Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 35
Filter
1.
J Clin Med ; 13(4)2024 Feb 06.
Article in English | MEDLINE | ID: mdl-38398253

ABSTRACT

Left atrial appendage occlusion (LAAO) is an increasingly used alternative to oral anticoagulation in patients with atrial fibrillation, especially in patients with absolute/relative contraindications to these therapies. This review will cover three main aspects of the procedure. In the fist part of the manuscript, we focus on patient selection. We describe three main categories of patients with primary indication to LAAO, namely patients with previous or at a high risk of intracerebral bleeding, patients with a history of major gastrointestinal bleeding and patients with end-stage renal disease and absolute contraindication to novel oral anticoagulants. Some other potential indications are also described. In the second part of the manuscript, we review available devices, trying to highlight different aspects and potential specific advantages. The last section overviews different ways for pre-, intra- and postprocedural imaging, in order to improve procedural safety and efficacy and ameliorate patient outcome. The characteristics of available contemporary devices and the role of imaging in procedural planning, intraprocedural guidance and follow-up are described.

2.
J Clin Med ; 12(20)2023 Oct 20.
Article in English | MEDLINE | ID: mdl-37892796

ABSTRACT

This study aimed to compare the peri-procedural success and complication rate within a large registry of intra-cardiac echocardiography (ICE)- vs. transesophageal echocardiography (TEE)-guided left atrial appendage occlusion (LAAO) procedures with a Watchmann FLX device. Data from 772 LAAO procedures, performed at 26 Italian centers, were reviewed. Technical success was considered as the final implant of a Watchmann FLX device in LAA; the absence of pericardial tamponade, peri-procedural stroke and/or systemic embolism, major bleeding and device embolization during the procedure was defined as a procedural success. One-year stroke and major bleeding rates were evaluated as outcome. ICE-guided LAA occlusion was performed in 149 patients, while TEE was used in 623 patients. Baseline characteristics were similar between the ICE and TEE groups. The technical success was 100% in both groups. Procedural success was also extremely high (98.5%), and was comparable between ICE (98.7%) and TEE (98.5%). ICE was associated with a slightly longer procedural time (73 ± 31 vs. 61.9 ± 36 min, p = 0.042) and shorter hospital stay (5.3 ± 4 vs. 5.8 ± 6 days, p = 0.028) compared to the TEE group. At one year, stroke and major bleeding rates did not differ between the ICE and TEE groups. A Watchmann FLX device showed high technical and procedural success rate, and ICE guidance does not appear inferior to TEE.

4.
J Intern Med ; 291(2): 197-206, 2022 02.
Article in English | MEDLINE | ID: mdl-34487597

ABSTRACT

BACKGROUND AND OBJECTIVES: The absence of obstructive coronary artery disease (CAD) in patients with angina is common, but its prognosis is debated. We investigated outcomes of such patients to identify predictors of cardiovascular events. METHODS: We selected 1014 patients with angina, evidence of myocardial ischemia at the electrocardiogram (ECG) exercise test or imaging stress tests, and nonobstructive CAD (absence of lumen diameter reduction ≥50%) at coronary angiography between 1999 and 2015. Note that, 1905 age- and risk factors-matched asymptomatic subjects served as "real-world" comparators. The primary endpoint was the occurrence of all-cause death or myocardial infarction. RESULTS: At 6-years median follow-up (interquartile range, 3-9 years), the primary endpoint occurred in 53 patients (5.5%, 0.92/100 person-years). Besides similar event rates compared with asymptomatic subjects (hazard ratio [HR] 0.85, 95% confidence interval [CI] 0.62-1.15, p = 0.28), the index population showed a very heterogeneous prognosis. Patients with nonobstructive CAD (HR 1.85, 95% CI 1.02-3.37, p = 0.04, compared with "normal" coronary arteries) and ischemia at imaging tests (HR 2.11, 95% CI 1.07-4.14, p = 0.03, compared with ischemia detected only at the ECG exercise test) were at higher risk and those with both these components showing even >10-fold event rates as compared with the absence of both. Three-hundred and twenty-five patients (34%) continued to experience angina, 69 (7.2%) underwent repeat coronary angiography, and 14 (1.5%) had consequent coronary revascularization for atherosclerosis progression. CONCLUSION: Apart from the impaired quality of life, angina without obstructive CAD has an overall benign but very heterogeneous prognosis. Nonobstructive CAD and myocardial ischemia at imaging tests both confer a higher risk.


Subject(s)
Angina Pectoris , Coronary Artery Disease , Myocardial Ischemia , Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Humans , Prognosis , Quality of Life , Risk Factors , Severity of Illness Index
5.
J Am Heart Assoc ; 10(20): e020358, 2021 10 19.
Article in English | MEDLINE | ID: mdl-34622675

ABSTRACT

Background The relative contribution of amyloid and fibrosis to extracellular volume expansion in cardiac amyloidosis (CA) has never been defined. Methods and Results We included all patients diagnosed with amyloid light-chain (AL) or transthyretin cardiac amyloidosis at a tertiary referral center between 2014 to 2020 and undergoing a left ventricular endomyocardial biopsy. Patients (n=37) were more often men (92%), with a median age of 72 years (interquartile range, 68-81). Lambda-positive AL was found in 14 of 19 AL cases (38%) and kappa-positive AL in 5 of 19 (14%), while transthyretin was detected in the other 18 cases (48%). Amyloid deposits accounted for 15% of tissue sample area (10%-30%), without significant differences between AL and transthyretin amyloidosis. All patients displayed myocardial fibrosis, with a median extent of 15% of tissue samples (10%-23%; range, 5%-60%), in the absence of spatial overlap with amyloid deposits. Interstitial fibrosis was often associated with mild and focal subendocardial fibrosis. The extent of fibrosis or the combination of amyloidosis and fibrosis did not differ significantly between transthyretin amyloidosis and AL subgroups. In 20 patients with myocardial T1 mapping at cardiac magnetic resonance, the combined amyloid and fibrosis extent displayed a modest correlation with extracellular volume (r=0.661, P=0.001). The combined amyloid and fibrosis extent correlated with high-sensitivity troponin T (P=0.035) and N-terminal pro-B-type natriuretic peptide (P=0.002) serum levels. Conclusions Extracellular spaces in cardiac amyloidosis are enlarged to a similar extent by amyloid deposits and fibrotic tissue. Their combination can better explain the increased extracellular volume at cardiac magnetic resonance and circulating biomarkers than amyloid extent alone.


Subject(s)
Amyloid Neuropathies, Familial , Plaque, Amyloid , Prealbumin , Aged , Amyloid , Amyloid Neuropathies, Familial/diagnosis , Amyloid Neuropathies, Familial/diagnostic imaging , Biopsy , Fibrosis , Humans , Male
6.
ESC Heart Fail ; 8(2): 1216-1229, 2021 04.
Article in English | MEDLINE | ID: mdl-33566429

ABSTRACT

AIMS: This study aimed to evaluate a novel echocardiographic algorithm for quantitative estimation of pulmonary artery wedge pressure (PAWP) and pulmonary vascular resistance (PVR) in patients with heart failure and pulmonary hypertension (PH) scheduled to right heart catheterization (RHC). METHODS AND RESULTS: In this monocentric study, 795 consecutive patients (427 men; age 68.4 ± 12.1 years) undergoing echocardiography and RHC were evaluated. Multiple regression analysis was performed to identify echocardiographic predictors of PAWP and PVR measured by RHC in the derivation group (the first 200 patients). The diagnostic accuracy of the model was then tested in the validation group (the remaining 595 patients). PH was confirmed by RHC in 507 (63.8%) patients, with 192 (24.2%) cases of precapillary PH, 248 (31.2%) of postcapillary PH, and 67 (8.4%) of combined PH. At regression analysis, tricuspid regurgitation maximal velocity, mitral E/e' ratio, left ventricular ejection fraction, right ventricular fractional area change, inferior vena cava diameter, and left atrial volume index were included in the model (R = 0.8, P < 0.001). The model showed a high diagnostic accuracy in estimating elevated PAWP (area under the receiver operating characteristic curve = 0.97, 92% sensitivity, and 93% specificity, P < 0.001) and PVR (area under the receiver operating characteristic curve = 0.96, 89% sensitivity, and 92% specificity, P < 0.001), outperforming 2016 American Society of Echocardiography/European Association of Cardiovascular Imaging recommendations (P < 0.001) and Abbas' equation (P < 0.001). Bland-Altman analysis showed satisfactory limits of agreement between echocardiography and RHC for PAWP (bias 0.7, 95% confidence interval -7.3 to 8.7) and PVR (bias -0.1, 95% confidence interval -2.2 to 1.9 Wood units), without indeterminate cases. CONCLUSIONS: A novel quantitative echocardiographic approach for the estimation of PAWP and PVR has high diagnostic accuracy in patients with heart failure and PH.


Subject(s)
Echocardiography , Ventricular Function, Left , Aged , Aged, 80 and over , Humans , Male , Middle Aged , Pulmonary Wedge Pressure , Stroke Volume , Vascular Resistance
7.
Clin Res Cardiol ; 110(5): 711-724, 2021 May.
Article in English | MEDLINE | ID: mdl-32514602

ABSTRACT

RATIONALE: Despite advances in treatment of acute myocardial infarction (AMI), many patients suffer significant myocardial damage with cardiac dysfunction. Sympathetic renal denervation (RD) may reduce adrenergic activation following AMI. OBJECTIVE: To investigate the potential role of RD limiting myocardial damage and remodeling when performed immediately after AMI. METHODS AND RESULTS: Sixteen farm pigs underwent 90 min left anterior descending artery balloon occlusion. Eight pigs underwent RD immediately after reperfusion. LV function, extent of myocardium at risk, and myocardial necrosis were quantified by cardiac magnetic resonance 5 and 30 days after AMI. 123I-MIBG scintigraphy was performed 31 days after AMI to image myocardial sympathetic innervation. Heart norepinephrine was quantified (from necrotic, border and remote zone). RD and control did not differ in myocardium at risk extent (59 ± 9 vs 55 ± 11% of LV mass) at 5 days. At 30 days CMR, RD pigs had smaller necrotic areas than control as assessed by gadolinium delay enhancement (18 ± 7 vs 30 ± 12% of LV mass, p = 0.021) resulting in improved myocardial salvage index (60 ± 11 vs 44 ± 27%, p < 0.001). RD pigs had higher cardiac output (3.7 ± 0.8 vs 2.66 ± 0.7 L/min, p < 0.001) and lower LV end diastolic volume (98 ± 16 vs 113 ± 31 ml, p = 0.041). 123I-MIBG defect extension was smaller in RD than control (60 ± 28 vs 78 ± 17%, p < 0.05) with significant reduction in the difference between innervation and perfusion defects (25 ± 12 vs 36 ± 30%, p = 0.013). NE content from necrotic area (238; IQR 464 vs 2546; IQR 1727 ng/g in RD and control, respectively, p < 0.001) and from border zone (295; IQR 264 vs 837; IQR 207 in RD and control, respectively, p = 0.031) was significantly lower in RD than control. CONCLUSIONS: RD results in increased myocardial salvage and better cardiac function, when performed immediately after AMI. Reduction of sympathetic activation with preservation of cardiac sympathetic functionality warranted by RD may sustain these effects.


Subject(s)
Myocardial Infarction/surgery , Myocardium/pathology , Renal Artery/surgery , Sympathectomy/methods , 3-Iodobenzylguanidine/administration & dosage , Animals , Disease Models, Animal , Humans , Male , Myocardial Infarction/physiopathology , Myocardial Reperfusion , Norepinephrine/metabolism , Renal Artery/innervation , Swine , Ventricular Remodeling
8.
G Ital Cardiol (Rome) ; 21(4 Suppl 2): 29S-33S, 2020 04.
Article in Italian | MEDLINE | ID: mdl-32250367

ABSTRACT

The impressive advances in structural heart disease interventions in the last decade led to renewed interest in intracardiac echocardiography (ICE). The potential of ICE to avoid transesophageal echocardiography with its known limits, has supported ICE technology progress and wider clinical use. This review summarizes relevant evidence about ICE and provides the structural interventionalist with an illustrative guide on the use of ICE to guide various structural heart interventions.


Subject(s)
Echocardiography/methods , Heart Diseases/diagnostic imaging , Echocardiography, Transesophageal/methods , Heart Diseases/therapy , Humans
9.
Coron Artery Dis ; 31(1): 27-34, 2020 01.
Article in English | MEDLINE | ID: mdl-31658146

ABSTRACT

AIMS: To assess the long-term outcomes of patients treated with sirolimus-eluting Stentys stent in a real-life setting. BACKGROUND: Few data regarding the safety and effectiveness of self-apposing sirolimus-eluting Stentys stent are available. METHODS: 278 patients (30% stable coronary artery disease, 70% acute coronary syndromes, and 54% on unprotected left main) treated with sirolimus eluting Stentys stent were retrospectively included in the self-aPposing, bAlloon-delivered, siRolimus-eluting stent for the Treatment of the coronary Artery disease multicenter registry. Major adverse cardiovascular events (MACE, a composite of cardiac death, myocardial infarction, target lesion revascularization, stent thrombosis) were the primary end-point, single components of MACE were the secondary ones. RESULTS: After 13 months (interquartile range 5-32), MACE was 14%. Stent thrombosis occurred in 3.9% of the patients (2.5% definite stent thrombosis and 1.4% probable stent thrombosis), 66% of them presenting with ST-segment elevation myocardial infarction (STEMI) at admission. Cardiovascular death, target lesion revascularization and myocardial infarction was 4.7%, 8.3%, and 7.2%, respectively. At multivariate analysis, risk of MACE was increased by diabetes (hazard ratios 4.76; P = 0.002) but was not affected by the indication leading to sirolimus-eluting Stentys stent implantation (marked vessel tapering vs. coronary ecstasies, hazard ratios 0.74, P = 0.71). CONCLUSION: Sirolimus-eluting Stentys stent may represent a potential solution for specific coronary anatomies such as bifurcation, ectasic, or tapered vessels. Risk of stent thrombosis appears related to clinical presentation with STEMI and to anatomic features, stressing the importance of the use of intracoronary imaging for self-expandable stents implantation.


Subject(s)
Acute Coronary Syndrome/surgery , Coronary Artery Disease/surgery , Drug-Eluting Stents , Percutaneous Coronary Intervention/methods , ST Elevation Myocardial Infarction/surgery , Aged , Antibiotics, Antineoplastic/administration & dosage , Cardiovascular Diseases/mortality , Female , Humans , Male , Middle Aged , Myocardial Infarction/epidemiology , Myocardial Revascularization/statistics & numerical data , Postoperative Complications/epidemiology , Registries , Retrospective Studies , Sirolimus/administration & dosage , Thrombosis/epidemiology , Treatment Outcome
11.
Catheter Cardiovasc Interv ; 93(2): 208-215, 2019 02 01.
Article in English | MEDLINE | ID: mdl-30298593

ABSTRACT

OBJECTIVES: To compare the effectiveness and safety of self-expandable, sirolimus-eluting Stentys stents (SES) and second-generation drug-eluting stents (DES-II) for the treatment of the unprotected left main (ULM). BACKGROUND: SES may provide a valuable option to treat distal ULM, particularly when significant caliber gaps with side branches are observed. METHODS: Patients from the multicenter SPARTA (clinicaltrials.gov: NCT02784405) and FAILS2 registries were included. Propensity-score with matching was performed to account for the lack of randomization. Primary end-point was the rate of major adverse cardiovascular events (MACE, a composite of all cause death, myocardial infarction, target lesion revascularization [TLR], unstable angina and definite stent thrombosis [ST]). Single components of MACE were the secondary end-points. RESULTS: Overall, 151 patients treated with SES and 1270 with DES-II were included; no differences in MACE rate at 250 days were observed (9.8% vs. 11.5%, P = 0.54). After propensity score with matching, 129 patients treated with SES and 258 with DES-II, of which about a third of female gender, were compared. After a follow-up of 250 days, MACE rate did not differ between the two groups (9.9% vs. 8.5%, P = 0.66), as well as the rate of ULM TLR (1.6% vs. 3.1%, P = 0.36) and definite ST (0.8% vs. 1.2%, P = 0.78). These results were consistent also when controlling for the treatment with provisional vs. 2-stents strategies for the ULM bifurcation. CONCLUSION: SES use for ULM treatment was associated with a similar MACE rate compared to DES-II at an intermediate-term follow-up. SES might represent a potential option in this setting.


Subject(s)
Cardiovascular Agents/administration & dosage , Coronary Artery Disease/therapy , Drug-Eluting Stents , Percutaneous Coronary Intervention/instrumentation , Self Expandable Metallic Stents , Sirolimus/administration & dosage , Aged , Aged, 80 and over , Alloys , Cardiovascular Agents/adverse effects , Comparative Effectiveness Research , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/mortality , Female , Humans , Male , Middle Aged , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/mortality , Prosthesis Design , Registries , Retrospective Studies , Risk Assessment , Risk Factors , Sirolimus/adverse effects , Time Factors , Treatment Outcome
15.
JACC Cardiovasc Interv ; 11(11): 1086-1092, 2018 06 11.
Article in English | MEDLINE | ID: mdl-29880104

ABSTRACT

OBJECTIVES: This study sought to evaluate the feasibility, safety, and efficacy of intracardiac echocardiography (ICE)-guided versus transesophageal echocardiography (TEE)-guided left atrial appendage occlusion (LAAO) by the use of Amplatzer Cardiac Plug or Amulet devices included in a large Italian registry. BACKGROUND: TEE is widely used for LAAO procedure guidance. ICE may be a potential alternative imaging modality in LAAO. METHODS: Data from 604 LAAO procedures performed in 16 Italian centers were reviewed. ICE-guided LAAO was performed in 187 patients, whereas TEE was used in 417 patients. Procedural success was defined as LAAO without occurrence of pericardial tamponade, stroke, systemic embolism with end organ damage, major bleeding, and device embolization. Stroke, transient ischemic attack, major bleeding, overall and cardiovascular death were analyzed. RESULTS: CHA2DS2-VASc (congestive heart failure, hypertension, age ≥75 years, diabetes mellitus, prior stroke or transient ischemic attack or thromboembolism, vascular disease, age 65 to 74 years, sex category) and HAS-BLED (hypertension, abnormal renal and liver function, stroke, bleeding, labile international normalized ratio, elderly, drugs or alcohol) scores were similar between the ICE and TEE groups. TEE implied lower procedural (delta 12 min) and fluoroscopy time (delta 5 min) when compared with ICE. Procedural success was similarly high (≥94%) between the TEE and ICE groups with a complication rate of 6.5% for TEE versus 4.2% for ICE (odds ratio: 1.468; 95% confidence interval: 0.681 to 3.166; p = 0.327). At median follow-up of 451 days (interquartile range: 162 to 899 days), the rate of cerebral ischemic events was similar between TEE-guided and ICE-guided procedures. CONCLUSIONS: ICE-guided LAAO by means of Amplatzer devices may represent a second alternative imaging modality after an appropriate learning curve and bearing in mind that pre-procedural computed tomography imaging is mandatory. When comparing ICE with TEE, TEE remains the gold standard.


Subject(s)
Atrial Appendage/diagnostic imaging , Atrial Fibrillation/therapy , Cardiac Catheterization/methods , Echocardiography, Transesophageal , Ultrasonography, Interventional/methods , Aged , Aged, 80 and over , Atrial Fibrillation/diagnostic imaging , Cardiac Catheterization/adverse effects , Cardiac Catheterization/instrumentation , Echocardiography, Transesophageal/adverse effects , Feasibility Studies , Female , Humans , Italy , Male , Predictive Value of Tests , Registries , Retrospective Studies , Time Factors , Treatment Outcome , Ultrasonography, Interventional/adverse effects
17.
Curr Pharm Des ; 23(22): 3285-3300, 2017.
Article in English | MEDLINE | ID: mdl-28677508

ABSTRACT

BACKGROUND: In the last decades, interventional cardiology has received fast and wide implementation as an effective alternative treatment to surgery for several congenital and acquired diseases. In this scenario, imaging provides solutions for most clinical needs, from diagnosis to prognosis and risk stratification, as well as anatomical and functional assessment. METHODS: In this review article, we present recent innovations in medical imaging for structural heart disease and coronary artery disease, emphasizing the progress achieved in the field of multimodality imaging and the solutions proposed to some as-yet unresolved technical problems for safe and effective procedural performance. RESULTS: Intra-procedural guidance can be facilitated by established multimodality cardiac imaging such as transesophageal 2D and 3D echocardiography and by novel techniques as echo-fluoroscopy overlay and 3D modeling/printing. Computed tomography and magnetic resonance imaging are particularly helpful for preprocedural morphology assessment and device sizing. CONCLUSION: Successful planning, performance, and aftercare of interventions depend heavily on accurate imaging for both structural heart disease and coronary artery disease.


Subject(s)
Cardiovascular Diseases/diagnostic imaging , Coronary Angiography/trends , Echocardiography, Three-Dimensional/trends , Magnetic Resonance Imaging, Cine/trends , Tomography, X-Ray Computed/trends , Cardiovascular Diseases/surgery , Coronary Angiography/methods , Echocardiography, Three-Dimensional/methods , Humans , Magnetic Resonance Imaging, Cine/methods , Multimodal Imaging/methods , Multimodal Imaging/trends , Tomography, X-Ray Computed/methods
18.
EuroIntervention ; 13(Z): Z37-Z41, 2017 May 15.
Article in English | MEDLINE | ID: mdl-28504228

ABSTRACT

The aim of this report is to analyse trends in Italian cathlab activity between 2010 and 2015. Data were obtained from the national database of the Italian Society of Interventional Cardiology (GISE), which includes 97% of Italian cardiac catheterisation laboratories. The number of percutaneous coronary interventions (PCI) has remained relatively stable in the past five years. We have observed a significant increase in the number of primary PCI (pPCI) from 471.5 to 557.5 per million inhabitants with a consequent reduction of rescue primary PCI/fibrinolysis. One of the possible explanations for this might be the extensive networking for primary PCI and the adoption of Stent for Life initiatives in five regions. There has been a notably increased use of drug-eluting stents and, despite the fact that the introduction of bioabsorbable vascular scaffolds is recent, there is a slight, progressively positive trend. Invasive physiologic evaluation of coronary stenosis has markedly increased. Radial artery access has become the default option for PCI and for pPCI. In the last five years, TAVI procedures have doubled in number, while MitraClip and mitral repair procedures have shown a fivefold increase. Left atrial appendage (LAA) occlusion procedures have more than doubled in four years.


Subject(s)
Cardiac Catheterization , Cardiac Surgical Procedures , Heart , Cardiac Catheterization/methods , Coronary Angiography/methods , Coronary Stenosis/surgery , Drug-Eluting Stents , Humans , Italy
19.
Heart ; 102(24): 1969-1973, 2016 12 15.
Article in English | MEDLINE | ID: mdl-27492943

ABSTRACT

OBJECTIVE: Percutaneous left atrial appendage (LAA) occlusion has been developed as a viable option for stroke and thromboembolism prevention in patients with non-valvular atrial fibrillation (NVAF) and at high risk for cerebral cardioembolic events. Data on device implantation and long-term follow-up from large cohorts are limited. METHODS: 110 consecutive patients with NVAF and contraindications to oral anticoagulants (OACs) underwent LAA occlusion procedures and achieved a longer than 1 year follow-up. All patients were enrolled in a prospective registry. Procedures were performed using the Amplatzer Cardiac Plug or Amulet guided by fluoroscopy and intracardiac echocardiography. RESULTS: Mean age of the population was 77±6 years old; 68 were men. Atrial fibrillation was paroxysmal in 20%, persistent in 15.5% and permanent in 64.5% of cases, respectively. Mean CHA2DS2-VASc and HAS-BLED scores were 4.3±1.3 and 3.4±1, respectively. Technical success (successful deployment and implantation of device) was achieved in 100% of procedures. Procedural success (technical success without major procedure-related complications) was achieved in 96.4%, with a 3.6% rate of major procedural complications (three cases of pericardial tamponade requiring drainage and one case of major bleeding). Mean follow-up was 30±12 months (264 patient-years). Annual rates for ischaemic stroke and for other thromboembolic events were respectively 2.2% and 0%, and annual rate for major bleeding was 1.1%. CONCLUSIONS: Our data suggest LAA occlusion in high-risk patients with NVAF not suitable for OACs is feasible and associated with low complication rates as well as low rates of stroke and major bleeding at long-term follow-up.


Subject(s)
Atrial Fibrillation/therapy , Cardiac Catheterization , Stroke/prevention & control , Administration, Oral , Aged , Aged, 80 and over , Anticoagulants/administration & dosage , Atrial Appendage/diagnostic imaging , Atrial Appendage/physiopathology , Atrial Fibrillation/complications , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/physiopathology , Cardiac Catheterization/adverse effects , Cardiac Catheterization/instrumentation , Contraindications , Echocardiography , Female , Fluoroscopy , Follow-Up Studies , Hemorrhage/etiology , Humans , Kaplan-Meier Estimate , Male , Patient Selection , Prospective Studies , Radiography, Interventional/methods , Registries , Risk Assessment , Risk Factors , Stroke/etiology , Stroke/mortality , Time Factors , Treatment Outcome , Ultrasonography, Interventional/methods
20.
Cardiovasc Revasc Med ; 17(3): 186-9, 2016.
Article in English | MEDLINE | ID: mdl-26944852

ABSTRACT

AIM: Self-expanding stents represent a re-emerging option for percutaneous coronary interventions. Their application covers a wide spectrum of angiographic situations, i.e., coronary bifurcations, acute coronary syndromes with large thrombotic burden and stenosis of ectatic coronaries. We review our experience with self-expanding stents for different clinical and angiographic indications, with long clinical follow-up. METHODS: From 2011 to 2013 we used self-expanding STENTYS® stents in 40 consecutive patients followed-up for death from any cause and from cardiovascular cause, myocardial infarction, target lesion revascularization (TLR), stent thrombosis (mean 21±13months). We also revised rate of procedural outcomes, acute stent thrombosis and TLR in patients treated with conventional stents for similar clinical/angiographic situations, in the same period at our institution. RESULTS: We identified three anatomical settings of STENTYS® use: coronary bifurcations with proximal/distal main branch diameter discrepancy (55% of cases), massive thrombotic burden in the setting of acute coronary syndrome (35% of cases) and stenosis of ectatic coronaries (15%). We observed one death related to acute heart failure and 1 case (2.5%) of acute stent thrombosis (2.5% in the control group). During follow-up 2 cases of stent restenosis leading to TLR (5%) occurred (6.25% in the control group). CONCLUSIONS: According to our real life experience, self-expanding STENTYS® stents appear to be an effective tool for different angiographic situations in which they may be preferable to balloon-expandable stents, showing a low rate of complications and good results at long term follow-up.


Subject(s)
Acute Coronary Syndrome/therapy , Coronary Artery Disease/therapy , Coronary Thrombosis/therapy , Coronary Vessels , Percutaneous Coronary Intervention/instrumentation , Stents , Acute Coronary Syndrome/diagnostic imaging , Acute Coronary Syndrome/mortality , Aged , Aged, 80 and over , Cause of Death , Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/mortality , Coronary Thrombosis/diagnostic imaging , Coronary Thrombosis/mortality , Coronary Vessels/diagnostic imaging , Coronary Vessels/pathology , Dilatation, Pathologic , Female , Humans , Italy , Male , Middle Aged , Myocardial Infarction/etiology , Myocardial Infarction/mortality , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/mortality , Prosthesis Design , Risk Factors , Time Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...