Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Article in English | MEDLINE | ID: mdl-38886306

ABSTRACT

Acute ischemic stroke occurs when a blood clot occludes a cerebral artery. Mechanical interventions, primarily stent retrievers and aspiration thrombectomy, are used currently for removing the occluding clot and restoring blood flow. Aspiration involves using a long catheter to traverse the cerebral vasculature to reach the blood clot, followed by application of suction through the catheter bore. Aspiration is also used in conjunction with other techniques such as stent retrievers and balloon guide catheters. Despite the wide use of aspiration, our physical understanding of the process and the causes of the failure of aspiration to retrieve cerebral clots in certain scenarios is not well understood. Experimental and computational studies can help develop the capability to provide deeper insights into the procedure and enable development of new devices and more effective treatment methods. We recapitulate the aspiration-based thrombectomy techniques in clinical practice and provide a perspective of existing engineering methods for aspiration. We articulate the current knowledge gap in the understanding of aspiration and highlight possible directions for future engineering studies to bridge this gap, help clinical translation of engineering studies, and develop new patient-specific stroke therapy.

2.
Int J Numer Method Biomed Eng ; 39(2): e3667, 2023 02.
Article in English | MEDLINE | ID: mdl-36511815

ABSTRACT

Acute ischemic stroke, the second leading cause of death worldwide, results from occlusion of a cerebral artery by a blood clot. Application of cyclic aspiration using an aspiration catheter is a current therapy for the removal of lodged clots. In this study, we perform finite element simulations to analyze deformation of long clots, having length to radius ratio of 2-10, which corresponds to clot-length of 2.85-14.25 mm, under peak-to-peak cyclic aspiration pressures of 10-50 mmHg, and frequencies of 0.5, 1, and 2 Hz. Our computational system comprises of a nonlinear viscoelastic solid clot, a hyperelastic artery, and a nonlinear viscoelastic cohesive zone, the latter modeling the clot-artery interface. We observe that clots having length-to-radius ratio approximately greater than two separate from the inner arterial surface somewhere between the axial and distal ends, irrespective of the cyclic aspiration loading conditions. The stress distribution within the clot shows large tensile stresses in the clot interior, indicating the possibility of simultaneous fragmentation of the clot. Thus, this study shows us the various failure mechanisms simultaneously present in the clot during cyclic aspiration. Similarly, the stress distribution within the artery implies a possibility of endothelial damage to the arterial wall near the end where the aspiration pressure is applied. This framework provides a foundation for further investigation to clot fracture and adhesion characterization.


Subject(s)
Ischemic Stroke , Stroke , Thrombosis , Humans , Thrombectomy/methods , Arteries , Stroke/therapy , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...