Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 51
Filter
Add more filters










Publication year range
1.
Sci Rep ; 14(1): 10479, 2024 05 07.
Article in English | MEDLINE | ID: mdl-38714793

ABSTRACT

Enterochromaffin (EC) cells located within the intestinal mucosal epithelium release serotonin (5-HT) to regulate motility tones, barrier function and the immune system. Electroanalytical methodologies have been able to monitor steady state basal extracellular 5-HT levels but are unable to provide insight into how these levels are influenced by key regulatory processes such as release and uptake. We established a new measurement approach, amperometry approach curve profiling, which monitors the extracellular 5-HT level at different electrode-tissue (E-T) distances. Analysis of the current profile can provide information on contributions of regulatory components on the observed extracellular 5-HT level. Measurements were conducted from ex vivo murine ileum and colon using a boron-doped diamond (BDD) microelectrode. Amperometry approach curve profiling coupled with classical pharmacology demonstrated that extracellular 5-HT levels were significantly lower in the colon when compared to the ileum. This difference was due to a greater degree of activity of the 5-HT transporter (SERT) and a reduced amount of 5-HT released from colonic EC cells. The presence of an inhibitory 5-HT4 autoreceptor was observed in the colon, where a 40% increase in extracellular 5-HT was the half maximal inhibitory concentration for activation of the autoreceptor. This novel electroanalytical approach allows estimates of release and re-uptake and their contribution to 5-HT extracellular concentration from intestinal tissue be obtained from a single series of measurements.


Subject(s)
Colon , Ileum , Intestinal Mucosa , Serotonin , Serotonin/metabolism , Animals , Mice , Ileum/metabolism , Intestinal Mucosa/metabolism , Colon/metabolism , Enterochromaffin Cells/metabolism , Microelectrodes , Serotonin Plasma Membrane Transport Proteins/metabolism , Male , Electrochemical Techniques/methods , Mice, Inbred C57BL
2.
Biosens Bioelectron ; 254: 116224, 2024 Jun 15.
Article in English | MEDLINE | ID: mdl-38513539

ABSTRACT

Extracellular vesicles (EVs) are pivotal in cell-to-cell communication due to the array of cargo contained within these vesicles. EVs are considered important biomarkers for identification of disease, however most measurement approaches have focused on monitoring specific surface macromolecular targets. Our study focuses on exploring the electroactive component present within cargo from EVs obtained from various cancer and non-cancer cell lines using a disk carbon fiber microelectrode. Variations in the presence of oxidizable components were observed when the total cargo from EVs were measured, with the highest current detected in EVs from MCF7 cells. There were differences observed in the types of oxidizable species present within EVs from MCF7 and A549 cells. Single entity measurements showed clear spikes due to the detection of oxidizable cargo within EVs from MCF7 and A549 cells. These studies highlight the promise of monitoring EVs through the presence of varying electroactive components within the cargo and can drive a wave of new strategies towards specific detection of EVs for diagnosis and prognosis of various diseases.


Subject(s)
Biosensing Techniques , Extracellular Vesicles , Neoplasms , Humans , Cell Line, Tumor , MCF-7 Cells , Cell Communication , Neoplasms/diagnosis , Neoplasms/metabolism
3.
Analyst ; 149(5): 1502-1508, 2024 Feb 26.
Article in English | MEDLINE | ID: mdl-38264850

ABSTRACT

Electrochemical sensing techniques rely on redox reactions taking place at the electrode surface. The configuration of this surface is of the utmost importance in the advancement of electrochemical sensors. The majority of previous electrode manufacturing methods, including 3D printing have produced electrodes with flat surfaces. There is a distinct potential for 3D printing to create intricate and distinctive electrode surface shapes. In the proposed work, 3D printed carbon black polylactic acid electrodes with nine different surface morphologies were made. These were compared to a flat surface electrode. To evaluate the performance of the electrodes, measurements were conducted in three different redox probes (ferrocene methanol, ferricyanide, and dopamine). Our findings highlighted that when electrodes were normalised for the geometric surface area of the electrode, the surface pattern of the electrode surface can impact the observed current and electron transfer kinetics. Electrodes that had a dome and flag pattern on the electrode surface showed the highest oxidation currents and had lower values for the difference between the anodic and cathodic peak current (ΔE). However, designs with rings had lower current values and higher ΔE values. These differences are most likely due to variations in the accessibility of conductive sites on the electrode surface due to the varying surface roughness of different patterned designs. Our findings highlight that when making electrodes using 3D printing, surface patterning of the electrode surface can be used as an effective approach to enhance the performance of the sensor for varying applications.

4.
ACS Appl Mater Interfaces ; 16(5): 6569-6578, 2024 Feb 07.
Article in English | MEDLINE | ID: mdl-38261552

ABSTRACT

In the era of the internet of things, there exists a pressing need for technologies that meet the stringent demands of wearable, self-powered, and seamlessly integrated devices. Current approaches to developing MXene-based electrochemical sensors involve either rigid or opaque components, limiting their use in niche applications. This study investigates the potential of pristine Ti3C2Tx electrodes for flexible and transparent electrochemical sensing, achieved through an exploration of how material characteristics (flake size, flake orientation, film geometry, and uniformity) impact the electrochemical activity of the outer sphere redox probe ruthenium hexamine using cyclic voltammetry. The optimized electrode made of stacked large Ti3C2Tx flakes demonstrated excellent reproducibility and resistance to bending conditions, suggesting their use for reliable, robust, and flexible sensors. Reducing electrode thickness resulted in an amplified faradaic-to-capacitance signal, which is advantageous for this application. This led to the deposition of transparent thin Ti3C2Tx films, which maintained their best performance up to 73% transparency. These findings underscore its promise for high-performance, tailored sensors, marking a significant stride in advancing MXene utilization in next-generation electrochemical sensing technologies. The results encourage the analytical electrochemistry field to take advantage of the unique properties that pristine Ti3C2Tx electrodes can provide in sensing through more parametric studies.

5.
J Appl Microbiol ; 134(6)2023 Jun 01.
Article in English | MEDLINE | ID: mdl-37296327

ABSTRACT

AIMS: The care of patients undergoing long-term urethral catheterization is frequently complicated by Proteus mirabilis infection. This organism forms dense, crystalline biofilms, which block catheters leading to serious clinical conditions. However, there are currently no truly effective approaches to control this problem. Here, we describe the development of a novel theranostic catheter coating, to simultaneously provide early warning of blockage, and actively delay crystalline biofilm formation. METHODS AND RESULTS: The coating comprises of a pH sensitive upper polymer layer (poly(methyl methacrylate-co-methacrylic acid); Eudragit S 100®) and a hydrogel base layer of poly(vinyl alcohol), which is loaded with therapeutic agents (acetohydroxamic acid or ciprofloxacin hydrochloride) and a fluorescent dye, 5(6)-carboxyfluorescein (CF). The elevation of urinary pH due to P. mirabilis urease activity results in the dissolution of the upper layer and release of cargo agents contained in the base layer. Experiments using in vitro models, which were representative of P. mirabilis catheter-associated urinary tract infections, demonstrated that these coatings significantly delay time taken for catheters to block. Coatings containing both CF dye and ciprofloxacin HCl were able to provide an average of ca. 79 h advanced warning of blockage and extend catheter lifespan ca. 3.40-fold. CONCLUSIONS: This study has demonstrated the potential for theranostic, infection-responsive coatings to form a promising approach to combat catheter encrustation and actively delay blockage.


Subject(s)
Proteus Infections , Urinary Tract Infections , Humans , Urinary Catheters , Urinary Catheterization/adverse effects , Proteus Infections/prevention & control , Proteus Infections/etiology , Proteus mirabilis , Urinary Tract Infections/prevention & control , Biofilms
6.
ACS Sens ; 8(2): 712-720, 2023 02 24.
Article in English | MEDLINE | ID: mdl-36749605

ABSTRACT

Common symptoms of food intolerance are caused by chemical components within food that have a pharmacological activity to alter the motility of the gastrointestinal tract. Food intolerance is difficult to diagnose as it requires a long-term process of eliminating foods that are responsible for gastrointestinal symptoms. Enterochromaffin (EC) cells are key intestinal epithelium cells that respond to luminal chemical stimulants by releasing 5-HT. Changes in 5-HT levels have been shown to directly alter the motility of the intestinal tract. Therefore, a rapid approach for monitoring the impact of chemicals in food components on 5-HT levels can provide a personalized insight into food intolerance and help stratify diets. Within this study, we developed a three-dimensional (3D)-printed electrochemical multiwell plate to determine changes in 5-HT levels from intestinal organoids that were exposed to varying chemical components found in food. The carbon black/poly-lactic acid (CB/PLA) electrodes had a linear range in physiological concentrations of 5-HT (0.1-2 µM) with a limit of detection of 0.07 µM. The electrodes were stable for monitoring 5-HT overflow from intestinal organoids. Using the electrochemical multiwell plate containing intestinal organoids, increases in 5-HT were observed in the presence of 0.1 mM cinnamaldehyde and 10 mM quercetin but reduction in 5-HT levels was observed in 1 mM sorbitol when compared to control. These changes in the presence of chemicals commonly found in food were verified with ex vivo ileum tissue measurements using chromatography and amperometry with boron-doped diamond electrodes. Overall, our 3D electrochemical multiwell plate measurements with intestinal organoids highlight an approach that can be a high-throughput platform technology for rapid screening of food intolerance to provide personalized nutritional diet.


Subject(s)
Food Intolerance , Serotonin , Humans , Serotonin/analysis , Ileum/chemistry , Intestinal Mucosa/chemistry , Organoids/chemistry
7.
Sci Rep ; 13(1): 339, 2023 Jan 07.
Article in English | MEDLINE | ID: mdl-36611084

ABSTRACT

3D printing provides a reliable approach for the manufacture of carbon thermoplastic composite electrochemical sensors. Many studies have explored the impact of printing parameters on the electrochemical activity of carbon thermoplastic electrodes but limited is known about the influence of instrument parameters, which have been shown to alter the structure and mechanical strength of 3D printed thermoplastics. We explored the impact of extruder temperature, nozzle diameter and heated bed temperature on the electrochemical activity of carbon black/poly-lactic acid (CB/PLA) electrodes. Cyclic voltammetry and electrochemical impedance spectroscopy measurements were conducted using standard redox probes. The electrode surface and cross-section of the electrode was visualised using scanning electron microscopy. We found that using extruder temperatures of 230 °C and 240 °C improved the electrochemical activity of CB/PLA electrodes, due to an increase in surface roughness and a reduction in the number of voids in-between print layers. Nozzle diameter, heated bed temperature of different 3D printers did not impact the electrochemical activity of CB/PLA electrodes. However high-end printers provide improved batch reproducibility of electrodes. These findings highlight the key instrument parameters that need to be considered when manufacturing carbon thermoplastic composite electrochemical sensors when using 3D printing.

8.
Chembiochem ; 24(2): e202200334, 2023 01 17.
Article in English | MEDLINE | ID: mdl-36394122

ABSTRACT

Electrochemical arrays were used to measure the overflow of serotonin (5-HT) and melatonin (MEL) from the entire colon of healthy mice and mice with chemical-induced inflammatory bowel disease (IBD), to understand the interplay between inflammation and colonic function. We show that 5-HT overflow is increased, whilst MEL levels are reduced, in inflamed tissues. The levels of MEL are increased at the interface between healthy and inflamed regions within the colon and may limit the spread of inflammation. Understanding the interplay between inflammation and mucosal epithelial signalling can provide key insight into colonic function and aid the development of effective therapeutic strategies to treat gastrointestinal diseases.


Subject(s)
Melatonin , Serotonin , Mice , Animals , Intestinal Mucosa , Inflammation , Epithelium
9.
Nat Rev Chem ; 6(4): 237-238, 2022 04.
Article in English | MEDLINE | ID: mdl-37117869

Subject(s)
Occupations , Software
10.
Anal Methods ; 13(44): 5335-5342, 2021 11 18.
Article in English | MEDLINE | ID: mdl-34730129

ABSTRACT

There has been a recent surge in the amount of substandard and falsified clopidogrel. Pharmacopeial based assays using high performance liquid chromatography and mass spectroscopy are widely used for the measurement of clopidogrel but are not accessible in low to middle income countries. Therefore, our study explored four different techniques (mid-infrared spectroscopy, thin layer chromatography, ultraviolet visible spectroscopy, and differential pulse voltammetry), which could be used in low to middle income countries. Differential pulse voltammetry showed the best performance for accurate and precise determination of clopidogrel in the presence of excipients. Clopidogrel tablets were fully crushed and sonicated in buffer for 30 seconds prior to differential pulse voltammetry measurements using a 3 mm glassy carbon electrode. Measurements were made without removing the excipients and the limit of detection was 0.08 mg ml-1 and the sensitivity was 15.7 µA mg ml-1. When conducting a blinded study, differential pulse voltammetry was able to identify varying types of substandard and falsified samples. Our findings highlight that voltammetry could be a vital analytical technique for the determination of substandard and falsified medicines in low- and middle-income countries.


Subject(s)
Clopidogrel , Counterfeit Drugs , Excipients , Chromatography, Thin Layer , Clopidogrel/analysis , Counterfeit Drugs/analysis , Electrodes
11.
Angew Chem Int Ed Engl ; 60(44): 23552-23556, 2021 10 25.
Article in English | MEDLINE | ID: mdl-34363735

ABSTRACT

Electrochemical methods were used to explore the exocytotic nature of serotonin (5-HT) release in human carcinoid BON cells, an in vitro human enterochromaffin cell model, to understand the mechanisms operating the release of gut-derived 5-HT in the intestinal mucosal epithelium. We show that the fractional vesicular 5-HT release in BON cells is 80 % compared to previous work in pancreatic beta cells (34 %). The fractional release increased from 80 % in control BON cells to 87 % with 5-HT preincubation and nearly 100 % with the combination of 5-HT and the 5-HT4 autoreceptor agonist, cisapride. Thus, partial release is the primary mechanism of exocytosis in BON cells, resulting in a variable amount of the vesicular content being released. Factors that control secretion of 5-HT from enterochromaffin cells or BON cells are important as partial release provides a mechanism for development of effective therapeutic strategies to treat gastrointestinal diseases.


Subject(s)
Electrochemical Techniques , Enterochromaffin Cells/drug effects , Nanotechnology , Serotonin/pharmacology , Drug Liberation , Exocytosis/drug effects , Gastrointestinal Diseases/drug therapy , Humans , Serotonin/chemistry
12.
Annu Rev Anal Chem (Palo Alto Calif) ; 14(1): 47-63, 2021 07 27.
Article in English | MEDLINE | ID: mdl-33974807

ABSTRACT

Three-dimensional (3D) printing has recently emerged as a novel approach in the development of electrochemical sensors. This approach to fabrication has provided a tremendous opportunity to make complex geometries of electrodes at high precision. The most widely used approach for fabrication is fused deposition modeling; however, other approaches facilitate making smaller geometries or expanding the range of materials that can be printed. The generation of complete analytical devices, such as electrochemical flow cells, provides an example of the array of analytical tools that can be developed. This review highlights the fabrication, design, preparation, and applications of 3D printed electrochemical sensors. Such developments have begun to highlight the vast potential that 3D printed electrochemical sensors can have compared to other strategies in sensor development.

13.
Eur J Neurosci ; 53(5): 1394-1411, 2021 03.
Article in English | MEDLINE | ID: mdl-33131114

ABSTRACT

Ageing is associated in many organisms with a reduction in motor movements. We have previously shown that the rate of feeding movements of the pond snail, Lymnaea, decreased with age but the underlying cause is not fully understood. Here, we show that dopamine in the cerebro-buccal complex is an important signalling molecule regulating feeding frequency in Lymnaea and that ageing is associated with a decrease in CNS dopamine. A proteomic screen of young and old CNSs highlighted a group of proteins that regulate stress responses. One of the proteins identified was 14-3-3, which can enhance the synthesis of dopamine. We show that the Lymnaea 14-3-3 family exists as three distinct isoforms. The expression of the 29 kDa isoform (14-3-3Lym3) in the cerebro-buccal complex decreased with age and correlated with feeding rate. Using a 14-3-3 antagonist (R18) we were able to reduce the synthesis of L-DOPA and dopamine in ex vivo cerebro-buccal complexes. Together these data suggest that an age-related reduction in 14-3-3 can decrease CNS dopamine leading to a consequential reduction in feeding rate.


Subject(s)
Dopamine , Lymnaea , Animals , Central Nervous System , Feeding Behavior , Proteomics
14.
Molecules ; 26(1)2020 Dec 23.
Article in English | MEDLINE | ID: mdl-33374496

ABSTRACT

The development of low-cost electrode devices from conductive materials has recently attracted considerable attention as a sustainable means to replace the existing commercially available electrodes. In this study, two different electrode surfaces (surfaces 1 and 2, denoted as S1 and S2) were fabricated from chocolate wrapping aluminum foils. Energy dispersive X-Ray (EDX) and field emission scanning electron microscopy (FESEM) were used to investigate the elemental composition and surface morphology of the prepared electrodes. Meanwhile, cyclic voltammetry (CV), chronoamperometry, electrochemical impedance spectroscopy (EIS), and differential pulse voltammetry (DPV) were used to assess the electrical conductivities and the electrochemical activities of the prepared electrodes. It was found that the fabricated electrode strips, particularly the S1 electrode, showed good electrochemical responses and conductivity properties in phosphate buffer (PB) solutions. Interestingly, both of the electrodes can respond to the ruthenium hexamine (Ruhex) redox species. The fundamental results presented from this study indicate that this electrode material can be an inexpensive alternative for the electrode substrate. Overall, our findings indicate that electrodes made from chocolate wrapping materials have promise as electrochemical sensors and can be utilized in various applications.


Subject(s)
Aluminum/chemistry , Chocolate , Electrochemical Techniques/methods , Electrodes , Graphite/chemistry , Metals/chemistry , Recycling/methods , Oxidation-Reduction , Surface Properties
15.
Arch Dis Child ; 105(4): 390-394, 2020 04.
Article in English | MEDLINE | ID: mdl-31471281

ABSTRACT

OBJECTIVE: To evaluate whether changing dopamine infusions every 12 hours and preparing these infusions 30 min before administration reduces blood pressure fluctuations in preterm and term neonates. DESIGN: This was a retrospective study using data from live patients on the neonatal unit and prospective study exploring stability of infusions in a laboratory-based neonatal ward simulation. SETTING: Single-centre study in a tertiary neonatal surgical unit in a university teaching hospital. PATIENTS: Neonates who received more than one subsequent dopamine infusion and had invasive arterial blood pressure monitoring, during their admission in the neonatal unit, were included. INTERVENTIONS: As part of the Quality Improvement project, the standard operating procedure (SOP) was changed, and dopamine infusions were prepared by nursing staff and left to rest for 30 min before administering to the neonate. Additionally, infusions were replaced every 12 hours. MAIN OUTCOME MEASURES: The percentage change in mean arterial pressure (MAP) and the percentage loss in the drug concentration during infusion during changeover. RESULTS: Our findings indicate that up to 15% of the initial dopamine concentration is lost after 24 hours. This results in a sharp variation in the dopamine concentration during infusion changeover that correlates with observed rapid fluctuations in MAP. In changing the SOP, no significant difference in the concentration of dopamine and MAP were observed over 12 hours. CONCLUSIONS: Delaying administration of dopamine infusions by 30 min after preparation combined with changing infusions 12 hourly has reduced MAP fluctuations. Therefore, the risks associated with MAP fluctuations, including intraventricular haemorrhages, are reduced.


Subject(s)
Arterial Pressure/drug effects , Blood Pressure/drug effects , Dopamine/administration & dosage , Hypotension/drug therapy , Intensive Care, Neonatal , Dopamine/pharmacology , Female , Hemodynamics , Humans , Hypotension/physiopathology , Infant, Newborn , Infusions, Intravenous , Male , Prospective Studies , Retrospective Studies
16.
Analyst ; 144(20): 6011-6018, 2019 Oct 07.
Article in English | MEDLINE | ID: mdl-31538156

ABSTRACT

Serotonin and kynurenine are formed following metabolism of the essential amino acid tryptophan. Both molecules play important biological roles and the balance of how tryptophan metabolism varies to either the serotonin or kynurenine pathway may provide key insight into the inflammatory status of the biological region. At present complex chromatographic methods are utilised which predominately focus on either monitoring analytes in the serotonin or kynurenine pathway rather than both. Our study develops a simple yet robust methodology for the monitoring of tryptophan metabolism. We utilised isocratic reverse phase high-performance liquid chromatography with simultaneously dual electrochemical detection. This approach allowed for separation of co-eluted analytes and identification of analytes from both pathways within 14 minutes. For all analytes, limits of detection were <35 nM. No crosstalk was observed when dual simultaneous detection was conducted in a radial flow cell. Responses from the hippocampus, blood and ileum mucosa highlighted that each region had a varying ratio of serotonin to kynurenine pathway, indicating varied approaches to tryptophan metabolism. The developed method can monitor how the metabolism of tryptophan varies between the two pathways which can provide insight into the inflammatory state of reach region with age and disease.


Subject(s)
Blood/metabolism , Hippocampus/metabolism , Ileum/metabolism , Tryptophan/metabolism , Animals , Chromatography, High Pressure Liquid , Electrochemical Techniques , Kynurenine/metabolism , Male , Mice , Mice, Inbred C57BL , Serotonin/metabolism
17.
Sci Rep ; 8(1): 9135, 2018 Jun 14.
Article in English | MEDLINE | ID: mdl-29904165

ABSTRACT

Additive manufacturing also known as 3D printing is being utilised in electrochemistry to reproducibly develop complex geometries with conductive properties. In this study, we explored if the electrochemical behavior of 3D printed acrylonitrile butadiene styrene (ABS)/carbon black electrodes was influenced by printing direction. The electrodes were printed in both horizontal and vertical directions. The horizsontal direction resulted in a smooth surface (HPSS electrode) and a comparatively rougher surface (HPRS electrode) surface. Electrodes were characterized using cyclic voltammetry, electrochemical impedance spectroscopy and chronoamperometry. For various redox couples, the vertical printed (VP) electrode showed enhanced current response when compared the two electrode surfaces generated by horizontal print direction. No differences in the capacitive response was observed, indicating that the conductive surface area of all types of electrodes were identical. The VP electrode had reduced charge transfer resistance and uncompensated solution resistance when compared to the HPSS and HPRS electrodes. Overall, electrodes printed in a vertical direction provide enhanced electrochemical performance and our study indicates that print orientation is a key factor that can be used to enhance sensor performance.

18.
Environ Toxicol Pharmacol ; 61: 24-29, 2018 Jul.
Article in English | MEDLINE | ID: mdl-29807310

ABSTRACT

The influence of prenatal alcohol exposure on the serotoninergic system in the brain has been well studied, however its influence on the serotoninergic system in the gastrointestinal system remains unknown. The objective of the study was to use a mouse model of prenatal alcohol exposure to investigate the effects on serotonin and its metabolites and precursors in colonic tissue. This study used treatment of mouse breeding harems with 5% ethanol with saccharin via drinking water throughout pregnancy and compared the results with a saccharin control group. Tryptophan, serotonin (5-HT) and 5- hydroxyindoleacetic acid (5-HIAA) concentrations were measured in the longitudinal muscle myenteric plexus (LMMP) and mucosa of intestinal tissue by high-performance liquid chromatography (HPLC). Decreased 5-HT concentrations in mucosa and LMMP (females only) were observed in prenatally exposed mice compared to controls. Increases in mucosal and LMMP tryptophan concentration were only observed in prenatally exposed female mice. In conclusion, prenatal alcohol exposure causes a decrease in conversion of tryptophan to 5-HT in both muscle and mucosa although the effect is more pronounced in females. The observed sex difference may be related to changes associated with the estrous cycle.


Subject(s)
Ethanol/toxicity , Intestinal Mucosa/drug effects , Myenteric Plexus/drug effects , Prenatal Exposure Delayed Effects , Serotonin/metabolism , Animals , Female , Hydroxyindoleacetic Acid/metabolism , Intestinal Mucosa/metabolism , Male , Mice, Inbred C57BL , Myenteric Plexus/metabolism , Pregnancy , Sex Characteristics , Tryptophan/metabolism
SELECTION OF CITATIONS
SEARCH DETAIL
...