Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Min Metall Explor ; 37(4): 1055-1064, 2020 Mar 03.
Article in English | MEDLINE | ID: mdl-32875279

ABSTRACT

The National Institute for Occupational Safety and Health (NIOSH) and the former U.S. Bureau of Mines (USBM) have given a significant effort over the past four decades in researching and developing engineering controls and interventions to reduce mine workers' dust exposures during the bagging and palletizing of industrial minerals. Workers performing manual bagging and palletizing of 50- to 100-pound bags typically have some of the highest dust exposures of all workers at mining and mineral processing operations. This paper will provide an overview of available dust control technologies for bagging operations and present the findings of a recent case study that was conducted at four different industrial sand operations to identify the current types of bagging and palletizing technologies being used and to evaluate their effectiveness in reducing workers' exposures to respirable crystalline silica dust. An evaluation will also be performed to determine if further reductions in respirable dust levels can be achieved by incorporating additional modifications or improvements into the existing technology.

3.
Min Metall Explor ; 36(4): 741-749, 2019 Aug.
Article in English | MEDLINE | ID: mdl-31768501

ABSTRACT

Video techniques for monitoring exposure, such as NIOSH's "Helmet-CAM," employ both real-time dust monitors and mobile video cameras to assess workers' respirable dust exposures. Many real-time personally worn dust monitors utilize light scattering sensing elements, which are subject to measurement biases as a function of dust type (size, composition, shape factor) and environmental conditions such as relative humidity. These biased and inaccurate dust measurements impair the monitor's ability to properly represent actual respirable dust concentrations. In the testing described, instrument mass concentration data was collected using three different types of commonly used commercial off-the-shelf personal dust monitors and compared to a reference standard. This testing was performed in a calm air (Marple) dust chamber in which three units of each make and model (for a total of nine monitors) were used for each test. Equivalency factors (EF, a multiplier to match the Thermo TEOM 1400a reference instrument) ranged between 0.746 and 1.879 across all dusts and environmental conditions tested, and between 0.821 and 1.519 on the ISO test dust.

4.
J Occup Environ Hyg ; 14(5): 323-334, 2017 05.
Article in English | MEDLINE | ID: mdl-27792474

ABSTRACT

Airborne coal dust generated during mining can deposit and accumulate on mine surfaces, presenting a dust explosion hazard. When assessing dust hazard mitigation strategies for airborne dust reduction, sampling is done in high-velocity ventilation air, which is used to purge the mining face and gallery tunnel. In this environment, the sampler inlet velocity should be matched to the air stream velocity (isokinetic sampling) to prevent oversampling of coarse dust at low sampler-to-air velocity ratios. Low velocity ratios are often encountered when using low flow rate, personal sampling pumps commonly used in underground mines. In this study, with a goal of employing mine-ready equipment, a personal sampler was adapted for area sampling of coarse coal dust in high-velocity ventilation air. This was done by adapting an isokinetic nozzle to the inlet of an Institute of Occupational Medicine (Edinburgh, Scotland) sampling cassette (IOM). Collected dust masses were compared for the modified IOM isokinetic sampler (IOM-MOD), the IOM without the isokinetic nozzle, and a conventional dust sampling cassette without the cyclone on the inlet. All samplers were operated at a flow rate typical of personal sampling pumps: 2 L/min. To ensure differences between collected masses that could be attributed to sampler design and were not influenced by artifacts from dust concentration gradients, relatively uniform and repeatable dust concentrations were demonstrated in the sampling zone of the National Institute for Occupational Safety and Health experimental mine gallery. Consistent with isokinetic theory, greater differences between isokinetic and non-isokinetic sampled masses were found for larger dust volume-size distributions and higher ventilation air velocities. Since isokinetic sampling is conventionally used to determine total dust concentration, and isokinetic sampling made a difference in collected masses, the results suggest when sampling for coarse coal dust the IOM-MOD may improve airborne coarse dust assessments over "off-the-shelf" sampling cassettes.


Subject(s)
Coal Mining , Coal/analysis , Dust/analysis , Environmental Monitoring/methods , Occupational Health , Equipment Design , Explosions/prevention & control , Humans , Particle Size , Ventilation
SELECTION OF CITATIONS
SEARCH DETAIL
...