Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Sex Transm Infect ; 86(7): 532-6, 2010 Dec.
Article in English | MEDLINE | ID: mdl-20656720

ABSTRACT

OBJECTIVE: The development of a rapid immunofiltration (flow-through) test for the simultaneous detection of non-treponemal and treponemal antibodies in the serum of patients with syphilis. METHODS: The assay is rapid, inexpensive, and requires limited expertise in interpreting the results. The test is based on the principle of immunofiltration, with two antigens and control material spotted on the membrane of a through-flow device. A positive test is characterised by the appearance of three red/magenta spots within 2-10 min. RESULTS: A total of 376 banked serum samples obtained from the Georgia Public Health Laboratory was examined by the flow-through test, the rapid plasma reagin (RPR) test and the Treponema pallidum passive particle agglutination assay (TPPA). The sensitivity and specificity of the non-treponemal spot were 96.5% and 97.7%, respectively, when compared with the RPR test, and the sensitivity and specificity of the treponemal test spot were 97.3% and 99.1% when compared with the TPPA test. In addition, the test yielded equivalent results to those obtained in comparator tests when 104 sera from cases of syphilis of known stage, 49 sera from diseases other than syphilis and 23 sera known to exhibit biological false-positive reactions were tested in parallel. CONCLUSIONS: These results indicate that the dual treponemal and non-treponemal assay could be used as a screen and confirmatory test for the serological diagnosis of syphilis in remote or resource-poor settings where there is a need to provide counselling and treatment at the initial consultation.


Subject(s)
Antibodies, Bacterial/blood , Syphilis Serodiagnosis/instrumentation , Syphilis/diagnosis , Treponema pallidum/isolation & purification , Equipment Design , Filtration , Humans , Immunoassay/methods , Point-of-Care Systems , Sensitivity and Specificity , Treponema pallidum/immunology
2.
Indian J Exp Biol ; 28(12): 1118-23, 1990 Dec.
Article in English | MEDLINE | ID: mdl-2099326

ABSTRACT

Entamoeba histolytica soluble crude antigen was fractionated by gel filtration on Sephacryl S-300 into four fractions, viz. F1(669 kDa); F2(51.2 kDa); F3(25.1 kDa) and F4(10.5 kDa). F1 fraction was observed to be more sensitive and specific for the detection of antibody in amoebiasis than the crude and other fractions of purified antigens employing IHAT and ELISA. ELISA was found to be better than IHAT since it could detect antibody in the sera (3/6) of asymptomatic cyst passers. The cross reaction of crude antigen with toxocariasis (1/4) and toxoplasmosis (2/5) sera were associated with F4 fraction. F3 and F4 were having low molecular weight and were not sensitive in detection of antibody in amoebiasis. Biochemical characterization revealed glycoprotein nature of the specific (F1) antigen fraction.


Subject(s)
Antigens, Protozoan/isolation & purification , Entamoeba histolytica/immunology , Entamoebiasis/diagnosis , Animals , Humans
3.
Indian J Exp Biol ; 28(7): 671-5, 1990 Jul.
Article in English | MEDLINE | ID: mdl-2272654

ABSTRACT

A simple, sensitive and stable ELISA (enzyme linked immunosorbent assay) was developed using rabbit antibody to fractionated Entamoeba histolytica antigen for the detection of copro antigen in the faeces of individuals with intestinal amoebiasis. In this test none of the healthy individuals, all trophozoite positive, 40% cyst passers and 6% individuals living in endemic area showed the presence of copro antigen. ELISA using polyclonal rabbit antibody could detect 1-5 trophozoites/well and 20-50 ng protein per well of NIH-200 strain of E. histolytica and the sensitivity of the test was comparable with that using monoclonal antibody. Cross reaction was observed only with E. invadens when faeces having other parasites were screened. The reagents of ELISA were stabilized and found to be stable for more than 6 months when stored at 4 degrees C.


Subject(s)
Antigens, Protozoan/analysis , Dysentery, Amebic/immunology , Enzyme-Linked Immunosorbent Assay/methods , Animals , Antibodies, Protozoan/immunology , Cross Reactions , Entamoeba/immunology , Entamoeba histolytica/immunology , Feces , Humans , Rabbits
SELECTION OF CITATIONS
SEARCH DETAIL
...