Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
BMJ Open Gastroenterol ; 6(1): e000279, 2019.
Article in English | MEDLINE | ID: mdl-31139426

ABSTRACT

OBJECTIVE: Endoanal ultrasound (EAUS) is a recommended preoperative investigation for fistula-in-ano (FiA) which aims to provide the best chance of healing and preservation of continence function. This study aims are (1) to assess effect of EAUS on functional outcome and (2) to determine factors associated with clinical outcomes after FiA surgery. DESIGN: Retrospective analysis of subjects with cryptogenic FiA between January 2011 and December 2016, in a tertiary hospital, was performed by comparing EAUS and no-EAUS groups. Postoperative change in St. Mark's faecal incontinence severity score (cFISS=FISS at 6 months after surgery-FISS before surgery) were compared. General linear model was used to determine factors associated with cFISS. Binary logistic regression was used to assess factors related to clinical outcomes. A p-value of <0.05 is considered significant. RESULTS: We enrolled 339 subjects; 109 (M:F 91:18, mean age 41.7±13.6 years) of 115 in EAUS group and 230 in no-EAUS group (M:F 195:35, mean age 42.6±13.0 years). There were higher proportions of recurrent cases (24.8% vs 13.9%, p=0.014) and complex FiA (80.7% vs 50.4%, p=0.001) in EAUS group. Postoperative FISS (mean±SE) were increased in both groups; preoperative versus postoperative FISS were 0.36±0.20 versus 0.59±0.25 in EAUS group (p=0.056) and 0.31±0.12 versus 0.76±0.17 in no-EAUS group (p<0.001). EAUS had significant effects on cFISS in both univariate analysis, F(1,261)=4.053, p=0.045; and multivariate analysis, F(3,322)=3.147, p=0.025, Wilk's Lambda 0.972. Other associated factors included recurrent fistula (F(3,322)=0.777, p=0.007, Wilk's Lambda 0.993) and fistula classification (F(3,322)=16.978, p<0.001, Wilk's Lambda 0.863). After a mean follow-up of 33.6±28.6 weeks, success rate was 63.3%(EAUS) and 60% (no-EAUS), p=0.822. Factors associated with clinical outcomes were fistula complexity, number of tracts, recurrence, number of previous surgery and type of operations. Accuracy of EAUS was 90.8% and not related to clinical outcomes (p=0.522). CONCLUSION: EAUS had favourable effects on functional outcome after FiA surgery while multiple factors were associated with clinical outcomes. EAUS is useful, accurate, inexpensive and can be the first tool for planning of complex and recurrent FiA.

2.
World J Gastroenterol ; 20(10): 2681-7, 2014 Mar 14.
Article in English | MEDLINE | ID: mdl-24627604

ABSTRACT

AIM: To evaluate feasibility of the novel forward-viewing radial-array echoendoscope for staging of colon cancer beyond rectum as the first series. METHODS: A retrospective study with prospectively entered database. From March 2012 to February 2013, a total of 21 patients (11 men) (mean age 64.2 years) with colon cancer beyond the rectum were recruited. The novel forward-viewing radial-array echoendoscope was used for ultrasonographic staging of colon cancer beyond rectum. Ultrasonographic T and N staging were recorded when surgical pathology was used as a gold standard. RESULTS: The mean time to reach the lesion and the mean time to complete the procedure were 3.5 and 7.1 min, respectively. The echoendoscope passed through the lesions in 13 patients (61.9%) and reached the cecum in 10 of 13 patients (76.9%). No adverse events were found. The lesions were located in the cecum (n = 2), ascending colon (n = 1), transverse colon (n = 2), descending colon (n = 2), and sigmoid colon (n = 14). The accuracy rate for T1 (n = 3), T2 (n = 4), T3 (n = 13) and T4 (n = 1) were 100%, 60.0%, 84.6% and 100%, respectively. The overall accuracy rates for the T and N staging of colon cancer were 81.0% and 52.4%, respectively. The accuracy rates among traversable lesions (n = 13) and obstructive lesions (n = 8) were 61.5% and 100%, respectively. Endoscopic ultrasound and computed tomography had overall accuracy rates of 81.0% and 68.4%, respectively. CONCLUSION: The echoendoscope is a feasible staging tool for colon cancer beyond rectum. However, accuracy of the echoendoscope needs to be verified by larger systematic studies.


Subject(s)
Colon/diagnostic imaging , Colonic Neoplasms/diagnostic imaging , Colonoscopes , Colonoscopy/instrumentation , Endosonography/instrumentation , Neoplasm Staging/instrumentation , Rectum/diagnostic imaging , Adult , Aged , Aged, 80 and over , Colon/pathology , Colonic Neoplasms/pathology , Equipment Design , Feasibility Studies , Female , Humans , Male , Middle Aged , Neoplasm Staging/methods , Predictive Value of Tests , Rectum/pathology , Retrospective Studies
3.
J Med Assoc Thai ; 90(3): 581-6, 2007 Mar.
Article in English | MEDLINE | ID: mdl-17427539

ABSTRACT

OBJECTIVE: To describe a new technique for fistula-in-ano surgery aimed at total sphincter preservation, and evaluate the preliminary results concerning non-healing and intact anal function. MATERIAL AND METHOD: A prospective observational study in eighteen fistula-in-ano patients treated by ligation of intersphincteric fistula tract (LIFT) technique, from January to June 2006. RESULTS: Fistula-in-ano in seventeen patients healed primarily (94.4%). There was one non-healing case (5.6%). The mean healing time was four weeks. None had disturbances in clinical anal continence. CONCLUSION: The early outcome of the LIFT technique is quite impressive. Results warrant a larger study with long-term evaluation. This technique has the potential to become a viable option for fistula-in-ano surgery.


Subject(s)
Rectal Fistula/surgery , Adult , Aged , Anal Canal , Digestive System Surgical Procedures/methods , Female , Humans , Ligation , Male , Middle Aged , Prospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...