Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Int J Artif Organs ; 35(6): 435-43, 2012 Jun.
Article in English | MEDLINE | ID: mdl-22669588

ABSTRACT

BACKGROUND: Mixed diffusive-convective dialysis therapies offer greater removal capabilities than conventional dialysis. The aim of this study was to compare two different on-line, post-dilution hemodiafiltration (HDF) treatments with regard to achieved convective volume and middle-molecule dialysis efficiency: standard volume control (sOL-HDF) and automated control of the transmembrane pressure (TMP) (UC-HDF). METHODS: We enrolled 30 ESRD patients (55.9 ± 14.0 years, 20/10 M/F) in a randomized, prospective, cross-over study. The patients received a 3-month period of sOL-HDF followed by UC-HDF for a further 3 months, or vice versa, using the same dialysis machine. In sOL-HDF, fixed exchange volumes were set according to a filtration fraction greater than or equal to 25%. In UC-HDF therapy, the exchanged volume was driven by a biofeedback system controlling the TMP and its set point in a double loop. Patients maintained their treatment time, dialyzer, blood flow rate, and anticoagulant regimen unchanged throughout the study. RESULTS: Greater convective volumes were achieved in UC-HDF than in sOL-HDF (23.8 ± 3.9 vs.19.8 ± 4.8 L; p<0.001) with high pre-dialysis Ht value (sOL-HDF 34.0 ± 4.5% and UC-HDF 34.0 ± 4.4%; p = 0.91). The average clearance values of ß2m and P were higher in UC-HDF than in sOL-HDF (respectively 123 ± 24 vs. 111 ± 22 ml/min, p<0.002 and 158 ± 26 vs. 152 ± 25 ml/min, p<0.05). Moreover, the UC-HDF mode led to a significantly increased rate of call-free sessions from 88% to 97% (p<0.0001). CONCLUSIONS: This study showed that the biofeedback module, applied to the automatic control of TMP in on-line HDF, results in higher convective volumes and correspondingly higher ß2m and P clearances. By making the HDF treatment more automated and less complex to perform, it significantly reduced the staff workload.


Subject(s)
Hemodiafiltration/methods , Kidney Failure, Chronic/therapy , Adult , Aged , Anticoagulants/therapeutic use , Automation , Biomarkers/blood , Cross-Over Studies , Equipment Design , Feedback , Female , Hemodiafiltration/instrumentation , Hemodiafiltration/nursing , Humans , Italy , Kidney Failure, Chronic/blood , Kidney Failure, Chronic/nursing , Male , Membranes, Artificial , Middle Aged , Phosphates/blood , Pressure , Prospective Studies , Time Factors , Treatment Outcome , Workload , beta 2-Microglobulin/blood
SELECTION OF CITATIONS
SEARCH DETAIL
...