Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 51
Filter
1.
Article in English | MEDLINE | ID: mdl-26737747

ABSTRACT

The motion characteristics of the diaphragmatic muscle may provide useful information about normal and abnormal diaphragmatic function and indicate diaphragmatic weakness. The objective of this paper was to introduce a simple system for the quantitative analysis of ultrasonic diaphragmatic motion. The measurements routinely carried out by the experts were computed and these include: (i) excursion, (ii) inspiration time (Tinsp) and (iii) cycle duration (Ttot). The system was evaluated on four simulated videos and one real video. Manual and automated measurements were very close. Further work in a larger number of videos is needed for validating the proposed method.


Subject(s)
Diaphragm/diagnostic imaging , Diaphragm/physiology , Movement/physiology , Humans , Image Processing, Computer-Assisted , Ultrasonography , Video Recording
2.
Article in English | MEDLINE | ID: mdl-26736228

ABSTRACT

This study proposes a unifying framework for m-Health video communication systems that provides for the joint optimization of video quality, bitrate demands, and encoding time. The framework is video modality and infrastructure independent and facilitates adaptation to the best available encoding mode that satisfies underlying technology and application imposed constraints. The scalability of the proposed algorithm is demonstrated using different HEVC encoding configurations and realistic modelling of 802.11× wireless infrastructure for emergency scenery and response videos. Extensive experimentation shows that a jointly optimal solution in the encoding time, bitrate, and video quality space is feasible.


Subject(s)
Disasters , Emergency Medicine/methods , Video Recording/methods , Wireless Technology , Algorithms , Computer Communication Networks , Decision Support Techniques , Humans , Telemedicine/instrumentation , Wireless Technology/instrumentation
3.
Article in English | MEDLINE | ID: mdl-26736267

ABSTRACT

Non-invasive ultrasound imaging of carotid plaques can provide information on the characteristics of the arterial wall including the size, morphology and texture of the atherosclerotic plaques. Several studies were carried out that demonstrated the usefulness of these feature sets for differentiating between asymptomatic and symptomatic plaques and their corresponding cerebrovascular risk stratification. The aim of this study was to develop predictive modelling for estimating the time period of a stroke event by determining the risk for short term (less or equal to three years) or long term (more than three years) events. Data from 108 patients that had a stroke event have been used. The information collected included clinical and ultrasound imaging data. The prediction was performed at base line where patients were still asymptomatic. Several image texture analysis and clinical features were used in order to create a classification model. The different features were statistically analyzed and we conclude that image texture analysis features extracted using Spatial Gray Level Dependencies method had the best statistical significance. Several predictive models were derived based on Binary Logistic Regression (BLR) and Support Vector Machines (SVM) modelling. The best results were obtained with the SVM modelling models with an average correct classifications score of 77±7% for differentiating between stroke event occurrences within 3 years versus more than 3 years. Further work is needed in investigating additional multiscale texture analysis features as well as more modelling techniques on more subjects.


Subject(s)
Carotid Arteries/diagnostic imaging , Plaque, Atherosclerotic/diagnostic imaging , Stroke/diagnosis , Ultrasonography/methods , Carotid Arteries/pathology , Humans , Ischemia/diagnosis , Ischemia/diagnostic imaging , Logistic Models , Plaque, Atherosclerotic/complications , Risk Factors , Sensitivity and Specificity , Stroke/etiology , Support Vector Machine , Time Factors
4.
Annu Int Conf IEEE Eng Med Biol Soc ; 2015: 1401-4, 2015 Aug.
Article in English | MEDLINE | ID: mdl-26736531

ABSTRACT

There is a huge need for open source software solutions in the healthcare domain, given the flexibility, interoperability and resource savings characteristics they offer. In this context, this paper presents the development of three open source libraries - Specific Enablers (SEs) for eHealth applications that were developed under the European project titled "Future Internet Social and Technological Alignment Research" (FI-STAR) funded under the "Future Internet Public Private Partnership" (FI-PPP) program. The three SEs developed under the Electronic Health Record Application Support Service Enablers (EHR-EN) correspond to: a) an Electronic Health Record enabler (EHR SE), b) a patient summary enabler based on the EU project "European patient Summary Open Source services" (epSOS SE) supporting patient mobility and the offering of interoperable services, and c) a Picture Archiving and Communications System (PACS) enabler (PACS SE) based on the dcm4che open source system for the support of medical imaging functionality. The EHR SE follows the HL7 Clinical Document Architecture (CDA) V2.0 and supports the Integrating the Healthcare Enterprise (IHE) profiles (recently awarded in Connectathon 2015). These three FI-STAR platform enablers are designed to facilitate the deployment of innovative applications and value added services in the health care sector. They can be downloaded from the FI-STAR cataloque website. Work in progress focuses in the validation and evaluation scenarios for the proving and demonstration of the usability, applicability and adaptability of the proposed enablers.


Subject(s)
Electronic Health Records , Internet , Radiology Information Systems , Software , Telemedicine
5.
IEEE J Biomed Health Inform ; 19(3): 1129-36, 2015 May.
Article in English | MEDLINE | ID: mdl-24968338

ABSTRACT

The paper presents the development of a computer-aided diagnostic (CAD) system for the early detection of endometrial cancer. The proposed CAD system supports reproducibility through texture feature standardization, standardized multifeature selection, and provides physicians with comparative distributions of the extracted texture features. The CAD system was validated using 516 regions of interest (ROIs) extracted from 52 subjects. The ROIs were equally distributed among normal and abnormal cases. To support reproducibility, the RGB images were first gamma corrected and then converted into HSV and YCrCb. From each channel of the gamma-corrected YCrCb, HSV, and RGB color systems, we extracted the following texture features: 1) statistical features (SFs), 2) spatial gray-level dependence matrices (SGLDM), and 3) gray-level difference statistics (GLDS). The texture features were then used as inputs with support vector machines (SVMs) and the probabilistic neural network (PNN) classifiers. After accounting for multiple comparisons, texture features extracted from abnormal ROIs were found to be significantly different than texture features extracted from normal ROIs. Compared to texture features extracted from normal ROIs, abnormal ROIs were characterized by lower image intensity, while variance, entropy, and contrast gave higher values. In terms of ROI classification, the best results were achieved by using SF and GLDS features with an SVM classifier. For this combination, the proposed CAD system achieved an 81% correct classification rate.


Subject(s)
Hysteroscopy/methods , Image Interpretation, Computer-Assisted/methods , Endometrial Neoplasms/diagnosis , Endometrial Neoplasms/pathology , Female , Humans , Middle Aged , ROC Curve , User-Computer Interface , Uterus/pathology
6.
J Neuroradiol ; 42(2): 99-114, 2015 Apr.
Article in English | MEDLINE | ID: mdl-24970463

ABSTRACT

INTRODUCTION: This study investigates the application of texture analysis methods on brain T2-white matter lesions detected with magnetic resonance imaging (MRI) for the prognosis of future disability in subjects diagnosed with clinical isolated syndrome (CIS) of multiple sclerosis (MS). METHODS: Brain lesions and normal appearing white matter (NAWM) from 38 symptomatic untreated subjects diagnosed with CIS as well as normal white matter (NWM) from 20 healthy volunteers, were manually segmented, by an experienced MS neurologist, on transverse T2-weighted images obtained from serial brain MR imaging scans (0 and 6-12 months). Additional clinical information in the form of the Expanded Disability Status Scale (EDSS), a scale from 0 to 10, which provides a way of quantifying disability in MS and monitoring the changes over time in the level of disability, were also provided. Shape and most importantly different texture features including GLCM and laws were then extracted for all above regions, after image intensity normalization. RESULTS: The findings showed that: (i) there were significant differences for the texture futures extracted between the NAWM and lesions at 0 month and between NAWM and lesions at 6-12 months. However, no significant differences were found for all texture features extracted when comparing lesions temporally at 0 and 6-12 months with the exception of contrast (gray level difference statistics-GLDS) and difference entropy (spatial gray level dependence matrix-SGLDM); (ii) significant differences were found between NWM and NAWM for most of the texture features investigated in this study; (iii) there were significant differences found for the lesion texture features at 0 month for those with EDSS≤2 versus those with EDSS>2 (mean, median, inverse difference moment and sum average) and for the lesion texture features at 6-12 months with EDSS>2 and EDSS≤2 for the texture features (mean, median, entropy and sum average). It should be noted that whilst there were no differences in entropy at time 0 between the two groups, significant change was observed at 6-12 months, relating the corresponding features to the follow-up and disability (EDSS) progression. For the NAWM, significant differences were found between 0 month and 6-12 months with EDSS≤2 (contrast, inverse difference moment), for 6-12 months for EDSS>2 and 0 month with EDSS>2 (difference entropy) and for 6-12 months for EDSS>2 and EDSS≤2 (sum average); (iv) there was no significant difference for NAWM and the lesion texture features (for both 0 and 6-12 months) for subjects with no change in EDSS score versus subjects with increased EDSS score from 2 to 5 years. CONCLUSIONS: The findings of this study provide evidence that texture features of T2 MRI brain white matter lesions may have an additional potential role in the clinical evaluation of MRI images in MS and perhaps may provide some prognostic evidence in relation to future disability of patients. However, a larger scale study is needed to establish the application in clinical practice and for computing shape and texture features that may provide information for better and earlier differentiation between normal brain tissue and MS lesions.


Subject(s)
Demyelinating Diseases/pathology , Diffusion Tensor Imaging/methods , Image Interpretation, Computer-Assisted/methods , Imaging, Three-Dimensional/methods , Multiple Sclerosis/pathology , White Matter/pathology , Adult , Algorithms , Female , Humans , Image Enhancement/methods , Male , Pattern Recognition, Automated/methods , Reproducibility of Results , Sensitivity and Specificity
7.
Int J Biomed Imaging ; 2014: 518414, 2014.
Article in English | MEDLINE | ID: mdl-24734038

ABSTRACT

The intima-media thickness (IMT) of the common carotid artery (CCA) is widely used as an early indicator of cardiovascular disease (CVD). Typically, the IMT grows with age and this is used as a sign of increased risk of CVD. Beyond thickness, there is also clinical interest in identifying how the composition and texture of the intima-media complex (IMC) changed and how these textural changes grow into atherosclerotic plaques that can cause stroke. Clearly though texture analysis of ultrasound images can be greatly affected by speckle noise, our goal here is to develop effective despeckle noise methods that can recover image texture associated with increased rates of atherosclerosis disease. In this study, we perform a comparative evaluation of several despeckle filtering methods, on 100 ultrasound images of the CCA, based on the extracted multiscale Amplitude-Modulation Frequency-Modulation (AM-FM) texture features and visual image quality assessment by two clinical experts. Texture features were extracted from the automatically segmented IMC for three different age groups. The despeckle filters hybrid median and the homogeneous mask area filter showed the best performance by improving the class separation between the three age groups and also yielded significantly improved image quality.

8.
Article in English | MEDLINE | ID: mdl-24111419

ABSTRACT

The emergence of the new, High Efficiency Video Coding (HEVC) standard, combined with wide deployment of 4G wireless networks, will provide significant support toward the adoption of mobile-health (m-health) medical video communication systems in standard clinical practice. For the first time since the emergence of m-health systems and services, medical video communication systems can be deployed that can rival the standards of in-hospital examinations. In this paper, we provide a thorough overview of today's advancements in the field, discuss existing approaches, and highlight the future trends and objectives.


Subject(s)
Computer Communication Networks , Telemedicine/instrumentation , Algorithms , Communication , Diagnosis, Computer-Assisted , Equipment Design , Humans , Signal Processing, Computer-Assisted , Telemedicine/methods , Video Recording , Wireless Technology
9.
Article in English | MEDLINE | ID: mdl-23365830

ABSTRACT

The degree of stenosis of the common carotid artery (CCA) but also the characteristics of the arterial wall including plaque size, composition and elasticity represent important predictors used in the assessment of the risk for future cardiovascular events. This paper proposes and evaluates an integrated system for the segmentation of atherosclerotic carotid plaque in ultrasound video of the CCA based on normalization, speckle reduction filtering (with the hybrid median filter) and parametric active contours. The algorithm is initialized in the first video frame of the cardiac cycle with human assistance and the moving atherosclerotic plaque borders are tracked and segmented in the subsequent frames. The algorithm is evaluated on 10 real CCA digitized videos from B-mode longitudinal ultrasound segments and is compared with the manual segmentations of an expert, for every 20 frames in a time span of 3-5 seconds, covering in general 2 cardiac cycles. The segmentation results are very satisfactory with a true negative fraction (TNF) of 79.3%, a true-positive fraction (TPF) of 78.12%, a false-positive fraction (FPF) of 6.7% and a false-negative fraction (FNF) of 19.6% between the ground truth and the presented plaque segmentations, a Williams index (KI) of 80.3%, an overlap index of 71.5%, a specificity of 0.88±0.09, a precision of 0.86±0.10 and an effectiveness measure of 0.77±0.09. The results show that integrated system investigated in this study could be successfully used for the automated video segmentation of the carotid plaque.


Subject(s)
Carotid Artery Diseases , Carotid Artery, Common , Image Processing, Computer-Assisted/methods , Plaque, Atherosclerotic , Video Recording/methods , Carotid Artery Diseases/diagnostic imaging , Carotid Artery Diseases/physiopathology , Carotid Artery, Common/diagnostic imaging , Carotid Artery, Common/physiopathology , Female , Humans , Male , Plaque, Atherosclerotic/diagnostic imaging , Plaque, Atherosclerotic/physiopathology , Ultrasonography
10.
Article in English | MEDLINE | ID: mdl-23366352

ABSTRACT

Emerging high efficiency video compression methods and wider availability of wireless network infrastructure will significantly advance existing m-health applications. For medical video communications, the emerging video compression and network standards support low-delay and high-resolution video transmission, at the clinically acquired resolution and frame rates. Such advances are expected to further promote the adoption of m-health systems for remote diagnosis and emergency incidents in daily clinical practice. This paper compares the performance of the emerging high efficiency video coding (HEVC) standard to the current state-of-the-art H.264/AVC standard. The experimental evaluation, based on five atherosclerotic plaque ultrasound videos encoded at QCIF, CIF, and 4CIF resolutions demonstrates that 50% reductions in bitrate requirements is possible for equivalent clinical quality.


Subject(s)
Algorithms , Data Compression/methods , Image Interpretation, Computer-Assisted/methods , Signal Processing, Computer-Assisted , Telemedicine/methods , Ultrasonography/methods , Video Recording/methods
11.
IEEE Trans Inf Technol Biomed ; 15(2): 178-88, 2011 Mar.
Article in English | MEDLINE | ID: mdl-20889436

ABSTRACT

The intima-media thickness (IMT) of the common carotid artery (CCA) is widely used as an early indicator of cardiovascular disease (CVD). Clinically, there is strong interest in identifying how the composition and texture of the media layer (ML) can be associated with the risk of stroke. In this study, we use 2-D amplitude-modulation frequency-modulation (AM-FM) analysis of the intima-media complex (IMC), the ML, and intima layer (IL) of the CCA to detect texture changes as a function of age and sex. The study was performed on 100 ultrasound images acquired from asymptomatic subjects at risk of atherosclerosis. To investigate texture variations associated with age, we separated them into three age groups: 1) patients younger than 50; 2) patients aged between 50 and 60 years old; and 3) patients over 60 years old. We also separated the patients by sex. The IMC, ML, and IL were segmented manually by a neurovascular expert and also by a snake-based segmentation system. To reject strong edge artifacts, we prefilter with an AM-FM filterbank that is centered along the horizontal frequency axis (parallel to the long axis of the IMC, ML, and IL), while removing the low-pass filter estimates and frequency bands with large, vertical frequency components. To investigate significant texture changes, we extract the instantaneous amplitude (IA) and the magnitude of the instantaneous frequency (IF) over each layer component, for low-, medium-, and high-frequency AM-FM components. We detected significant texture differences between the higher risk age group of >60 years versus the lower risk age group of <50 and the 50-60 group. In particular, between the <50 and >60 groups, we found significant differences in the medium-scale IA extracted from the IMC. Between the >60 and the 50-60 groups, we found significant texture changes in the low-scale IA and high-scale IF magnitude extracted from the IMC, and the low-scale IA extracted from the IL. Also, we noted that the IA for the ML showed significant differences between males and females for all age groups. The AM--FM features provide complimentary information to classical texture analysis features like the gray-scale median, contrast, and coarseness. These findings provide evidence that AM--FM texture features can be associated with the progression of cardiovascular risk for disease and the risk of stroke with age. However, a larger scale study is needed to establish the application in clinical practice.


Subject(s)
Carotid Arteries/diagnostic imaging , Image Processing, Computer-Assisted/methods , Tunica Intima/diagnostic imaging , Ultrasonography/methods , Adult , Age Factors , Aged , Female , Humans , Male , Middle Aged , Sex Factors
13.
IEEE Trans Inf Technol Biomed ; 15(1): 119-29, 2011 Jan.
Article in English | MEDLINE | ID: mdl-21062681

ABSTRACT

This study introduces the use of multiscale amplitude modulation-frequency modulation (AM-FM) texture analysis of multiple sclerosis (MS) using magnetic resonance (MR) images from brain. Clinically, there is interest in identifying potential associations between lesion texture and disease progression, and in relating texture features with relevant clinical indexes, such as the expanded disability status scale (EDSS). This longitudinal study explores the application of 2-D AM-FM analysis of brain white matter MS lesions to quantify and monitor disease load. To this end, MS lesions and normal-appearing white matter (NAWM) from MS patients, as well as normal white matter (NWM) from healthy volunteers, were segmented on transverse T2-weighted images obtained from serial brain MR imaging (MRI) scans (0 and 6-12 months). The instantaneous amplitude (IA), the magnitude of the instantaneous frequency (IF), and the IF angle were extracted from each segmented region at different scales. The findings suggest that AM-FM characteristics succeed in differentiating 1) between NWM and lesions; 2) between NAWM and lesions; and 3) between NWM and NAWM. A support vector machine (SVM) classifier succeeded in differentiating between patients that, two years after the initial MRI scan, acquired an EDSS ≤ 2 from those with EDSS > 2 (correct classification rate = 86%). The best classification results were obtained from including the combination of the low-scale IA and IF magnitude with the medium-scale IA. The AM-FM features provide complementary information to classical texture analysis features like the gray-scale median, contrast, and coarseness. The findings of this study provide evidence that AM-FM features may have a potential role as surrogate markers of lesion load in MS.


Subject(s)
Brain/pathology , Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Multiple Sclerosis/pathology , Adult , Algorithms , Area Under Curve , Artificial Intelligence , Female , Humans , Male , Statistics, Nonparametric
14.
Article in English | MEDLINE | ID: mdl-22254849

ABSTRACT

In this paper we provide an overview of the way that information and communication technologies have been used for emergency healthcare support. The paper provides a literature review of case studies exploring information systems for monitoring signals, images, medical videos, as well as information protocols used during emergency health care support, and describes future trends. We anticipate that eEmergency systems can significantly improve the delivery of healthcare during emergency cases. However, the monitoring and evaluation of these systems and especially their use in daily practice still remains a goal to be achieved.


Subject(s)
Emergency Medical Services/organization & administration , Information Systems , Clinical Protocols , Monitoring, Physiologic/methods
15.
Article in English | MEDLINE | ID: mdl-21097209

ABSTRACT

Advances in video compression, network technologies, and computer technologies have contributed to the rapid growth of mobile health (m-health) systems and services. Wide deployment of such systems and services is expected in the near future, and it's foreseen that they will soon be incorporated in daily clinical practice. This study focuses in describing the basic components of an end-to-end wireless medical video telemedicine system, providing a brief overview of the recent advances in the field, while it also highlights future trends in the design of telemedicine systems that are diagnostically driven.


Subject(s)
Cell Phone , Computer Communication Networks , Telemedicine/methods , Telemetry/methods , User-Computer Interface , Video Recording/methods , Spain
16.
Article in English | MEDLINE | ID: mdl-19964858

ABSTRACT

In this paper we define diagnostic Regions of Interest (ROIs) for carotid ultrasound medical video, which we then use as input for Flexible Macroblock Ordering (FMO) slice encoding. We extend the FMO concept by enabling variable quality slice encoding, tightly coupled by each region's diagnostic importance. Redundant Slices (RS) utilization increases compressed video's resilience over error prone transmission mediums. We evaluate our scheme on a series of five (5) carotid ultrasound videos at QCIF and CIF resolutions, for packet loss rates up to 30%. Quality assessment based on a clinical rating system that provides for independent evaluations of the different parts of the video (subjective), as well as PSNR ratings (objective), shows that encoded videos attain enhanced diagnostic performance under noisy environments, while at the same time achieving significant bandwidth demands reductions.


Subject(s)
Artifacts , Ultrasonography/instrumentation , Video Recording/instrumentation , Carotid Arteries/diagnostic imaging , Electrocardiography , Evaluation Studies as Topic , Humans , Pliability
17.
Article in English | MEDLINE | ID: mdl-19964506

ABSTRACT

Advances in mobile communications and medical technologies facilitate the development of emerging mobile systems and applications for healthcare. The objective of this paper is to provide an overview and the current status of mobile health care systems (mHealth) and their applications for Emergency healthcare support (eEmergency). Our paper reports on journal papers that use wireless, emergency telemedicine systems that appeared since 2000. The majority of the applications are focused on the transmission of crucial biosignals (mainly ECG) for the support of heart-related healthcare. A limited number of new studies were focused on supporting emergency healthcare for trauma by facilitating both 2D image or video transmission (eg: ultrasound). Alternatively, new studies have focused on integrated systems for specialized emergency scenaria such as stroke. This paper is an extension of work previously published by our group [1].


Subject(s)
Delivery of Health Care/methods , Emergency Medical Services/methods , Telemedicine/methods , Biomedical Engineering , Cell Phone , Computer Communication Networks , Humans , Internet , Remote Consultation
18.
Article in English | MEDLINE | ID: mdl-19965088

ABSTRACT

Although significant progress has been made in the diagnosis and treatment of coronary heart disease (CHD), further investigation is still needed. The objective of this study was to develop a data mining system using association analysis based on the apriori algorithm for the assessment of heart event related risk factors. The events investigated were: myocardial infarction (MI), percutaneous coronary intervention (PCI), and coronary artery bypass graft surgery (CABG). A total of 369 cases were collected from the Paphos CHD Survey, most of them with more than one event. The most important risk factors, as extracted from the association rule analysis were: sex (male), smoking, high density lipoprotein, glucose, family history, and history of hypertension. Most of these risk factors were also extracted by our group in a previous study using the C4.5 decision tree algorithms, and by other investigators. Further investigation with larger data sets is still needed to verify these findings.


Subject(s)
Coronary Artery Disease/diagnosis , Coronary Artery Disease/mortality , Proportional Hazards Models , Age Distribution , Algorithms , Female , Greece/epidemiology , Humans , Incidence , Male , Reproducibility of Results , Risk Assessment/methods , Risk Factors , Sensitivity and Specificity , Sex Distribution
19.
Comput Med Imaging Graph ; 33(4): 317-24, 2009 Jun.
Article in English | MEDLINE | ID: mdl-19304453

ABSTRACT

The intima-media thickness (IMT) of the common carotid artery (CCA) is widely used as an early indicator of cardiovascular disease (CVD). It was proposed but not thoroughly investigated that the composition and texture of the media layer (ML) can be used as an indicator for the risk of stroke. In this study, we investigate the application of texture analysis of the ML of the CCA and how texture is affected by age and gender. The study was performed on 100 longitudinal-section ultrasound images acquired from asymptomatic subjects at risk of atherosclerosis. The images were separated into three different age groups, namely below 50, 50-60, and above 60 years old. Furthermore, the images were separated according to gender. A total of 61 different texture features were extracted from the intima layer (IL), the ML, and the intima-media complex (IMC). The ML and the IMC were segmented manually by a neurovascular expert and also automatically by a snakes segmentation system. We have found that male patients tended to have larger media layer thickness (MLT) values as compared to the MLT of female patients of the same age. We have found significant differences among texture features extracted from the IL, ML and IMC from different age groups. Furthermore, for some texture features, we found that they follow trends that correlate with a patient's age. For example, the gray-scale median GSM of the ML falls linearly with increasing MLT and with increasing age. Our findings suggest that ultrasound image texture analysis of the media layer has potential as an assessment biomarker for the risk of stroke.


Subject(s)
Aging/physiology , Carotid Artery, Common/diagnostic imaging , Carotid Artery, Common/physiology , Echocardiography/methods , Image Interpretation, Computer-Assisted/methods , Tunica Intima/diagnostic imaging , Age Factors , Aged , Aged, 80 and over , Female , Humans , Middle Aged , Reproducibility of Results , Sensitivity and Specificity , Sex Factors , Statistics as Topic
20.
J Electromyogr Kinesiol ; 19(1): 157-71, 2009 Feb.
Article in English | MEDLINE | ID: mdl-17544702

ABSTRACT

The objective of this study was to compute reference SEMG values for normal subjects of 13 parameters extracted in the time, frequency and bispectrum domain, from the Biceps Brachii (BB) muscle generated under isometric voluntary contraction (IVC). SEMG signals were recorded from 94 subjects for 5s at 10, 30, 50, 70 and 100% of maximum voluntary contraction (MVC). The Wilcoxon signed rank test was applied to detect significant differences or not at p<0.05 between force levels for each of the 13 parameters. The main findings of this study can be summarized as follows: (i) The time domain parameters turns per second and number of zero crossings per second increase significantly with force level. (ii) The power spectrum median frequency parameter decreases significantly with force level, whereas maximum power and total power increase significantly with force level. (iii) The bispectrum parameter, maximum amplitude, increases significantly with force level with the exception the transition from 30% to 50% MVC. Although, the tests for Gaussianity and linearity show no significant difference with force level, the SEMG signal exhibits a more Gaussian distribution with increase of force up to 70% MVC. The SEMG linearity test, which is a measure of how constant the bicoherence index is in the bi-frequency domain, shows that the signal's bicoherence index is less constant (hence, the signal is less linear) at 70% of MVC compared to 10, 30, 50 and 100% MVC. (iv) The time domain parameters have good correlation between them as well as, between each one of them and maximum and total power. The median frequency has a good (negative) correlation with the bispectrum peak amplitude. (v) No significant differences exist between values based on gender or age. The findings of this study can further be used for the assessment of subjects suffering with neuromuscular disorders, or in the rehabilitation laboratory for monitoring the elderly or the disabled, or in the occupational medicine laboratory.


Subject(s)
Electromyography , Isometric Contraction , Muscle, Skeletal/physiology , Signal Processing, Computer-Assisted , Adolescent , Adult , Aged , Arm , Child , Child, Preschool , Female , Humans , Male , Middle Aged , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...