1.
AAPS J ; 14(4): 915-24, 2012 Dec.
Article in English | MEDLINE | ID: mdl-22972221

ABSTRACT

Highly variable (HV) drugs are defined as those for which within-subject variability (%CV) in bioequivalence (BE) measures is 30% or greater. Because of this high variability, studies designed to show whether generic HV drugs are bioequivalent to their corresponding HV reference drugs may need to enroll large numbers of subjects even when the products have no significant mean differences. To avoid unnecessary human testing, the US Food and Drug Administration's Office of Generic Drugs developed a reference-scaled average bioequivalence (RSABE) approach, whereby the BE acceptance limits are scaled to the variability of the reference product. For an acceptable RSABE study, an HV generic drug product must meet the scaled BE limit and a point estimate constraint. The approach has been implemented successfully. To date, the RSABE approach has supported four full approvals and one tentative approval of HV generic drug products.


Subject(s)
Drug Approval/methods , Drugs, Generic/pharmacokinetics , Pharmaceutical Preparations/metabolism , Drugs, Generic/standards , Humans , Pharmaceutical Preparations/standards , Therapeutic Equivalency , United States , United States Food and Drug Administration
2.
Ann Pharmacother ; 43(10): 1583-97, 2009 Oct.
Article in English | MEDLINE | ID: mdl-19776300

ABSTRACT

BACKGROUND: In the US, manufacturers seeking approval to market a generic drug product must submit data demonstrating that the generic formulation provides the same rate and extent of absorption as (ie, is bioequivalent to) the innovator drug product. Thus, most orally administered generic drug products in the US are approved based on results of one or more clinical bioequivalence studies. OBJECTIVE: To evaluate how well the bioequivalence measures of generic drugs approved in the US over a 12-year period compare with those of their corresponding innovator counterparts. METHODS: This retrospective analysis compared the generic and innovator bioequivalence measures from 2070 single-dose clinical bioequivalence studies of orally administered generic drug products approved by the Food and Drug Administration (FDA) from 1996 to 2007 (12 y). Bioequivalence measures evaluated were drug peak plasma concentration (C(max)) and area under the plasma drug concentration versus time curve (AUC), representing drug rate and extent of absorption, respectively. The generic/innovator C(max) and AUC geometric mean ratios (GMRs) were determined from each of the bioequivalence studies, which used from 12 to 170 subjects. The GMRs from the 2070 studies were averaged. In addition, the distribution of differences between generic means and innovator means was determined for both C(max) and AUC. RESULTS: The mean +/- SD of the GMRs from the 2070 studies was 1.00 +/- 0.06 for C(max) and 1.00 +/- 0.04 for AUC. The average difference in C(max) and AUC between generic and innovator products was 4.35% and 3.56%, respectively. In addition, in nearly 98% of the bioequivalence studies conducted during this period, the generic product AUC differed from that of the innovator product by less than 10%. CONCLUSIONS: The criteria used to evaluate generic drug bioequivalence studies support the FDA's objective of approving generic drug formulations that are therapeutically equivalent to their innovator counterparts.


Subject(s)
Drug Approval/legislation & jurisprudence , Drugs, Generic/pharmacokinetics , Pharmaceutical Preparations/administration & dosage , Administration, Oral , Area Under Curve , Clinical Trials as Topic , Drugs, Generic/economics , Humans , Pharmaceutical Preparations/economics , Pharmaceutical Preparations/metabolism , Retrospective Studies , Therapeutic Equivalency , United States , United States Food and Drug Administration
3.
AAPS J ; 10(1): 148-56, 2008.
Article in English | MEDLINE | ID: mdl-18446515

ABSTRACT

INTRODUCTION: It is widely believed that acceptable bioequivalence studies of drugs with high within-subject pharmacokinetic variability must enroll higher numbers of subjects than studies of drugs with lower variability. We studied the scope of this issue within US generic drug regulatory submissions. MATERIALS AND METHODS: We collected data from all in vivo bioequivalence studies reviewed at FDA's Office of Generic Drugs (OGD) from 2003-2005. We used the ANOVA root mean square error (RMSE) from bioequivalence statistical analyses to estimate within-subject variability. A drug was considered highly variable if its RMSE for C (max) and/or AUC was > or =0.3. To identify factors contributing to high variability, we evaluated drug substance pharmacokinetic characteristics and drug product dissolution performance. RESULTS AND DISCUSSION: In 2003-2005, the OGD reviewed 1,010 acceptable bioequivalence studies of 180 different drugs, of which 31% (57/180) were highly variable. Of these highly variable drugs, 51%, 10%, and 39% were either consistently, borderline, or inconsistently highly variable, respectively. We observed that most of the consistent and borderline highly variable drugs underwent extensive first pass metabolism. Drug product dissolution variability was high for about half of the inconsistently highly variable drugs. We could not identify factors causing variability for the other half. Studies of highly variable drugs generally used more subjects than studies of lower variability drugs. CONCLUSION: About 60% of the highly variable drugs we surveyed were highly variable due to drug substance pharmacokinetic characteristics. For about 20% of the highly variable drugs, it appeared that formulation performance contributed to the high variability.


Subject(s)
Drug Approval/methods , Drugs, Generic/pharmacokinetics , Drugs, Generic/standards , United States Food and Drug Administration , Clinical Trials as Topic/methods , Clinical Trials as Topic/standards , Humans , Therapeutic Equivalency , United States