Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J AOAC Int ; 96(6): 1273-80, 2013.
Article in English | MEDLINE | ID: mdl-24645504

ABSTRACT

A simple, precise, and rapid RPLC method has been developed without incorporation of any ion-pair reagent for the simultaneous determination of vitamin C (C) and seven B-complex vitamins, viz, thiamine hydrochloride (B1), pyridoxine hydrochloride (B6), nicotinamide (B3), cyanocobalamine (B12), folic acid, riboflavin (B2), and 4-aminobenzoic acid (Bx). Separations were achieved within 12.0 min at 30 degrees C by gradient elution on an RP C18 column using a mobile phase consisting of a mixture of 15 mM ammonium formate buffer and 0.1% triethylamine adjusted to pH 4.0 with formic acid and acetonitrile. Simultaneous UV detection was performed at 275 and 360 nm. The method was validated for system suitability, LOD, LOQ, linearity, precision, accuracy, specificity, and robustness in accordance with International Conference on Harmonization guidelines. The developed method was implemented successfully for determination of the aforementioned vitamins in pharmaceutical formulations containing an individual vitamin, in their multivitamin combinations, and in human urine samples. The calibration curves for all analytes showed good linearity, with coefficients of correlation higher than 0.9998. Accuracy, intraday repeatability (n = 6), and interday repeatability (n = 7) were found to be satisfactory.


Subject(s)
Ascorbic Acid/analysis , Ascorbic Acid/urine , Chromatography, Liquid/methods , Vitamin B Complex/analysis , Vitamin B Complex/urine , Vitamins/urine , 4-Aminobenzoic Acid/urine , Calibration , Folic Acid/urine , Humans , Hydrogen-Ion Concentration , Mass Spectrometry , Niacinamide/urine , Pyridoxine/urine , Riboflavin/urine , Sensitivity and Specificity , Solubility , Spectrophotometry, Ultraviolet , Thiazoles/urine , Urinalysis/methods , Vitamin B 12/urine , Vitamins/analysis , Water/chemistry
2.
J AOAC Int ; 95(1): 74-83, 2012.
Article in English | MEDLINE | ID: mdl-22468344

ABSTRACT

A rapid, simple, and accurate ion-pair RPLC method has been developed for simultaneous analysis of vitamin C and major B-complex vitamins. An RP C18 column thermostated at 30 degrees C was used with gradient elution of mobile phase comprising 10 mM potassium dihydrogen phosphate buffer (containing 3 mM sodium hexane-1-sulfonate, adjusted to pH 2.80 with o-phosphoric acid) and methanol at a flow rate of 1.0 mL/min to achieve the best possible separation and resolution of all vitamins in about 11.00 min. The detection was performed at 274 nm. The method has been implemented successfully for simultaneous determination of vitamins present in 12 multivitamin/multimineral pharmaceutical preparations, as well as in human urine. Typical validation characteristics were evaluated in accordance with International Conference on Harmonization guidelines. Good linearity over the investigated concentration levels was observed. Intraday repeatability was < or = 2.0%, and interday variation was < or = 2.6%, for all vitamins. The method can be used for assay of these vitamins over a wide concentration range with good precision and accuracy; hence, it would be appropriate for routine QC as well as in clinical analysis.


Subject(s)
Ascorbic Acid/analysis , Vitamin B Complex/analysis , Ascorbic Acid/urine , Calibration , Capsules , Chemistry, Pharmaceutical , Chromatography, High Pressure Liquid , Humans , Indicators and Reagents , Limit of Detection , Reference Standards , Reproducibility of Results , Solutions , Spectrophotometry, Ultraviolet/methods , Tablets , Vitamin B Complex/urine
SELECTION OF CITATIONS
SEARCH DETAIL
...