A A Case Rep ; 9(1): 16-19, 2017 Jul 01.
Article in English | MEDLINE | ID: mdl-28410259

ABSTRACT

An elderly male presented for emergent repair of a ruptured abdominal aortic aneurysm. For anticipated volume resuscitation, vasopressor administration, and hemodynamic monitoring, a large-bore central venous catheter was placed in the left internal jugular vein under ultrasound guidance before surgical incision. Initially, there were no readily apparent signs of venous perforation. However, a massive left hemothorax developed because of perforation of the brachiocephalic vein and violation of the pleural space. This case report discusses both prevention and management of such a complication.


Subject(s)
Brachiocephalic Veins/injuries , Catheterization, Central Venous/adverse effects , Catheterization, Central Venous/instrumentation , Central Venous Catheters , Hemothorax/etiology , Jugular Veins , Vascular System Injuries/etiology , Aged, 80 and over , Brachiocephalic Veins/diagnostic imaging , Hemothorax/diagnostic imaging , Hemothorax/therapy , Humans , Jugular Veins/diagnostic imaging , Male , Phlebography , Treatment Outcome , Vascular System Injuries/diagnostic imaging , Vascular System Injuries/therapy