTRACT

The present work concerns the measurements obtained with the Tungsten (W) Environment in Steady-state Tokamak (WEST) visible spectroscopy system during the first experimental campaign. This system has been developed in the framework of the WEST project that equipped the existing Tore Supra device with a tungsten divertor in order to test actively cooled tungsten Plasma Facing Components (PFC) in view of preparing for ITER operation. The goal of this diagnostic is to measure the PFC sources and the deuterium recycling with spectral, spatial, and temporal resolution adapted to the predicted power deposition profiles on the objects observed. Three kinds of PFCs are monitored: the Ion Cyclotron Resonance Heating (ICRH) antenna and Low Hybrid Current Drive (LHCD) launcher W limiters; one of the 6 W inner bumpers; and the upper and lower W divertors. Large-aperture in-vessel actively cooled optical systems (f-number ∼ 3) were installed for each view and connected to optical fibres. A total of 240 optical fibers can be distributed on various detection systems including a fast response-time, multi-channel, filtered photodetector-based "Filterscope" system, developed by Oak Ridge National Laboratory (USA) as well as grating spectrometers optimized for multi-sightline analysis. The first WEST experimental campaign conducted in 2017 has been dedicated to plasma start-up development during which the visible spectroscopy system has provided crucial information related to the impurity content first and then impurity sources. The diagnostic setup for that first experimental campaign was limited to the inner bumper and outer limiters but was sufficient to demonstrate that the optical setup was in accordance with the specifications. The radiance calibration procedure allowed us to estimate fluxes from the main limiter of about 8 × 1018 atoms/(s m2) and to show a first W source radial profile along the outboard limiter.

2.
Rev Sci Instrum ; 87(11): 11E309, 2016 Nov.
Article in English | MEDLINE | ID: mdl-27910500

ABSTRACT

The present work concerns the development of a W sources assessment system in the framework of the tungsten-W environment in steady state tokamak project that aims at equipping the existing Tore Supra device with a tungsten divertor in order to test actively cooled tungsten Plasma Facing Components (PFCs) in view of preparing ITER operation. The goal is to assess W sources and D recycling with spectral, spatial, and temporal resolution adapted to the PFCs observed. The originality of the system is that all optical elements are installed in the vacuum vessel and compatible with steady state operation. Our system is optimized to measure radiance as low as 1016 Ph/(m2 s sr). A total of 240 optical fibers will be deployed to the detection systems such as the "Filterscope," developed by Oak Ridge National Laboratory (USA) and consisting of photomultiplier tubes and filters, or imaging spectrometers dedicated to Multiview analysis.

3.
Rev Sci Instrum ; 84(7): 073501, 2013 Jul.
Article in English | MEDLINE | ID: mdl-23902057

ABSTRACT

This paper describes the design and operation of a new tungsten (W) injection system for impurity transport experiments in the Tore Supra tokamak. The system is mounted on a reciprocating manipulator and injects a controlled amount of gaseous tungsten hexacarbonyl, W(CO)6 at arbitrary depth in the scrape-off layer, using an inertially activated valve. Injected W(CO)6 is dissociated in the plasma, forming a radially localized plume of W atoms. The injector does not require an external gas feed and can perform a large number of injections from an on-board reservoir of W(CO)6. Some examples of W injections in Tore Supra are included, demonstrating successful operation and discussing some technical issues of the injector prototype.

4.
Rev Sci Instrum ; 84(1): 016107, 2013 Jan.
Article in English | MEDLINE | ID: mdl-23387713

ABSTRACT

The Note reports on experimental studies of ripple born fast electrons within the TORE-SUPRA facility, which were performed by means of a modified measuring head equipped with diamond detectors designed especially for recording the electron-induced Cherenkov radiation. There are presented signals produced by fast electrons in the TORE-SUPRA machine, which were recorded during two experimental campaigns performed in 2010. Shapes of these electron-induced signals are considerably different from those observed during the first measurements carried out by the prototype Cherenkov probe in 2008. An explanation of the observed differences is given.

5.
Rev Sci Instrum ; 82(12): 123505, 2011 Dec.
Article in English | MEDLINE | ID: mdl-22225216

ABSTRACT

A new in situ reciprocating probe system has been developed to provide scrape-off layer measurements in the Tore Supra tokamak. The probe motion is provided by the rotation of an energized coil in the tokamak magnetic field. Simple analytic approximations to the exact numerical model were used to identify the important parameters that govern the dynamics of the system, and optimize the coil geometry, the electrical circuit, and the stiffness of the retaining spring. The linear speed of the probe is directly proportional to the current induced by the coil's rotation; its integral gives the coil position, providing a means to implement real-time feedback control of the probe motion. Two probes were recently mounted on a movable outboard antenna protection limiter in Tore Supra and provided automatic measurements during the 2011 experimental campaign.

6.
Rev Sci Instrum ; 81(1): 013504, 2010 Jan.
Article in English | MEDLINE | ID: mdl-20113097

ABSTRACT

The paper presents a schematic design and tests of a system applicable for measurements of fast electron pulses emitted from high-temperature plasma generated inside magnetic confinement fusion machines, and particularly in the TORE-SUPRA facility. The diagnostic system based on the registration of the Cherenkov radiation induced by fast electrons within selected solid radiators is considered, and electron low-energy thresholds for different radiators are given. There are some estimates of high thermal loads, which might be deposited by intense electron beams upon parts of the diagnostic equipment within the TORE-SUPRA device. There are some proposed measures to overcome this difficulty by the selection of appropriate absorption filters and Cherenkov radiators, and particularly by the application of a fast-moving reciprocating probe. The paper describes the measuring system, its tests, as well as some results of the preliminary measurements of fast electrons within TORE-SUPRA facility.

7.
Rev Sci Instrum ; 79(7): 073502, 2008 Jul.
Article in English | MEDLINE | ID: mdl-18681699

ABSTRACT

The retarding field analyzer (RFA) is one of the only widely accepted diagnostics for measurements of ion temperature Ti in the tokamak scrape-off layer. In this paper we analyze some instrumental effects of the RFA and their influence on Ti measurements. It is shown that selective ion transmission through the RFA slit is responsible for an overestimation of Ti by less than 14%, even for a relatively thick slit plate. Therefore, thicker slit plates are preferable, since they reduce, e.g., the risk of melting during off-normal events, and the effect of positive space charge inside the cavity. The influence of the electron repelling grid, as well as misalignment of the slit with respect to the magnetic field on Ti measurements are negligible.

SELECTION OF CITATIONS
SEARCH DETAIL
...